Purpose:To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation in patients with keratoconus using a mechanical implantation technique.Materials and Methods:Thirty eyes of 17 patients with keratoconus were enrolled. ICRSs (Keraring) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3-, 6-, and 12-month follow-ups were completed, and statistical analysis was performed.Results:The mean preoperative UDVA for all eyes was 1.36 ± 0.64 logMAR. At 12 months, the mean UDVA was 0.51 ± 0.28 logMAR (P = 0.001), and the mean preoperative CDVA was 0.57 ± 0.29 logMAR, which improved to 0.23 ± 0.18 (P = 0.001) at 1 year. There was a significant reduction in spherical equivalent refractive error from –6.42 ± 4.69 diopters (D) preoperatively to –1.26 ± 1.45 D (P = 0.001) at 1 year. In the same period, the mean K-readings improved from 49.38 ± 3.72 D to 44.43 ± 3.13 D (P = 0.001), and the mean ISAI improved from 7.92 ± 3.12 to 4.21 ± 1.96 (P = 0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during and or after surgery.Conclusion:ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for keratoconus. All parameters improved by the 1-year follow-up.
A 26-year-old man with degenerative high myopia had bilateral anterior chamber phakic intraocular lens (IOL) implantation under general anesthesia. The preoperative slitlamp examination was normal. No mydriatic drops were used before, during, or after the procedure. Postoperatively, the intraocular pressure (IOP) in the right globe increased to 60 mm Hg. After the IOP was controlled, the pupil became fixed and dilated. Iris fluorescein angiography was obtained and delayed filling of the iris capillary plexus with large areas of no perfusion was observed in the right eye. Based on these findings, a diagnosis of Urrets-Zavalia syndrome was made. To our knowledge, this is the first report of Urrets-Zavalia syndrome after phakic IOL implantation.
Torsional phacoemulsification performed with a 45-degree aperture angled tip provided more effective lens removal with a lower CDE and less CCT change than a 30-degree aperture angled tip.
PurposeThe aim of the study was to statistically compare intraocular pressure (IOP) values measured using noncontact tonometer (NCT), Goldmann applanation tonometry (GAT) with fluorescein (fGAT), and GAT without fluorescein (nGAT). The study was also performed to test whether the values obtained using each technique change in accordance with the central corneal thickness (CCT) and refractive and keratometric values.Study designThis study was a prospective study of 188 eyes of 94 healthy volunteers. Methods: IOP was measured using fGAT, nGAT and NCT. CCT, refractive values, and keratometric values were measured, and the correlations and differences in the IOP for each tonometer were investigated.ResultsThe mean IOP values obtained with the NCT, nGAT, and fGAT were 17.5±3.7, 12.3±2.7, and 12.5±2 mmHg. The mean CCT was 538.2±34.4 µm, the mean refractive value was 0.9±1.2 D, and the mean keratometric value was 43.5±1.5 D. NCT was positively correlated with fGAT and GAT values and was significantly higher than both the values. There were no differences between fGAT and GAT values. No correlation was observed between the CCT and keratometric and refractive values and the difference between NCT and nGAT or fGAT.ConclusionDifferences in the measurements obtained using nGAT and fGAT were insignificant (P>0.05). Both values were positively correlated with NCT measurements (r =0.354, P<0.05) and were independent of CCT, keratometry, and refraction values. nGAT appears to be suitable for use in routine clinic practice.
Aim:To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique.Materials and Methods:Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring segments (ICRS) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric (K) readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3, 6, and 12-month follow-ups were completed, and statistical analysis was performed.Results:The mean preoperative UDVA for all eyes was 1.28 ± 0.59 logMAR. At 12 months, the mean UDVA was 0.36 ± 0.19 logarithm of the Minimum Angle of Resolution (logMAR) (P=0.002), and the mean preoperative CDVA was 0.58 ± 0.3 logMAR, which improved to 0.15 ± 0.12 (P=0.002) at 1 year. There was a significant reduction in cylindrical refractive and spherical equivalent refractive error from –5.29 ± 2.47 diopters (D) and –5.54 ± 5.04 D preoperatively to –1.47 ± 0.71 D and –0.74 ± 1.07 D (P=0.001, P=0.002), respectively, at 1 year. In the same period, the mean K- readings improved from 47.93 ± 4.84 D to 40.87 ± 2.36 D (P=0.002), and the mean ISAI improved from 5.34 ± 3.05 to 2.37 ± 1.68 (P=0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during or after surgery.Conclusion:ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for post-LASIK ectasia. All parameters showed improvement at 1-year follow-up.
Importance. There is a conflict about the content of the macular folds in nanophthalmic eyes in the literature. Our study clearly demonstrated that papillomacular folds seen in nanophthalmos or posterior microphthalmos were only composed of neurosensory retina without involvement of retinal pigment epithelium and choroid. Observations. This is a report of two consecutive nanophthalmic patients with macular folds at Maltepe University School of Medicine, Department of Ophthalmology, from January to June 2012. Anterior segment dimensions were near normal. The axial lengths of the eyes were short with markedly shortened posterior segment. A macular fold extending from the center of the fovea towards the optic nerve head was present in all eyes. Optic coherence tomography clearly demonstrated that folds were only composed of neurosensory retina. Binocular visual acuities and refractive errors of the cases were 0.3, 0.2 and +16.00, +15.75 diopters, respectively. Conclusions and Relevance. Our study proposes a surgical option to treat these folds like serous retinal detachments by showing the true content of the folds, although there is not any surgical operation accepted for this condition yet. Further studies dealing with the surgical interventions of these folds should be performed to support this option.
Torsional phacoemulsification performed with 22-degree bent tips provided more effective lens removal than 12-degree bent tips, with a lower UST and CDE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.