INTRODUÇÃO Edema macular (EM) permanece sendo a causa mais frequente de baixa visão após cirurgia de catarata (1,2). O EM desenvolve-se devido à quebra da barreira hematorretiniana causando acúmulo de líquido no espaço extracelular da retina e formação de cistos nas camadas plexiforme externa e nuclear interna (3,4). A incidência de EM à angiografia (3-70%) e de EM clinicamente relevante (0-22%) variam substancialmente na literatura, dependen-do da sua definição, técnica da cirurgia, método diagnóstico utilizado e comorbidades associadas (1,2,5-7). A incidência de EM pós-operatório aumenta quando a cirurgia de catarata é acompanhada no intraoperatório de rotura de cápsula RESUMO Objetivo: Avaliar o edema macular após cirurgia não complicada de facoemulsi-ficação com implante de lente intraocular por meio da tomografia de coerência óptica spectral domain (OCT-SD). Métodos: Foi realizado estudo prospectivo em 62 olhos de pacientes submetidos à facoemulsificação com implante de lente intraocular. Os pacientes foram avaliados antes e após a cirurgia, no primeiro dia, e na primeira, segunda e quarta semanas. Acuidade visual (AV), células na câmara anterior e tomografia de coerência óptica macular cubo 200x200 foram medidos. Resultados: Após a cirurgia de facoemulsificação houve melhora da acuidade visual, inflamação decrescente, e a espessura e o volume macular aumentaram. Ocorreu um caso de edema macular cistoide. Houve correlação inversa fraca entre a acuidade visual e a espessura macular central, e entre a acuidade visual e o volume macular. Foi observada correlação direta fraca entre a inflamação e o volume macular. Conclusão: Edema macular subclínico desenvolve-se mesmo após cirurgia de catarata não complicada em pacientes não predispostos. A tomografia de coerência óptica spectral domain foi capaz de detectar pequenos aumentos na espessura macular no período avaliado. Descritores: Facoemulsificação; Edema macular; Tomografia de coerência óptica; Implante de lente intraocular; Período pós-operatório; Acuidade visual ABSTRACT Purpose: To evaluate macular edema after uncomplicated phacoemulsification with implantation of intraocular lens by spectral domain optical coherence tomography (OCT). Methods: Prospective study was conducted in 62 eyes of patients underwent phaco-emulsification with implantation of intraocular lens. Patients were evaluated before surgery and after surgery at day 1, week 1, week 2 and week 4. Visual acuity (VA), anterior chamber cells and 200x200 macular cube optical coherence tomography were measured. Results: After phacoemulsification there was an improvement in visual acuity, de creasing inflammation, and increased macular thickness and macular volume. There was one case of cystoid macular edema. There was a weak inverse correlation between visual acuity and central macular thickness, and between visual acuity and macular volume. We observed a week direct correlation between inflammation and macular volume. Conclusion: Subclinical macular edema develops even after uncomplicated cataract s...
The short-term safety and efficacy of intraocular, epiretinal delivery of beta radiation for the treatment of subfoveal choroidal neovascularization was promising in this small study group and should be studied in a larger cohort of patients.
Twenty-five-gauge sutureless vitrectomy with straight incisions resulted in a hypotony rate of 26.12% at 2 hours that decreased to 17.11% on day 1 and to 8.10% at week 1 but did not increase the incidence of postoperative complications.
Pars plana vitrectomy and 1,000 centistokes silicone oil injection with 25-gauge system is feasible in diabetic tractional retinal detachment even in complex cases. Indications of 25-gauge surgery may be expanded toward this area.
Secondary iris claw intraocular lens implantation is clinically safe and effective to correct aphakia in vitrectomized eyes without capsular support. Larger studies with longer follow-up are warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.