Long-term neuroprostheses for functional electrical stimulation must efficiently stimulate tissue without electrolyzing water and raising the extracellular pH to toxic levels. Comparison of the stimulation efficiency of tungsten wire electrodes (W wires), platinum microelectrode arrays (PtMEA), as-grown vertically aligned carbon nanofiber microbrush arrays (VACNF MBAs), and polypyrrole coated (PPy-coated) VACNF MBAs in eliciting field potentials in the hippocampus slice indicates that, at low stimulating voltages that preclude the electrolysis of water, only the PPy-coated VACNF MBA is able to stimulate the CA3 to CA1 pathway. Unlike the W wires, PtMEA, as-grown VACNF MBA, and the PPy-coated VACNF MBA elicit only excitatory postsynaptic potentials (EPSPs). Furthermore, the PPy-coated VACNF MBA evokes somatic action potentials in addition to EPSPs. These results highlight the PPy-coated VACNF’s advantages in lower electrode impedance, ability to stimulate tissue through a biocompatible chloride flux, and stable vertical alignment in liquid that enables access to spatially confined regions of neuronal cells.
We report the stimulation, recording, and voltage clamp of muscle fibers using a 30 nm diameter single multiwalled carbon nanotube electrode (sMWNT electrode) tip. Because of the lower access resistance, the sMWNT electrode conducts extracellular and intracellular stimulation more efficiently compared to glass micropipettes. The sMWNT electrode records field potentials and action potentials and performs whole cell voltage clamping of single fibers.
Identifying the neurophysiological basis underlying learning and memory in the mammalian central nervous system requires the development of biocompatible, high resolution, low electrode impedance electrophysiological probes; however, physically, electrode impedance will always be finite and, at times, large. Herein, we demonstrate through experiments performed on frog sartorius muscle that single multi-walled carbon nanotube electrode (sMWNT electrode) geometry and placement are two degrees of freedom that can improve biocompatibility of the probe and counteract the detrimental effects of MWNT/electrolyte interface impedance on the stimulation efficiency and signal-to-noise ratio (SNR). We show that high aspect ratio dependent electric field enhancement at the MWNT tip can boost stimulation efficiency. Derivation of the sMWNT electrode's electrical equivalent indicates that, at low stimulus voltage regimes below 1 V, current conduction is mediated by charge fluctuation in the double layer obviating electrolysis of water, which is potentially toxic to pH sensitive biological tissue. Despite the accompanying increase in electrode impedance, a pair of closely spaced sMWNT electrodes in a two probe (bipolar) configuration maintains biocompatibility and enhances stimulation efficiency and SNR compared to the single probe (unipolar) configuration. For stimulus voltages below 1 V, the electrical equivalent verifies that current conduction in the two probe configuration still proceeds via charge fluctuation in the double layer. As an extracellular stimulation electrode, the two sMWNT electrodes comprise a current dipole that concentrates the electric field and the current density in a smaller region of sartorius; consequently, the bipolar configuration can elicit muscle fiber twitching at low voltages that preclude electrolysis of water. When recording field potentials, the bipolar configuration subtracts the potential between two points allowing for the detection of higher signal amplitudes. As a result, SNR is improved. These results indicate that use of the high aspect ratio MWNT in a bipolar configuration can achieve a biocompatible electrode that offers enhanced stimulation efficiency and higher SNR.
We report the irreversible structural failure of individual multiwalled carbon nanotube (MWNT) tips after water submersion. We used 11 individual MWNTs with varying geometries and showed length dependent MWNT failure with scanning electron microscopy. Shorter MWNTs are more likely to survive penetration of the water-air interface. We observed the bending of MWNT probes on the water surface using optical microscopy. Surface tension force acting on MWNTs at the water-air interface was calculated. Compared to shorter MWNTs, the calculations suggest that longer MWNTs exert a smaller bending restoring force with respect to surface tension force, leading to MWNT bending until failure.
We report the application of a sensor with a multielectrode architecture consisting of four single multiwalled carbon nanotube electrodes (sMWNT electrodes) with nanotube tip diameters of approximately 30 nm to stimulation, recording, and bioimpedance characterization of whole muscle. Parallel pairs of sMWNT electrodes achieve improved stimulation efficiency from a reduction in electrode impedance and enhanced signal-to-noise ratio by detecting endogenic signals from a larger population of electrically active cells. The sensor with a four sMWNT electrode configuration can monitor changes in whole tissue bioimpedance.
We present the electrical monitoring of cultured living neural cells using vertically aligned carbon nanotubes (CNT) as an extracellular electrode material in a microelectrode array (MEA). The carbon nanotubes are grown using plasma enhanced chemical vapor deposition (PECVD) resulting in 3-18 µ µ µ µm long nanotubes with diameters of 10-40 nm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.