Original PaperComparison of sample preparation methods combined with fast gas chromatography -mass spectrometry for ultratrace analysis of pesticide residues in baby food Four sample preparation techniques were compared for the ultratrace analysis of pesticide residues in baby food: (a) modified Schenck's method based on ACN extraction with SPE cleaning; (b) quick, easy, cheap, effective, rugged, and safe (QuEChERS) method based on ACN extraction and dispersive SPE; (c) modified QuEChERS method which utilizes column-based SPE instead of dispersive SPE; and (d) matrix solid phase dispersion (MSPD). The methods were combined with fast gas chromatographic-mass spectrometric analysis. The effectiveness of clean-up of the final extract was determined by comparison of the chromatograms obtained. Time consumption, laboriousness, demands on glassware and working place, and consumption of chemicals, especially solvents, increase in the following order QuEChERS a modified QuEChERS a MSPD a modified Schenck's method. All methods offer satisfactory analytical characteristics at the concentration levels of 5, 10, and 100 lg/kg in terms of recoveries and repeatability. Recoveries obtained for the modified QuEChERS method were lower than for the original QuEChERS. In general the best LOQs were obtained for the modified Schenck's method. Modified QuEChERS method provides 21 -72% better LOQs than the original method.
Isotachophoresis (ITP) was applied for the determination of some antirheumatic drugs (fenoprofen, naproxen, ibuprofen, and ketoprofen) in human serum. The leading electrolyte contained hydrochloric acid (10 mmol x L(-1)), creatinine (pH 4.5) and methylhydroxyethyl cellulose (0.1%). The terminating electrolyte was 2-(N-morpholino)ethanesulfonic acid (10 mmol x L(-1)) adjusted with tris(hydroxymethyl)aminomethane to pH 6.9. The ITP separations were carried out in column-coupling configuration of the separation unit provided with a preseparation column of 160 x 0.8 mm inner diameter (ID) and analytical column of 160 x 0.3 mm ID. The limit of detection for ibuprofen, fenoprofen, and naproxen in serum by direct sampling was 0.008, 0.005 and 0.004 mmol x L(-1). The limit of detection for ketoprofen in serum after ethanol precipitation was 0.001 mmol x L(-1).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.