2014
DOI: 10.1155/2014/785914
|View full text |Cite
|
Sign up to set email alerts
|

FTIR Spectroscopy Combined with Partial Least Square for Analysis of Red Fruit Oil in Ternary Mixture System

Abstract: FTIR spectroscopy is a promising method for quantification of edible oils. Three edible oils, namely, red fruit oil (RFO), corn oil (CO), and soybean oil (SO), in ternary mixture system were quantitatively analyzed using FTIR spectroscopy in combination with partial least square (PLS). FTIR spectra of edible oils in ternary mixture were subjected to several treatments including normal spectra and their derivative. Using PLS calibration, the first derivative FTIR spectra can be exploited for determination of RF… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(16 citation statements)
references
References 18 publications
0
16
0
Order By: Relevance
“…is technique, integrated with statistical approach particularly partial least squares (PLS), has demonstrated promising sensitivity for adulterant analysis [12,13,14]. FTIR coupled with PLS has been used for detection of adulterants in edible oils including avocado oil, sunflower oil, and palm oil with a detection limit as low as 2-3% [15,16,17].…”
Section: Introductionmentioning
confidence: 99%
“…is technique, integrated with statistical approach particularly partial least squares (PLS), has demonstrated promising sensitivity for adulterant analysis [12,13,14]. FTIR coupled with PLS has been used for detection of adulterants in edible oils including avocado oil, sunflower oil, and palm oil with a detection limit as low as 2-3% [15,16,17].…”
Section: Introductionmentioning
confidence: 99%
“…Fig. 3 shows the first derivative treatment to the spectra at 1.200-1.000 cm -1 , this treatment removes baseline shifts and improves the accuracy of quantification [34].…”
Section: The Wavenumbers Marked With Bold Was Preferred For Predictionmentioning
confidence: 99%
“…Similar structures of both compounds make similar interaction with near infrared radiation. However, there are no exactly same spectra resulted in vibrational spectroscopy since each compound in the sample would interact uniquely with near infrared radiation [19]. The optimum PLS model established exploited single wavenumber region of 4000-6500 cm -1 although previous research applied different wavenumber region of 4035-6934 cm -1 [15] to the simultaneous determination of stevioside and rebaudioside A. PLS regression not only sensitive to a particular region but also a number of components, N, used to calculate PLS parameters.…”
Section: Simultaneous Calibration Of Rebaudioside a Stevioside And mentioning
confidence: 99%