Objectives: Intraoperative tumor visualization with 5-aminolevulinic acid (5-ALA) induced protoporphyrin IX (PpIX) fluorescence is widely applied for improved resection of high-grade gliomas. However, visible fluorescence is present only in a minority of low-grade gliomas (LGGs) according to current literature. Nowadays, antiepileptic drugs (AEDs) are frequently administered to LGG patients prior to surgery. A recent in-vitro study demonstrated that AEDs result in significant reduction of PpIX synthesis in glioma cells. The aim of this study was thus to investigate the role of 5-ALA fluorescence in LGG surgery and the influence of AEDs on visible fluorescence. Patients and Methods: Patients with resection of a newly diagnosed suspected LGG after 5-ALA (25 mg/kg) administration were initially included. During surgery, the presence of visible fluorescence (none, mild, moderate, or bright) within the tumor and intratumoral fluorescence homogeneity (diffuse or focal) were analyzed. Tissue samples from fluorescing and/or non-fluorescing areas within the tumor and/or the assumed tumor border were collected for histopathological analysis (WHO tumor diagnosis, cell density, and proliferation rate). Only patients with diagnosis of LGG after surgery remained in the final study cohort. In each patient, the potential preoperative intake of AEDs was investigated. Results: Altogether, 27 patients with a histopathologically confirmed LGG (14 diffuse astrocytomas, 6 oligodendrogliomas, 4 pilocytic astrocytomas, 2 gemistocytic astrocytomas, and one desmoplastic infantile ganglioglioma) were finally included. Visible fluorescence was detected in 14 (52%) of 27. In terms of fluorescence homogeneity ( n = 14), 7 tumors showed diffuse fluorescence, while in 7 gliomas focal fluorescence was noted. Cell density ( p = 0.03) and proliferation rate ( p = 0.04) was significantly higher in fluorescence-positive than in fluorescence-negative samples. Furthermore, 15 (56%) of 27 patients were taking AEDs before surgery. Of these, 11 patients (73%) showed no visible fluorescence. In contrast, 10 (83%) of 12 patients without prior AEDs intake showed visible fluorescence. Thus, visible fluorescence was significantly more common in patients without AEDs compared to patients with preoperative AED intake (OR = 0,15 (CI 95% 0.012–1.07), p = 0.046). Conclusions: Our study shows a markedly higher rate of visible fluorescence in a series of LGGs compared to current literature. According to our preliminary data, preoperative intake of AEDs seems to reduce the presence of visible fluorescence in such tumors and should thus be taken into account in the clinical setting.
5-aminolevulinic acid (5-ALA) is a natural precursor of protoporphyrin IX (PP IX), which possesses fluorescent properties and is more intensively accumulated in tumor cells than in normal tissue. Therefore, the use of 5-ALA in the surgical treatment of intracranial tumors, particularly gliomas, has gained popularity in the last years, whereas its use in other intracranial pathological entities including meningiomas has been reported occasionally. This study describes a series of 28 patients with intracranial meningiomas, who were administered 5-ALA for a better visualization of tumor boundaries. Twelve patients underwent also laser spectroscopic analysis in order to confirm the visual impression of tumor tissue visualization. Bone infiltration was readily demonstrated. In one case, the tumor recurrence could have been prevented by removal of a tumor remnant, which would possibly have been better recognized if spectroscopic analysis had been used. Fluorescent navigation (FN) is a useful method for maximizing the radicality of meningioma surgery, particularly if the tumor infiltrates the bone, the skull base, and/or the surrounding structures
Appropriate analysis of biological tissue deep regions is important for tumor targeting. This paper is concentrated on photons’ paths analysis in such biotissue as brain, because optical probing depth of fluorescent and excitation radiation differs. A method for photon track reconstruction was developed. Images were captured focusing on the transparent wall close and parallel to the source fibres, placed in brain tissue phantoms. The images were processed to reconstruct the photons most probable paths between two fibres. Results were compared with Monte Carlo simulations and diffusion approximation of the radiative transfer equation. It was shown that the excitation radiation optical probing depth is twice more than for the fluorescent photons. The way of fluorescent radiation spreading was discussed. Because of fluorescent and excitation radiation spreads in different ways, and the effective anisotropy factor,geff, was proposed for fluorescent radiation. For the brain tissue phantoms it were found to be0.62±0.05and0.66±0.05for the irradiation wavelengths 532 nm and 632.8 nm, respectively. These calculations give more accurate information about the tumor location in biotissue. Reconstruction of photon paths allows fluorescent and excitation probing depths determination. Thegeffcan be used as simplified parameter for calculations of fluorescence probing depth.
The neurosurgery of intracranial tumors is often complicated by the difficulty of distinguishing tumor center, infiltration area, and normal tissue. The current standard for intraoperative navigation is fluorescent diagnostics with a fluorescent agent. This approach can be further enhanced by measuring the Raman spectrum of the tissue, which would provide additional information on its composition even in the absence of fluorescence. However, for the Raman spectra to be immediately helpful for a neurosurgeon, they must be additionally processed. In this work, we analyzed the Raman spectra of human brain glioblastoma multiforme tissue samples obtained during the surgery and investigated several approaches to dimensionality reduction and data classificatin to distinguish different types of tissues. In our study two approaches to Raman spectra dimensionality reduction were approbated and as a result we formulated new technique combining both of them: feature filtering based on the selection of those shifts which correspond to the biochemical components providing the statistically significant differences between groups of examined tissues (center of glioblastoma multiforme, tissues from infiltration area and normally appeared white matter) and principal component analysis. We applied the support vector machine to classify tissues after dimensionality reduction of registered Raman spectra. The accuracy of the classification of malignant tissues (tumor edge and center) and normal ones using the principal component analysis alone was 83% with sensitivity of 96% and specificity of 44%. With a combined technique of Frontiers in Oncology frontiersin.org 01
Cholangiocellular cancer (CCC) is a malignant neoplasm of the hepatobiliary system that is difficult to diagnose and treat. Currently, the most effective treatment of CCC is demonstrated under the control by fluorescent diagnosis. Photodynamic therapy (PDT) has also shown good results in the treatment of this disease, and fluorescence analysis of the photosensitizer is a good approach to control PDT. This article presents the results of a comparison of spectroscopic and quantitative video-fluorescent analysis of chlorin e6 photosensitizer fluorescence in vivo during cholangiocellular cancer surgery. Spectroscopic analysis provides accurate information about the concentration of the photosensitizer in the tumor, while the video-fluorescence method is convenient for visualizing tumor margins. A direct correlation is shown between these two methods when comparing the fluorescence signals before and after PDT. The applied paired Student’s t-test shows a significant difference between fluorescence signal before and after PDT in both diagnostic methods. In this regard, video-fluorescence navigation is not inferior in accuracy, sensitivity, or efficiency to spectroscopic methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.