A label-free optical biosensor is described that employs a silicon-based high-contrast grating (HCG) resonator with a spectral linewidth of ~500 pm that is sensitive to ligand-induced changes in surface properties. The device is used to generate thermodynamic and kinetic data on surface-attached antibodies with their respective antigens. The device can detect serum cardiac troponin I, a biomarker of cardiac disease to 100 pg/ml within 4 mins, which is faster, and as sensitive as current enzyme-linked immuno-assays for cTnI.
We have developed a microelectromechanical system (MEMS) optical phased array incorporating a high-index-contrast subwavelength grating (HCG) for beamforming and beamsteering in a range of ± 1.26° × 1.26°. Our approach needs only a thin single-layer HCG made of silicon, considerably improving its speed thanks to the low mass, and is suitable for high optical power applications. The measured resonant frequency of HCG is 0.32 MHz.
We report a high speed 8x8 optical phased array using tunable 1550 nm all-pass filters with ultrathin high contrast gratings (HCGs) as the microelectromechanical-actuated top reflectors. The all-pass filter design enables a highly efficient phase tuning (1.7 π) with a small actuation voltage (10 V) and actuation displacement of the HCG (50 nm). The microelectromechanical HCG structure facilitates a high phase tuning speed >0.5 MHz. Beam steering is experimentally demonstrated with the optical phased array.
We report on microelectromechanical systems (MEMS)-actuated 32 × 32 optical phased arrays (OPAs) with high fill-factors and microsecond response time. To reduce the mirror weight and temperature-dependent curvature, we use high-contrast-grating (HCG) mirrors comprising a single layer of sub-wavelength polysilicon gratings with 400 nm thickness, 1250 nm pitch, and 570 nm grating bar width. The mirror has a broad reflection band and a peak reflectivity of 99.9% at 1550 nm wavelength. With 20 × 20 μm2 pixels and 2 μm, the OPA has a total aperture of 702 × 702 μm2 and a fill factor of 85%. The OPA is electrostatically controlled by voltage and has a total field of view of ± 2°, an instantaneous field of view (beam width) of 0.14°, and a response time of 3.8 μs. The latter agrees well with the mechanical resonance frequency of the HCG mirror (0.42 MHz).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.