An in situ straining holder capable of tensile deformation and high-angle tilt for electron tomography was developed for polymeric materials. The holder has a dedicated sample cartridge, on which a variety of polymeric materials, such as microtomed thin sections of bulk specimens and solvent-cast thin films, can be mounted. Fine, stable control of the deformation process with nanoscale magnification was achieved. The holder allows large tensile deformation (≃800 μm) with a large field of view (800 × 200 μm before the deformation), and a high tilt angle (±75°) during in situ observations. With the large tensile deformation, the strain on the specimen can be as large as 26, at least one order of magnitude larger than the holder's predecessor. We expect that meso- and microscopic insights into the dynamic mechanical deformation and fracture processes of polymeric materials can be obtained by combining the holder with a transmission electron microscope equipped with an energy filter. The filter allows zero-loss imaging to improve the resolution and image contrast for thick specimens. We used this technique to study the deformation process in a silica nanoparticle-filled isoprene rubber.
Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.
This paper reports the preliminary results of a new in-situ three-dimensional (3D) imaging system for observing plastic deformation behavior in a transmission electron microscope (TEM) as a directly relevant development of the recently reported straining-and-tomography holder [Sato K et al. (2015) Development of a novel straining holder for transmission electron microscopy compatible with single tilt-axis electron tomography. Microsc. 64: 369-375]. We designed an integrated system using the holder and newly developed straining and image-acquisition software and then developed an experimental procedure for in-situ straining and time-resolved electron tomography (ET) data acquisition. The software for image acquisition and 3D visualization was developed based on the commercially available ET software TEMographyTM. We achieved time-resolved 3D visualization of nanometer-scale plastic deformation behavior in a Pb-Sn alloy sample, thus demonstrating the capability of this system for potential applications in materials science.
Procalcitonin (PCT), a widely used biomarker for bacterial infections, is sometimes measured in convulsion patients to distinguish bacterial infections including bacterial meningitis. However, serum PCT elevation is reported in several other conditions. This study assessed the diagnostic value of serum PCT concentrations in convulsion patients. This study examined a convulsion group: patients admitted to our critical care center during April 2018 through September 2019 via the emergency department presenting with convulsions. Randomly sampled patients admitted without convulsions were categorized as a non-convulsion group. Serum PCT analysis was performed with consideration of whether or not the patient had an infection. Diagnostic values of serum PCT for bacterial infection were evaluated for convulsion and non-convulsion patients using the positive likelihood ratio of PCT. This study found 84 patients as eligible for the convulsion group; 1:2 matched 168 control patients were selected as non-convulsion group members. The positive likelihood ratio for bacterial infection was found to be significantly lower in the convulsion group than in the control group (1.94 vs. 2.65) when setting the positive cut-off for PCT as 0.5 ng/mL. Convulsion patients had a higher PCT value. The positive likelihood ratio for patients without bacterial infection was lower.
Measuring atomic positions in-situ under an external electric field can provide important insights into the structure-property relationship of electronic materials. In this paper, we demonstrate picometer level accuracy and precision of atomic positions in single-crystalline SrTiO3 under an electric field through annular dark-field scanning transmission electron microscopy. By carrying out electrical biasing in-situ electron microscopy at the atomic scale, the lattice constant was measured with a precision of 9.0 pm under an electric field of ±0.57 kV/cm. In addition, the Ti position in the SrTiO3 unit cell was measured with an accuracy of 20.0 pm at a confidence level of greater than 93%. This opens up a possibility of characterizing functional electronic devices at atomic resolution under operative conditions.
In conventional transmission electron microscopy, specimens to be observed are placed in between the objective lens pole piece and therefore exposed to a strong magnetic field about 2 T. For a ferromagnetic specimen, magnetization of the specimen causes isotropic and anisotropic defocusing, deflection of the electron beam as well as deformation of the specimen, which all become more severe when the specimen tilted. Therefore electron tomography on a ferromagnetic crystalline specimen is highly challenging because tilt-series data sets must be acquired without changing the excitation condition of a specific diffraction spot. In this study, a scanning transmission electron microscopy (STEM) tomography method without magnetizing a ferromagnetic specimen has been developed for three-dimensional (3D) visualization of dislocations in α-Fe, which is a typical ferromagnetic material. Magnetic-field-free environment down to 0.38 ± 0.07 mT at the specimen position is realized by demagnetizing the objective lens pole piece of a commercial STEM instrument. By using a spherical aberration corrector with the magnetic-field-free environment, an "aberration corrected Low-Mag STEM mode" with no objective lens field reaches a convergence semi angle ∼1 mrad and a spatial resolution ∼5 nm, and shows an adequate performance of imaging dislocations under a two-beam excitation condition for a low-index diffracted beam. The illumination condition for the aberration corrected Low-Mag STEM mode gives no overlap between the direct beam disk (spot) and neighboring diffraction disks. An electron channeling contrast imaging technique, in which an annular detector was located at a doughnut area between the direct beam and the neighboring diffracted beams, was effectively employed with the aberration corrected Low-Mag STEM mode to keep image intensity high enough even at large specimen-tilt angles. The resultant tomographic observation visualized 3D dislocation arrangements and active slip planes in a deformed α-Fe specimen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.