BackgroundThe quality and viability of mastectomy flaps remain a central challenge in reconstructive surgery, particularly for immediate breast reconstruction. Insufficient perfusion in tissue flaps is a leading cause of early complications following reconstructive procedures, and clinical judgment alone is not completely reliable for the assessment of flap viability. Accurate and reliable intraoperative methods for assessment of tissue perfusion are needed to help surgeons identify tissue at risk for ischemia and necrosis, thereby allowing for maneuvers to improve tissue flap viability.MethodsThis study evaluates the use of intraoperative laser angiography using the SPY System (LifeCell Corp., Branchburg, NJ) for the assessment of perfusion in mastectomy flaps for immediate breast reconstruction. The SPY System uses the contrast agent indocyanine green, which has an excellent safety profile and pharmacokinetics that allow for repeat evaluations during the same surgical procedure. In recent work, the SPY System has demonstrated high sensitivity and specificity for detection of tissues at risk for ischemia and necrosis during reconstructive surgery. Using a retrospective, chart-review design, the authors compared consecutive cases of immediate breast reconstruction using a prosthesis, before and after implementation of the SPY System.ResultsNinety-one subjects were included in the analysis: 52 prior to SPY (Pre-SPY) and 39 after implementation of SPY (Post-SPY). Baseline characteristics were similar between the groups. Both groups had high rates of comorbidities, chemotherapy, and radiation therapy. The rate of postoperative complications was two-fold higher in the Pre-SPY group compared to the Post-SPY group (36.5% vs. 17.9%); this difference was of borderline significance (P = 0.0631). However, mean number of repeat visits to the OR per patient was significantly higher in the Pre-SPY group (1.21 ± 1.47 vs. 0.41 ± 0.71; P = 0.0023). Of the seven patients with complications in the Post-SPY group, five were identified by SPY as having poor flap perfusion; none were identified by clinical judgment alone.ConclusionsThis study suggests that the SPY System can contribute to reduced ischemia-related complications in a population of women undergoing immediate breast reconstruction following mastectomy for breast cancer.
An open, parallel, randomized, comparative, multicenter study was implemented to evaluate the cost-effectiveness, performance, tolerance, and safety of a silver-containing soft silicone foam dressing (Mepilex Ag) vs silver sulfadiazine cream (control) in the treatment of partial-thickness thermal burns. Individuals aged 5 years and older with partial-thickness thermal burns (2.5-20% BSA) were randomized into two groups and treated with the trial products for 21 days or until healed, whichever occurred first. Data were obtained and analyzed on cost (direct and indirect), healing rates, pain, comfort, ease of product use, and adverse events. A total of 101 subjects were recruited. There were no significant differences in burn area profiles within the groups. The cost of dressing-related analgesia was lower in the intervention group (P = .03) as was the cost of background analgesia (P = .07). The mean total cost of treatment was $309 vs $513 in the control (P < .001). The average cost-effectiveness per treatment regime was $381 lower in the intervention product, producing an incremental cost-effectiveness ratio of $1688 in favor of the soft silicone foam dressing. Mean healing rates were 71.7 vs 60.8% at final visit, and the number of dressing changes were 2.2 vs 12.4 in the treatment and control groups, respectively. Subjects reported significantly less pain at application (P = .02) and during wear (P = .048) of the Mepilex Ag dressing in the acute stages of wound healing. Clinicians reported the intervention dressing was significantly easier to use (P = .03) and flexible (P = .04). Both treatments were well tolerated; however, the total incidence of adverse events was higher in the control group. The silver-containing soft silicone foam dressing was as effective in the treatment of patients as the standard care (silver sulfadiazine). In addition, the group of patients treated with the soft silicone foam dressing demonstrated decreased pain and lower costs associated with treatment.
Periorbital reconstruction following skin cancer ablation represents a challenging problem. A thorough understanding of the complex periorbital anatomy is necessary to preserve lid function and protect the ocular surface. The medial canthal region represents the most difficult periorbital zone to reconstruct. This area has a complex anatomy involving both the medial canthus itself and the lacrimal apparatus. The authors present their experience with a versatile technique for reconstruction of the medial canthal periorbital region, namely, a medially based upper eyelid myocutaneous flap. In the 10 patients in whom this procedure was used, there was one partial and no complete flap losses. The authors believe that the medially based upper lid myocutaneous flap offers an excellent solution to the difficult problem of medial canthal periorbital reconstruction.
Lateral canthoplasty is a useful method of restoring lower eyelid position and thereby protecting the ocular surfaces. The success of the lateral canthoplasty procedure depends on the proper analysis of periorbital anatomy. Newer lateral canthoplasty techniques have become progressively refined in an attempt to avoid the drawbacks and pitfalls of older procedures. We present the inferior retinacular lateral canthoplasty, developed to effectively address the problems associated with lower lid laxity and/or malposition. The inferior retinacular lateral canthoplasty is a versatile reconstructive procedure that also can be used as an adjunct to aesthetic surgery. The evolution of the inferior retinacular lateral canthoplasty from over 15 years of clinical experience is discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.