The structural and optical properties of GaAs1−xBix alloys for x up to 0.108 have been investigated by high resolution X‐ray diffraction and photoluminescence (PL). At room temperature (RT), the PL intensity of the GaAs0.97Bi0.03 sample was found to be ∼300 times higher than a GaAs control sample grown at the same temperature (400 °C). PL measurements carried out at 10 K show that when excitation power, Pex was increased from 0.11 to 1140 W cm−2, the PL peak energy blue‐shifts by 80 meV while the full‐width‐at‐half‐maximum reduces from 115 to 63 meV. However, the PL peak emission energy becomes independent of the excitation power at RT. The results indicate the presence of localized energy states in the GaAs0.97Bi0.03 sample, which trap carriers at low temperatures and that the majority of the carriers become delocalized at RT. Furthermore, the temperature dependent PL also shows an S‐shape behavior, which is a signature of localization effects. A theoretical model, which was derived by solving a rate equation was employed. The model successfully reproduces the observed S‐shape behavior and the theory fits well with the experimental data. The RT band gap of GaAs1−xBix for x up to 0.108 has been plotted and compared with the literature.
This paper reports a simple technique to grow high-yield gold nanoplates directly on the surface via an effective two-dimensional growth promotion of the attached nanoseeds in the presence of a binary surfactant mixture, namely, poly(vinylpyrrolidone) (PVP) and cetyltrimethylammonium bromide (CTAB). The gold nanoplates formation strongly depended on the concentration of PVP used in the solution, while the nanoplate size depended on the CTAB concentration. In a typical process with optimum PVP and CTAB concentrations, 60% of the nanocrystal product was nanoplates. Triangular nanoplates were found to be the major shape of the nanoplates with a yield of up to ca. 50%, while hexagonal or truncated-hexagonal and rounded-nanoplates shared up to ca. 30 and 20% of the nanoplates product, respectively. The nanoplates were characterized by a very thin structure with a thickness of less than 10 nm. The edge-length size of the nanoplates was found to be up to ca. 1 µm. At optimum growth conditions, ca. 70% of the surface area was covered by nanoplates. X-ray diffraction results on the surface modified nanoplates samples indicated exceedingly high Au(111) peaks of gold nanocrystal without the presence of other peaks, such as ( 200) and ( 220), in the diffraction spectrum. The present approach may be used to produce a surface that contains unique nanostructured Au(111) crystallographic plane characteristics, which should find potential applications in catalysis, surface-enhanced Raman scattering, sensors and photonics.
This review collates around 100 papers that developed micro-electro-mechanical system (MEMS) capacitive microphones. As far as we know, this is the first comprehensive archive from academia on this versatile device from 1989 to 2019. These works are tabulated in term of intended application, fabrication method, material, dimension, and performances. This is followed by discussions on diaphragm, backplate and chamber, and performance parameters. This review is beneficial for those who are interested with the evolutions of this acoustic sensor.
The recent advancement of dielectrophoresis (DEP)-enabled microfluidic platforms is opening new opportunities for potential use in cancer disease diagnostics. DEP is advantageous because of its specificity, low cost, small sample volume requirement, and tuneable property for microfluidic platforms. These intrinsic advantages have made it especially suitable for developing microfluidic cancer diagnostic platforms. This review focuses on a comprehensive analysis of the recent developments of DEP enabled microfluidic platforms sorted according to the target cancer cell. Each study is critically analyzed, and the features of each platform, the performance, added functionality for clinical use, and the types of samples, used are discussed. We address the novelty of the techniques, strategies, and design configuration used in improving on existing technologies or previous studies. A summary of comparing the developmental extent of each study is made, and we conclude with a treatment of future trends and a brief summary.
Our goal is to design, fabricate, and characterize a pillar-based microfluidic device for size-based separation of human blood cells on an elastomeric substrate with application in the low-cost rapid prototyping of lab-chip devices. The single inlet single outlet device is using parallel U-shape arrays of pillars with cutoff size of 5.5 lm for trapping white blood cells (WBCs) in a pillar chamber with internal dead-volume of less than 1.0 ll. The microstructures are designed to limit the elastomeric deformation against fluid pressures. Numerical analysis showed that at maximum pressure loss of 15 kPa which is lower than the device conformal bonding strength, the pillar elastomeric deformation is less than 5% for flow rates of up to 1.0 ml min
Rapid prototyping (RP) of microfluidic channels in liquid photopolymers using standard lithography (SL) involves multiple deposition steps and curing by ultraviolet (UV) light for the construction of a microstructure layer. In this work, the conflicting effect of oxygen diffusion and UV curing of liquid polyurethane methacrylate (PUMA) is investigated in microfabrication and utilized to reduce the deposition steps and to obtain a monolithic product. The conventional fabrication process is altered to control for the best use of the oxygen presence in polymerization. A novel and modified lithography technique is introduced in which a single step of PUMA coating and two steps of UV exposure are used to create a microchannel. The first exposure is maskless and incorporates oxygen diffusion into PUMA for inhibition of the polymerization of a thin layer from the top surface while the UV rays penetrate the photopolymer. The second exposure is for transferring the patterns of the microfluidic channels from the contact photomask onto the uncured material. The UV curing of PUMA as the main substrate in the presence of oxygen is characterized analytically and experimentally. A few typical elastomeric microstructures are manufactured. It is demonstrated that the obtained heights of the fabricated structures in PUMA are associated with the oxygen concentration and the UV dose. The proposed technique is promising for the RP of molds and microfluidic channels in terms of shorter processing time, fewer fabrication steps and creation of microstructure layers with higher integrity.
This work investigates the surface plasmon resonance (SPR) response of 50-nm thick nano-laminated gold film using Kretschmann-based biosensing for detection of urea and creatinine in solution of various concentrations (non-enzymatic samples). Comparison was made with the presence of urease and creatininase enzymes in the urea and creatinine solutions (enzymatic samples), respectively. Angular interrogation technique was applied using optical wavelengths of 670 nm and 785 nm. The biosensor detects the presence of urea and creatinine at concentrations ranging from 50–800 mM for urea samples and 10–200 mM for creatinine samples. The purpose of studying the enzymatic sample was mainly to enhance the sensitivity of the sensor towards urea and creatinine in the samples. Upon exposure to 670 nm optical wavelength, the sensitivity of 1.4°/M was detected in non-enzymatic urea samples and 4°/M in non-enzymatic creatinine samples. On the other hand, sensor sensitivity as high as 16.2°/M in urea-urease samples and 10°/M in creatinine-creatininase samples was detected. The enhanced sensitivity possibly attributed to the increase in refractive index of analyte sensing layer due to urea-urease and creatinine-creatininase coupling activity. This work has successfully proved the design and demonstrated a proof-of-concept experiment using a low-cost and easy fabrication of Kretschmann based nano-laminated gold film SPR biosensor for detection of urea and creatinine using urease and creatininase enzymes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.