Point-of-care fluorescence immunoassay for prostate specific antigen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 54 publications
(27 citation statements)
references
References 20 publications
0
27
0
Order By: Relevance
“…However, it is important to emphasise that the detection equipment used to quantify PSA in the immuno-pillar platform was an inverted fluorescence microscope, which is not portable, cost-effective or power-free, therefore not suitable for POC applications (Ikami et al, 2010). An immunochromatographic test integrated with a Laser Fluorescence Scanner was able to detect PSA in biological samples with a lower limit of detection of 0.02 ng/ml PSA in 15 min total assay time (Oh et al, 2009). This assay was able to obtain better sensitivity than the MCFphone in less time.…”
Section: The Mcfphonementioning
confidence: 99%
“…However, it is important to emphasise that the detection equipment used to quantify PSA in the immuno-pillar platform was an inverted fluorescence microscope, which is not portable, cost-effective or power-free, therefore not suitable for POC applications (Ikami et al, 2010). An immunochromatographic test integrated with a Laser Fluorescence Scanner was able to detect PSA in biological samples with a lower limit of detection of 0.02 ng/ml PSA in 15 min total assay time (Oh et al, 2009). This assay was able to obtain better sensitivity than the MCFphone in less time.…”
Section: The Mcfphonementioning
confidence: 99%
“…Error bars were based on triplicate measurements. The LOD was calculated at 2.2 pg mL À1 according to the mean plus 3 times standard deviation (SD) [36], which is 15-fold lower than that of conventional HRP-based ELISA (34 pg mL À1 , Fig. S3).…”
Section: Analytical Performance Of the Fluorescence Elisamentioning
confidence: 99%
“…In recent years, fluorescent measurements have been extensively applied to environmental and biological analysis owing to its advantages, such as low-cost, operational simplicity, high sensitivity and real-time detection (Chen et al, , 2013Li et al 2014b). Due to these promising aspects, fluorescent immunosensors, as a kind of effective analytical technique, have been applied extensively in the quantitative detection of PSA (Oh et al, 2009). The "turn-off" switch system is commonly used for variety of fluorescence immunosensors.…”
Section: Introductionmentioning
confidence: 99%