2014
DOI: 10.1016/j.aca.2014.04.003
|View full text |Cite
|
Sign up to set email alerts
|

On-line column coupled isotachophoresis-capillary zone electrophoresis hyphenated with tandem mass spectrometry in drug analysis: Varenicline and its metabolite in human urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(23 citation statements)
references
References 22 publications
1
22
0
Order By: Relevance
“…The applicability of the method was demonstrated on the chiral separation and determination of pheniramine enantiomers in untreated human urine samples and provided LOQs at the level of 150 ng/L. Very similar sensitivities were reported with this method also for pheniramine and phenylephrine [63] and for varenicline [64].…”
Section: Online Itp-czementioning
confidence: 72%
“…The applicability of the method was demonstrated on the chiral separation and determination of pheniramine enantiomers in untreated human urine samples and provided LOQs at the level of 150 ng/L. Very similar sensitivities were reported with this method also for pheniramine and phenylephrine [63] and for varenicline [64].…”
Section: Online Itp-czementioning
confidence: 72%
“…reported the use of on‐line column coupled ITP‐CZE‐triple quadrupole (QqQ) for Vereniciline and its metabolite in human urine with LOD and LOQ in the ng–pg/mL range by injecting unpretreated (and undiluted) urine samples . The same group then compared their method with hydrodynamic open CZE hyphenated with tandem MS for pheniramine and phynylephrine in human urine . They reported that ITP‐CZE‐ESI‐QqQ has higher sensitivity in comparison to the hydrodynamic open CZE‐ESI‐QqQ that only had a LOD and LOQ in pg/mL range for diluted urine.…”
Section: Stackingmentioning
confidence: 99%
“…The use of a maximum capillary temperature and application voltage results in joule heating, which causes peak broadening and a current drop in the capillary [25]. Therefore, the effects of three different application voltages and three different capillary temperatures (15,20, and 25 °C) on the migration times were evaluated simultaneously. The observed migration times for VT and IS at different application voltages and capillary temperatures are given in Figure 3.…”
Section: Optimization Of Instrument Parametersmentioning
confidence: 99%
“…Therefore, the method developed in this study was fully validated, including robustness and ruggedness testing. Another reported method for the determination of varenicline in human urine also used CE coupled with tandem mass spectrometry (MS) [15]. However, the aim of this study is to develop a simple and rapid CE method.…”
Section: Introductionmentioning
confidence: 99%