3D printing has the potential to significantly change the field of microfluidics. The ability to fabricate a complete microfluidic device in a single step from a computer model has obvious attractions, but it is the ability to create truly three dimensional structures that will provide new microfluidic capability that is challenging, if not impossible to make with existing approaches. This critical review covers the current state of 3D printing for microfluidics, focusing on the four most frequently used printing approaches: inkjet (i3DP), stereolithography (SLA), two photon polymerisation (2PP) and extrusion printing (focusing on fused deposition modeling). It discusses current achievements and limitations, and opportunities for advancement to reach 3D printing's full potential.
One-step fabrication of transparent three-dimensional (3D) microfluidic to millifluidic devices was demonstrated using a commercial 3D printer costing $2300 with 500 mL of clear resin for $138. It employs dynamic mask projection stereolithography, allowing fast concept-to-chip time. The fully automated system allows fabrication of models of up to 43 mm × 27 mm × 180 mm (x × y × z) at printing speeds of 20 mm/h in height regardless of the design complexity. The minimal cross sectional area of 250 μm was achieved for monolithic microchannels and 200 μm for positive structures (templates for soft lithography). The colorless resin's good light transmittance (>60% transmission at wavelengths of >430 nm) allows for on-chip optical detection, while the electrically insulating material allows electrophoretic separations. To demonstrate its applicability in microfluidics, the printer was used for the fabrication of a micromixer, a gradient generator, a droplet extractor, and a device for isotachophoresis. The mixing and gradient formation units were incorporated into a device for analysis of nitrate in tap water with standard addition as a single run and multiple depth detection cells to provide an extended linear range.
A microchip solid-phase extraction method for purification of DNA from biological samples, such as blood, is demonstrated. Silica beads were packed into glass microchips and the beads immobilized with sol-gel to provide a stable and reproducible solid phase onto which DNA could be adsorbed. Optimization of the DNA loading conditions established a higher DNA recovery at pH 6.1 than 7.6. This lower pH also allowed for the flow rate to be increased, resulting in a decrease in extraction time from 25 min to less than 15 min. Using this procedure, template genomic DNA from human whole blood was purified on the microchip platform with the only sample preparation being mixing of the blood with load buffer prior to loading on the microchip device. Comparison between the microchip SPE (microchipSPE) procedure and a commercial microcentrifuge method showed comparable amounts of PCR-amplifiable DNA could be isolated from cultures of Salmonella typhimurium. The greatest potential of the microchipSPE device was illustrated by purifying DNA from spores from the vaccine strain of Bacillus anthracis, where eventual integration of SPE, PCR, and separation on a single microdevice could potentially enable complete detection of the infectious agent in less than 30 min.
Three-dimensional (3D) printing has emerged as a potential revolutionary technology for the fabrication of microfluidic devices. A direct experimental comparison of the three 3D printing technologies dominating microfluidics was conducted using a Y-junction microfluidic device, the design of which was optimized for each printer: fused deposition molding (FDM), Polyjet, and digital light processing stereolithography (DLP-SLA). Printer performance was evaluated in terms of feature size, accuracy, and suitability for mass manufacturing; laminar flow was studied to assess their suitability for microfluidics. FDM was suitable for microfabrication with minimum features of 321 ± 5 μm, and rough surfaces of 10.97 μm. Microfluidic devices >500 μm, rapid mixing (71% ± 12% after 5 mm, 100 μL/min) was observed, indicating a strength in fabricating micromixers. Polyjet fabricated channels with a minimum size of 205 ± 13 μm, and a surface roughness of 0.99 μm. Compared with FDM, mixing decreased (27% ± 10%), but Polyjet printing is more suited for microfluidic applications where flow splitting is not required, such as cell culture or droplet generators. DLP-SLA fabricated a minimum channel size of 154 ± 10 μm, and 94 ± 7 μm for positive structures such as soft lithography templates, with a roughness of 0.35 μm. These results, in addition to low mixing (8% ± 1%), showed suitability for microfabrication, and microfluidic applications requiring precise control of flow. Through further discussion of the capabilities (and limitations) of these printers, we intend to provide guidance toward the selection of the 3D printing technology most suitable for specific microfluidic applications.
Poor sensitivity is considered to be one of the major limitations of electrophoretic separation methods, particularly when compared to traditional liquid chromatographic techniques. To address this issue, various in-line preconcentration techniques have been developed over the past 15 years, ranging in power and complexity, and there are now a number of well understood approaches routinely capable of providing a 10,000- to 100,000-fold increase in sensitivity, as well as several that can be pushed above a million. Furthermore, these have been achieved with particularly troublesome and often difficult samples, such as those having high salinity from a biological or environmental origin. This review will discuss the most common methods for improving the sensitivity of CE, CEC and microchip version of these, with particular attention to those approaches developed over the last five years.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.