Kalibriernormal für Geräte der registrierenden Härteprüfung (Standard for Calibration of Instruments of Hardness Testing)

Abstract: Es wird ein Silizium-Federsystem mit integriertem Anschlag vorgestellt, das sich als Maßverkörperung von Kraft und Weg zur Kalibrierung von Geräten der registrierenden Härteprüfung eignet. Nominalwerte von Anschlagsauslenkung und dazu notwendiger Kraft sind 25 μm bzw. 425 mN. Das Normal hat eine exakt lineare Charakteristik und besitzt einen Toleranzbereich für den Belastungsort von 0.5 mm Durchmesser.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0
1

Year Published

2008
2008
2016
2016

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 0 publications
0
5
0
1
Order By: Relevance
“…NIST and NPL have developed devices with the electrostatic force acting on an electrode suspended from a vertically oriented uniaxial spring suspension [57][58][59]. PTB's system is based on a horizontally oriented disc pendulum and a variable electrostatic stiffness reduction system [60].…”
Section: Mechanical Nanometrologymentioning
confidence: 99%
“…NIST and NPL have developed devices with the electrostatic force acting on an electrode suspended from a vertically oriented uniaxial spring suspension [57][58][59]. PTB's system is based on a horizontally oriented disc pendulum and a variable electrostatic stiffness reduction system [60].…”
Section: Mechanical Nanometrologymentioning
confidence: 99%
“…The probing force is an important parameter of the micro/nano CMM probe, as has already been pointed out. We calibrate the probe's spring constant by applying a micro force calibration standard [12], which is a micro fabricated silicon cantilever as shown in figure 6. The spring constant of the cantilever has been calibrated by means of a compensation balance before usage [12].…”
Section: Force Calibrationmentioning
confidence: 99%
“…We calibrate the probe's spring constant by applying a micro force calibration standard [12], which is a micro fabricated silicon cantilever as shown in figure 6. The spring constant of the cantilever has been calibrated by means of a compensation balance before usage [12]. It should be mentioned that the force must be applied at the marked position of the cantilever, shown as the stop mark in the figure, when the standard is calibrated and when it is applied to calibrate the CMM probe.…”
Section: Force Calibrationmentioning
confidence: 99%
“…für Tastschnittgeräte mit Biegebalken-Normalen aus Silizium möglich [7]. Für die Kalibrierung von Indentern für die instrumentierte Eindringprüfung sind kalibrierte mikromechanische Silizium-Federn verfügbar, die allerdings neben einer hohen Linearität einen Kalibrierpunkt in der Kraft-Auslenkungs-Charakteristik aufweisen [8][9][10]. Man erreicht dies durch eine Verbindung zweier Federkörper in einem Chip-Stapel [8,9] oder auch monolithisch integriert an der Oberfläche eines einzigen Chips [10].…”
Section: Introductionunclassified