The LHCb experiment is dedicated to precision measurements of CP violation and rare decays of B hadrons at the Large Hadron Collider (LHC) at CERN (Geneva). The initial configuration and expected performance of the detector and associated systems, as established by test beam measurements and simulation studies, is described.
Accurate and traceable calibration of lateral standards (1D and 2D gratings) is a basic metrological task for nano- and microtechnology. Both the mean pitch and the uniformity of the gratings should be measured quantitatively. Although optical diffractometers are effective for measuring the mean pitch, they are not able to measure the uniformity of gratings. In this study, the calibration of gratings is performed using a metrological large range scanning probe microscope with optimized measurement strategies. Two different kinds of data evaluation methods, a gravity centre method and a Fourier transform method, have been developed and investigated. Cosine error, a significant error source of the measurement, is analysed and corrected. Calibrations on several 1D gratings have been carried out. The calibrated mean pitch values have an excellent agreement with those measured by optical diffractometry. Nevertheless, irregularities of the gratings were only deduced from the SPM results. Finally, the usage of the 1D/2D gratings for the calibration of a typical SPM is illustrated.
We describe a metrological large range scanning probe microscope (LR-SPM) with an Abbe error free design and direct interferometric position measurement capability, aimed at versatile traceable topographic measurements that require nanometer accuracy. A dual-stage positioning system was designed to achieve both a large measurement range and a high measurement speed. This dual-stage system consists of a commercially available stage, referred to as nanomeasuring machine (NMM), with a motion range of 25 mm×25 mm×5 mm along x, y, and z axes, and a compact z-axis piezoelectric positioning stage (compact z stage) with an extension range of 2 μm. The metrological LR-SPM described here senses the surface using a stationary fixed scanning force microscope (SFM) head working in contact mode. During operation, lateral scanning of the sample is performed solely by the NMM. Whereas the z motion, controlled by the SFM signal, is carried out by a combination of the NMM and the compact z stage. In this case the compact z stage, with its high mechanical resonance frequency (greater than 20 kHz), is responsible for the rapid motion while the NMM simultaneously makes slower movements over a larger motion range. To reduce the Abbe offset to a minimum the SFM tip is located at the intersection of three interferometer measurement beams orientated in x, y, and z directions. To improve real time performance two high-end digital signal processing (DSP) systems are used for NMM positioning and SFM servocontrol. Comprehensive DSP firmware and Windows XP-based software are implemented, providing a flexible and user-friendly interface. The instrument is able to perform large area imaging or profile scanning directly without stitching small scanned images. Several measurements on different samples such as flatness standards, nanostep height standards, roughness standards as well as sharp nanoedge samples and 1D gratings demonstrate the outstanding metrological capabilities of the instrument.
Two-dimensional (2D) gratings are widely used for calibrating the xy-plane of nearly all kinds of microscopes. The mean pitch, orthogonality and local pitch uniformity of the 2D gratings have to be calibrated prior to usage. In this paper, a method of accurate calibration of 2D gratings using a metrological large-range scanning force microscope is presented. A new measurement strategy is proposed, where the 2D gratings are measured in two narrow rectangular areas for determining all desired measurands and a small square area for viewing the grids in detail. The proposed strategy greatly shortens the measurement time, reduces the drift and eases the data processing procedure. Different data evaluation methods are introduced. Several 2D gratings with mean pitches from 100 nm to 10 µm have been calibrated, the results agree well with the values determined by an optical diffractometer. The expanded uncertainty (k = 2) of the mean pitch was approximately 15 pm for a 2D grating with a nominal mean pitch of 1000 nm, i.e. a relative uncertainty of 1.5 × 10−5.
Traceable and accurate reference dimensional metrology of nano-structures by scanning transmission electron microscopy (STEM) is introduced in the paper. Two methods, one based on the crystal lattice constant and the other based on the pitch of a feature pair, were applied to calibrate the TEM magnification. The threshold value, which was defined as the half-intensity of boundary materials, is suggested to extract the boundary position of features from the TEM image. Experimental investigations have demonstrated the high potential of the proposed methods. For instance, the standard deviation from ten repeated measurements of a line structure with a nominal 100 nm critical dimension (CD) reaches 1σ = 0.023 nm, about 0.02%. By intentionally introduced defocus and larger sample alignment errors, the investigation shows that these influences may reach 0.20 and 1.3 nm, respectively, indicating the importance of high-quality TEM measurements. Finally, a strategy for disseminating the destructive TEM results is introduced. Using this strategy, the CD of a reference material has been accurately determined. Its agreement over five independent TEM measurements is below 1.2 nm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.