Gold interdigitated triple-microelectrodes for label-free prognosticative aptasensing of prostate cancer biomarker in serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
34
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(35 citation statements)
references
References 28 publications
0
34
0
1
Order By: Relevance
“…To observe the diffusivity of the electrolyte onto the electrode surface, wettability of the electrode matrix was measured by a 5 µL water drop contact angle observation. The LAG exhibited higher contact angle around (150.2 ± 3)°, PAAMI‐treated LAG exhibited (44.1 ± 3)°, and PtNPs/PAAMI/LAG exhibited (41.9 ± 3) °, as shown in Figure 3e–g, respectively; consequently, these contact angles indicate that the PAAMI‐treated LAG and PtNPs/PAAMI/LAG are more hydrophilic than the bare LAG electrode 15,20…”
Section: Resultsmentioning
confidence: 85%
See 1 more Smart Citation
“…To observe the diffusivity of the electrolyte onto the electrode surface, wettability of the electrode matrix was measured by a 5 µL water drop contact angle observation. The LAG exhibited higher contact angle around (150.2 ± 3)°, PAAMI‐treated LAG exhibited (44.1 ± 3)°, and PtNPs/PAAMI/LAG exhibited (41.9 ± 3) °, as shown in Figure 3e–g, respectively; consequently, these contact angles indicate that the PAAMI‐treated LAG and PtNPs/PAAMI/LAG are more hydrophilic than the bare LAG electrode 15,20…”
Section: Resultsmentioning
confidence: 85%
“…Therefore, these functional groups are crucially desired due to their stable covalent immobilization. The reduced form of graphene called reduced graphene oxide (rGO) is widely incorporated on sensing platforms for developing highly sensitive and selective biosensors 10,17–21. However, the multistage synthesis and use of toxic reductants are required to synthesize or functionalize rGO.…”
Section: Introductionmentioning
confidence: 99%
“…A micromachined Teflon tape was adhered on the board around the sensing area, in order to separate one electrochemical cell on the PCB from another, and locally confine the reagents. The impedance spectra were recorded using gold as counter and pseudo-reference electrodes at an open circuit potential (OCP) in the frequency range of 100 kHz to 0.5 Hz, with a 60 mV amplitude in 50 µL of 100 mM PBS (pH 7.4) containing 2 mM of the [Fe(CN) 6 ] 3−/4− redox couple [30]. All electrochemical data were obtained at room temperature (25 °C).…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Regarding chronoamperometric biosensors, antibodies [8][9][10], aptamers [11], peptides [12] and enzymes [13] have been used as recognition molecules, and they are based on dual potentiometry. Regarding impedimetric biosensors using IDE, antibodies [24][25][26][27][28] and aptamers [29] have been used as the primary molecular recognition elements, as affinity-based detection requires strong binding and selective biomolecules for impedance measurement. With impedimetric biosensors, measurement is based on the access of a redox probe to the electrode surface, and changes occur when an insulating layer is produced with the recognition element/antigen complex, which reduces the transfer of electrons.…”
Section: Measurement Of Fructosyl Lysine and Ga With An Ide Enzyme Sementioning
confidence: 99%