2008
DOI: 10.1248/bpb.31.2309
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Zwitterionic Polymers on Wound Healing

Abstract: The effect of a thin film of a zwitterionic random copolymer composed of carboxybetaine [1-carboxy-N,Ndimethyl-N-(2 -methacryloyloxyethyl)methanaminium inner salt] (CMB) and n-butyl methacrylate (BMA), poly(CMB-r-BMA) (CMB, 30 mol%), on the healing of a full-thickness excisional and incisional wound in hairless rats was examined. The poly(CMB-r-BMA) film significantly enhanced wound closure and complete healing of a full-thickness excisional wound compared with the effect of the poly(n-butyl methacrylate) (PBM… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
28
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 40 publications
(31 citation statements)
references
References 28 publications
3
28
0
Order By: Relevance
“…The non-specific adsorption of bovine serum albumin (BSA), human immunoglobulin G (IgG) and bovine plasma fibrinogen (BPF) to the glass substrate was evaluated using bicinchoninic acid (BCA) method (see Supporting information) [50].…”
Section: Adsorption Of Proteinmentioning
confidence: 99%
“…The non-specific adsorption of bovine serum albumin (BSA), human immunoglobulin G (IgG) and bovine plasma fibrinogen (BPF) to the glass substrate was evaluated using bicinchoninic acid (BCA) method (see Supporting information) [50].…”
Section: Adsorption Of Proteinmentioning
confidence: 99%
“…Anti-biofouling materials, which resist protein adsorption or cell adhesion, have widespread demand for various biomedical applications such as contact lens 1 , endoscope 2 , artificial organs implants 3 , plasters for wound healing 4 , and biosensors. 5 Various hydrophilic anti-biofouling materials, such as polyethylene glycol (PEG) 6,7 , zwitterionic polymers of phosphobetaine (PB) 8 , sulfobetaine (SB) 9 , and carboxybetaine (CB) 10 have been presented.…”
Section: Introductionmentioning
confidence: 99%
“…Subsequently, the films were sonicated for 120 min in PBS to detach any protein adsorbed onto the native PDMS and b-PDMS surfaces. Then, the solution was collected, and the amount of protein was determined by the Micro BCA (bicinchoninic acid) Protocol (Micro BCA Protein Assay Kit, Sangon Biotech Co., Ltd., Shanghai, China) (26)(27). Afterwards, the amount of adsorbed protein was calculated according to the standard protein curve, which was measured with different concentrations of a protein standard.…”
Section: Protein Adsorptionmentioning
confidence: 99%