Combination of single particle ICP-QMS and isotope dilution analysis for the determination of size, particle number and number size distribution of silver nanoparticles

Abstract: Successful compensation of matrix effects by a combination of single particle ICP-MS and isotope dilution analysis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 37 publications
(55 reference statements)
0
16
0
Order By: Relevance
“…However, substantial matrix effect on NPs can be problematic if NP suspensions for spICP-MS measurement are dispersed in biological or environmental media containing a high content of matrix (e.g., phosphate-buffered saline, sea water, etc. ), which may require sensitivity correction using isotopic dilution analysis [60] or matrix matched ionic standards [27]. For samples that need additional dilution in water or the proposed diluents from this study, the matrix effect on NPs is expected to be low.…”
Section: Resultsmentioning
confidence: 99%
“…However, substantial matrix effect on NPs can be problematic if NP suspensions for spICP-MS measurement are dispersed in biological or environmental media containing a high content of matrix (e.g., phosphate-buffered saline, sea water, etc. ), which may require sensitivity correction using isotopic dilution analysis [60] or matrix matched ionic standards [27]. For samples that need additional dilution in water or the proposed diluents from this study, the matrix effect on NPs is expected to be low.…”
Section: Resultsmentioning
confidence: 99%
“…Cl naturally can be found as 35 Cl (~76%) and 37 Cl (~24%). Since 75 ArCl and 77 ArCl should be formed proportionally in the plasma, there should be an about three times decreased signal for 77 ArCl if compared to the signal observed at mass 75. As can be seen in Figure 46, this is not the case.…”
Section: Potential Mass Interferences Of Detected Isotopesmentioning
confidence: 92%
“…Methods to measure nanoparticles using the popular sp-ICP-MS mode were already established in Dr. Jakubowskis' group (BAM division 1.1) and served as a starting point. [77][78][79] First tests were carried out using a quadrupole ICP-MS (iCAP Q, Thermo Fisher Scientific)…”
Section: Establishing Sc-icp-ms Methods and Testing Of Cell Tagging Pmentioning
confidence: 99%
See 1 more Smart Citation
“…The compensation of NaCl matrix effects via this approach was investigated and confirmed by Sötebier et al. 89 But, with regard to independent single particle events it is important to collect a sufficient number of data to allow for an appropriate averaging and thus reduce errors in the isotope ratios.…”
Section: Materials Namementioning
confidence: 93%