2017
DOI: 10.1007/s00216-017-0530-4
|View full text |Cite
|
Sign up to set email alerts
|

Overcoming challenges in single particle inductively coupled plasma mass spectrometry measurement of silver nanoparticles

Abstract: Single particle ICP-MS has evolved rapidly as a quantitative method for determining nanoparticle size and number concentration at environmentally relevant exposure levels. Central to the application of spICP-MS is a commonly used, but not rigorously validated, calibration approach based on the measured transport efficiency and the response of ionic standards. In this work, we present a comprehensive and systematic study of the accuracy, precision and robustness of spICP-MS using the rigorously characterized re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
26
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(28 citation statements)
references
References 56 publications
(105 reference statements)
1
26
0
1
Order By: Relevance
“…Furthermore, it is challenging to obtain consistent/reproducible measurements of size, size distribution, and the number of particle concentration using spICP-MS [ 49 ]. Nonetheless, spICP-MS is a promising technique that can rapidly provide comprehensive physico-chemical properties data of ENMs (i.e., particle concentration, size distribution, apparent core density, and state of aggregation) [ 47 , 50 , 51 ].…”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, it is challenging to obtain consistent/reproducible measurements of size, size distribution, and the number of particle concentration using spICP-MS [ 49 ]. Nonetheless, spICP-MS is a promising technique that can rapidly provide comprehensive physico-chemical properties data of ENMs (i.e., particle concentration, size distribution, apparent core density, and state of aggregation) [ 47 , 50 , 51 ].…”
Section: Resultsmentioning
confidence: 99%
“…† The median sizes value obtained from SEM are in agreement with the manufacturer data but the standard deviation for our measurement is high due to the relatively small sample size: only ∼100 particles per SEM size distribution. Furthermore, silver NPs-which are sensitive particle to light 21 -show a wider distribution tail toward smaller NP diameter; this is evidence for degradation of the NPs (see Fig. S5e †).…”
Section: Multiplexed-np Analysis By Sp-icp-tofmsmentioning
confidence: 88%
“…sensitivity) are determined. [19][20][21] Depending on the NP-containing matrix, both transport efficiency and/or elemental sensitivity may change and cause inaccurate calibration of PNC or element mass. 22 In the context of environmental analysis, temporally and spatially variable matrix characteristics, such as dissolved organic content, total salt content, or pH, could impact the accuracy of sp-ICP-MS analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Laborda et al present a very detailed explanation of the principles and key considerations for successful sp-ICP-MS (Laborda et al 2013(Laborda et al , 2016. Earlier studies discussed a number of challenges even for the measurement of very well-defined NPs in simple aqueous matrices (Liu et al 2017;Mitrano et al 2012Mitrano et al , 2014Reed et al 2012), but more recent work indicates that this technique is becoming more common for aqueous samples (Montano et al 2016). As the technique has matured, it has been applied to a wider range of elemental compositions (Frechette-Viens et al 2017;Lee et al 2014;Praetorius et al 2017) and samples (Azodi et al 2016;Hadioui et al 2015;Schwertfeger et al 2016).…”
Section: Introductionmentioning
confidence: 99%