2009
DOI: 10.1590/s0100-69162009000100007
|View full text |Cite
|
Sign up to set email alerts
|

Entupimento de gotejadores em função da aplicação de superfosfato simples e ácido nítrico

Abstract: RESUMO:O superfosfato simples (SS) é uma alternativa aos adubos fosfatados que são utilizados via fertirrigação, como o ácido fosfórico, que provoca acidificação do bulbo úmido no solo, e o monofosfato de amônio purificado, que apresenta maior preço. No entanto, não se conhece o efeito de tal adubo no funcionamento de emissores, principalmente nos gotejadores, nem se é possível controlar o entupimento por SS por meio de aplicações de ácido. Assim, desenvolveu-se este trabalho com o objetivo de avaliar a possib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0
5

Year Published

2011
2011
2017
2017

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 4 publications
1
7
0
5
Order By: Relevance
“…According to the criterion of sensitivity of the emitters to the reduction in flow rate proposed by Barros et al (2009), the dripper G2 is characterized as sensitive from 500 h of operation on; G3, from 600 h of operation on, i.e., until 400 h, it did not show sensitivity to the reduction in flow rate. According to the same authors, only G3 showed Qr variation higher than 10% and CVQ above 5.50%, being characterized as sensitive to the reduction in flow rate.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…According to the criterion of sensitivity of the emitters to the reduction in flow rate proposed by Barros et al (2009), the dripper G2 is characterized as sensitive from 500 h of operation on; G3, from 600 h of operation on, i.e., until 400 h, it did not show sensitivity to the reduction in flow rate. According to the same authors, only G3 showed Qr variation higher than 10% and CVQ above 5.50%, being characterized as sensitive to the reduction in flow rate.…”
Section: Resultsmentioning
confidence: 99%
“…Since there is not a norm to characterize the susceptibility of the dripper to clogging, the criterion suggested by Barros et al (2009) was adopted as the main analysis of the sensitivity of the emitters to clogging by the TSE, which is separated into three categories according to the sensitivity to clogging.…”
Section: Methodsmentioning
confidence: 99%
“…In the G6 model, before applying the acid, the values of Qr remained low, 6.17% (Qr <10%, Barros et al, 2009) and CV values were good, 4.89% (CV <10%, HILLEL, 1982). In models G2, G3 and G5, the graphs showed that the Qr values remained with a low range, and CV values are considered good values according to HILLEL (1982).…”
Section: Susceptibility To Blockagementioning
confidence: 97%
“…Agríc., Jaboticabal, v.31, n.5, p.887-894, set./out. 2011 From the data, a classification of models was made according to the proposal of BARROS et al (2009) to compare the sensitivity of the emitters to the application of Ca(OH) 2 .…”
Section: Effect Of Acidmentioning
confidence: 99%
See 1 more Smart Citation