Background and ObjectiveThe identification and quantification of potential drug–drug interactions is important for avoiding or minimizing the interaction-induced adverse events associated with specific drug combinations. Clinical studies in healthy subjects were performed to evaluate potential pharmacokinetic interactions between vortioxetine (Lu AA21004) and co-administered agents, including fluconazole (cytochrome P450 [CYP] 2C9, CYP2C19 and CYP3A inhibitor), ketoconazole (CYP3A and P-glycoprotein inhibitor), rifampicin (CYP inducer), bupropion (CYP2D6 inhibitor and CYP2B6 substrate), ethinyl estradiol/levonorgestrel (CYP3A substrates) and omeprazole (CYP2C19 substrate and inhibitor).MethodsThe ratio of central values of the test treatment to the reference treatment for relevant parameters (e.g., area under the plasma concentration–time curve [AUC] and maximum plasma concentration [Cmax]) was used to assess pharmacokinetic interactions.ResultsCo-administration of vortioxetine had no effect on the AUC or Cmax of ethinyl estradiol/levonorgestrel or 5′-hydroxyomeprazole, or the AUC of bupropion; the 90 % confidence intervals for these ratios of central values were within 80–125 %. Steady-state AUC and Cmax of vortioxetine increased when co-administered with bupropion (128 and 114 %, respectively), fluconazole (46 and 15 %, respectively) and ketoconazole (30 and 26 %, respectively), and decreased by 72 and 51 %, respectively, when vortioxetine was co-administered with rifampicin. Concomitant therapy was generally well tolerated; most adverse events were mild or moderate in intensity.ConclusionDosage adjustment may be required when vortioxetine is co-administered with bupropion or rifampicin.Electronic supplementary materialThe online version of this article (doi:10.1007/s40261-013-0117-6) contains supplementary material, which is available to authorized users.
Overall, treatment with pioglitazone/metformin FDC demonstrated greater efficacy than its individual components. The FDC therapy was well tolerated, with reduced or similar adverse event rates compared with each individual monotherapy.
Background. Over the past decades, lots of advance have occurred in the prevention, diagnosis, and treatment of head and neck cancer (HNC). However, the contemporaneous incidence and survival trends, on the basis of population-based registry, have not been reported. Methods. The HNC cancer cases were accessed from the Surveillance, Epidemiology, and End Results (SEER) database. The incidence trend was analyzed by joinpoint analysis, with the survival trend being analyzed by period analysis of relative survival rate (RSR) and Kaplan-Meier analyses. Cox regression analysis was performed to identify the prognostic factors for overall survival. Results. The general incidence trend of HNC increases slightly, with an average annual percentage change of 0.6%, along with five fluctuating segments. The improvement of net survival over the past decades was showed by increasing 60-month RSR, from 54.1% to 56.0% to 60.9% to 66.8%, which was further confirmed by Kaplan-Meier analyses. Moreover, disparities in incidence and survival patterns can be observed in different subgroups. Conclusion. A fluctuating incidence pattern and an ever-improving survival were observed in HNC over time.
Objective: Compare detrusor muscle of normal and patients with infravesical obstruction, quantifying the collagen and elastic system fibers. Materials and Methods: We studied samples taken from bladders of 10 patients whose ages ranged from 45 to 75 years (mean = 60 years), who underwent transvesical prostatectomy for treatment of BPH. Control material was composed of 10 vesical specimens, removed during autopsies performed in cadavers of accident victims, with ages between 18 and 35 years (mean = 26 years). Results: The results of collagen and elastic fibers quantification (volumetric density) demonstrated the following results in percentage (mean +/-standard deviation): collagen in BPH patients = 4.89 +/-2.64 and 2.32 +/-1.25 in controls (p < 0.0001), elastin in BPH patients = 10.63% +/-2.00 and 8.94% +/-1.19 in controls (p < 0.0001). Conclusion: We found that the components of connective tissue, collagen and elastic system fibers are increased in the detrusor muscle of patients with infravesical obstruction, when compared to controls.
The CYP3A4 enzyme is known for its atypical inhibition kinetics; ligand inhibition can differ depending upon the probe drug used. A high throughput-LCMS/MS CYP3A4 inhibition assay with four substrate drugs was developed to minimize the potential oversight of CYP3A4 inhibition. The assay uses a 96-well format, human liver microsomes, and four CYP3A4 substrate drugs, midazolam, testosterone, nifedipine and terfenadine. After incubation of the individual substrate with human liver microsomes, the reaction is stopped by solid phase extraction and the four probe metabolites produced are pooled and measured by LCMS/MS with multiple-ion-monitoring mode. Using this assay, the IC(50) values of fourteen compounds recognized as substrates/inhibitors of CYP3A4, were measured for the CYP3A4 catalyzed-metabolism of probe drugs. IC(50) values were also obtained for the common set of compounds by the microtiter plate fluorescent assays with cDNA-expressed CYP3A4. Comparison of the results from the two methods suggests that decision making should be cautiously executed to predict drug interaction potential caused by inhibition of CYP3A4 considering the gap between the two assays and various other factors.
Bioavailability of pioglitazone and metformin, in 2 dose strengths, given either as a fixed-dose combination tablet or as coadministration of commercial tablets (coad), was studied in young healthy subjects in 2 separate studies. In study I (n = 63), single oral doses of 15-mg pioglitazone/500-mg metformin fixed-dose combination tablets or equivalent doses of commercial tablets were administered, in a fasting state, in an open-label, randomized, crossover study with a 7-day washout period between treatments. Study II (n = 61) was similar in design to study I, except the 15/850-mg fixed-dose combination tablet and coad treatments were evaluated. Least squares mean (fixed-dose combination/coad) ratios and 90% confidence intervals of the ratios for the 15/500-mg dose strength for the maximum observed serum concentration (Cmax) and area under the serum concentration-time curve from time 0 to infinity (AUC(infinity)) were 0.95 (0.86-1.05) and 1.02 (0.98-1.08), respectively, for pioglitazone and 0.99 (0.95-1.03) and 1.03 (0.98-1.08), respectively, for metformin. Bioequivalency for pioglitazone and metformin between fixed-dose combination tablets and coad treatments was met for both strengths of fixed-dose combination tablets. In a post hoc meta-analysis of combined data from the 2 studies (n = 124), there was considerable overlapping in AUC(infinity) values between gender and race (Caucasians, Blacks, and Hispanics), making neither gender- nor racial-based dosing of pioglitazone or metformin necessary.
Background
The accurate and precise quantification of HbA1c is essential for the diagnosis and routine monitoring of patients with diabetes. We report an evaluation of the Trinity Biotech Premier Hb9210 analyser (Bray, Ireland/Kansas City, US), a boronate affinity chromatography-based high performance liquid chromatography (HPLC) system for the measurement of glycated haemoglobin.
Methods
We evaluated the analytical performance of the Hb9210 as part of a multicentre evaluation. The effect of haemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and National Glycohemoglobin Standardization Program (NGSP) reference systems, was assessed. Most of the centres participating also act as reference laboratories for both the IFCC standardisation network for HbA1c and the NGSP.
Results
The combined data from all centres showed total CVs of 2.71%, 2.32% and 2.14% at low medium and high values respectively for mmol/mol (SI units) and 1.62%, 1.59% and 1.68% for % (NGSP units), which are well below the recommended upper limits of 3% CV for SI (IFCC) units and 2% CV for % (NGSP). The analyser showed a good correlation to HbA1c methods currently used in clinical practice and the IFCC reference method procedure. Haemoglobin variants AC, AS, AE and AD do not affect the measurement of HbA1c. Overall the Hb9210 performs well across the whole analytical range.
Conclusions
The Hb9210 performs well and is suitable for clinical application in the analysis of HbA1c.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.