An accurate selection of strain energy function (SEF) plays a very important role for predicting the actual behavior of rubber material in the finite element analysis (FEA). The common method for selecting the SEF is by using the curve fitting procedure. However, the behavior of some typical rubbers, such as low grade rubbers (average hardness value of 47.2), cannot be predicted well by only using the curve fitting procedure. To accurately predict the actual behavior of such specifically nearly incompressible material, a series of FEA were carried out to simulate the actual behavior of four physical testing materials, namely the uniaxial, the planar shear, the equibiaxial, and the volumetric tests. This FEA is intended to examine the most suitable constitutive model in representing the rubber characteristics and behavior. From the comparisons, it can be concluded that the Ogden model provides a reasonably accurate prediction compared to the remaining investigated constitutive material models. Finally, the appropriate SEF, i.e. the Ogden model, was adopted for modeling a low-cost rubber base isolator (LCRBI) in the finite element analysis (FEA). The simple uniaxial compression test of the LCRBI is required for validating that the selected SEF works for predicting the actual behavior of LCRBI.
Introdution: This paper proposed a Small Buckling-Restrained Brace (SBRB) for the ductile truss moment frames and is called here as the Double Braced Truss Moment Frames (DB-TMF). The braces are located at the edge of the truss girder and are only placed around the building perimeter. The braces work in pair as a weak element (structural fuses) and is expected to effectively absorb the seismic energy. The proposed DB-TMF system is an extended development of the Knee Braced Truss Moment Frames (KB-TMF). The DB-TMF system is expected to carry the whole seismic loads, while the rest of the frame is designed to carry only the gravity loads. Methods: To study the performance of the proposed DB-TMF system, non-linear finite element analysis was carried out using the DRAIN-2DX package. From the analysis with various time history records, it was found that the drift ratio of the DB-TMF system is lower than the allowed story drift. The roof-top displacement shows an asymptotic behavior. The shape of the hysteresis curve tends to have a pinching shape. However, the cumulative ductility of the proposed system satisfies the requirements as a hysteretic structure. In the event of an earthquake, only the SBRB and the chords adjacent to the column element are damaged while the rest of the structural elements remain elastic which is expected. Results and Conclusion: Based on the performance evaluation of the DB-TMF system, the DB-TMF system is suitable for moderate seismic region and has smaller dimension steel sections compared to the KB-TMF system.
The basic concept of the application of base isolation is by extending the natural period of the structure in order to provide lower seismic acceleration. The paper focuses on the investigation of the application of lead-rubber bearings (LRBs) instead of pot bearings in a new Kutai Kartanegara steel arch bridge located in East Kalimantan province. Even though the bridge is known located in Seismic Zone 1 (the zone with the least seismic risk as per SNI 2833-2013), the study was extended for other higher risk seismic zones, namely Seismic Zones 2, 3, and 4. With the aid of Midas software, the analyses of the bridge structures were carried out and it can be concluded that the higher the seismic risk, the more effective the use of LRBs in dissipating the earthquake energy before transmitting to the bridge superstructure. The reductions of seismic base shears obtained from the analyses were between 23.10 and 44.67 percent and 17.07 and 31.47 percent in the longitudinal and transverse directions, respectively. However, the application of LRBs has a consequence of increasing the horizontal displacements of the bridge, which can be solved by introducing either larger expansion joints or passive dampers. In order to validate the seismic responses, the bridge was analyzed using Time History Analysis (THA) by imposing seven earthquake ground motions, which were scaled to a spectral design of Padang as a requirement by the Indonesian code.
ABSTRAKKereta api komuter Sulam merupakan salah satu transportasi umum massal alternatif yang dapat melayani pergerakan pekerja komuter dari Kabupaten Lamongan ke Kota Surabaya. PT. KAI DAOP 8 selaku pengelola harus mampu memberikan pelayanan yang maksimal bagi pengguna kereta api komuter Sulam, sehingga jumlah penumpang dapat meningkat seiring dengan peningkatan pelayanan. Penelitian ini bertujuan untuk mengetahui karakteristik penumpang kereta api komuter Sulam, sehingga dapat dijadikan dasar identifikasi awal. Metode survei wawancara dilakukan kepada 300 reseponden yang dilakukan pada hari kerja pada jam sibuk pagi dan sore hari. Hasil penelitian berdasarkan survei wawancara didapat 55% penumpang adalah perempuan, dengan maksud perjalanan bekerja sebesar 53% dan 40% berusia 21 30 tahun. Sebanyak 51% responden menggunakan kereta api komuter lebih dari 3 kali dalam satu minggu, responden menggunakan kereta api komuter untuk berangkat dan pulang kerja setiap harinya. Besarnya penghasilan 32% responden adalah Rp2.000.000,00 Rp3.000.000,00. Sebanyak 40% penumpang beralasan menggunakan kereta api komuter Sulam karena biaya yang lebih murah dibanding sarana transportasi lain dengan tujuan yang sama ke Kota Surabaya.Kata kunci: kereta api komuter Sulam, karakteristik penumpang, layanan. ABSTRACTThe Sulam commuter train is one of the alternative mass public transportation that can serve the movement of commuter workers from Lamongan Regency to Surabaya City. PT. KAI DAOP 8 as the manager must be able to provide maximum service for users of the Sulam commuter train, so that the number of passengers can increase along with the increase in service. This study aims to determine the characteristics of passenger commuter train, so that it can be used as the basis for initial identification. The interview survey method was conducted for 300 prescribers who were carried out on weekdays in the morning and evening rush hours. The results of the study based on interview surveys found 55% of passengers were women, with the intention of working trips of 53% and 40% aged 21 30 years. Amounting to 51% of respondents use commuter trains more than 3 times a week, respondents use commuter trains to leave and go home from work every day. The amount of income 32% of respondents is Rp2,000,000,00 Rp3,000,000,00. Amounting to 40% of passengers have reason to use the Sulam commuter train because the cost is cheaper than other transportation facilities with the same destination to Surabaya City.Keywords: sulam commuter train, passenger characteristic, service.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.