Abstract:In this paper, we demonstrate a new single-cell optoporation and transfection technique using a femtosecond Gaussian laser beam and optical tweezers. Tightly focused near-infrared (NIR) femtosecond laser pulse was employed to transiently perforate the cellular membrane at a single point in MCF-7 cancer cells. A distinct technique was developed by trapping the microparticle using optical tweezers to focus the femtosecond laser precisely on the cell membrane to puncture it. Subsequently, an external gene was introduced in the cell by trapping and inserting the same plasmidcoated microparticle into the optoporated cell using optical tweezers. Various experimental parameters such as femtosecond laser exposure power, exposure time, puncture hole size, exact focusing of the femtosecond laser on the cell membrane, and cell healing time were closely analyzed to create the optimal conditions for cell viability. Following the insertion of plasmid-coated microparticles in the cell, the targeted cells exhibited green fluorescent protein (GFP) under the fluorescent microscope, hence confirming successful transfection into the cell. This new optoporation and transfection technique maximizes the level of selectivity and control over the targeted cell, and this may be a breakthrough method through which to induce controllable genetic changes in the cell.
Vital sign monitoring in neonates requires adhesive electrodes, which often damage fragile newborn skin. Because impulse radio ultrawideband (IR-UWB) radar has been reported to recognize chest movement without contact in adult humans, IR-UWB may be used to measure respiratory rates (RRs) in a non-contact fashion. We investigated the feasibility of radar sensors for respiration monitoring in neonates without any respiratory support to compare the accuracy and reliability of radar measurements with those of conventional impedance pneumography measurements. In the neonatal intensive care unit, RRs were measured using radar (RR Rd ) and impedance pneumography (RR IP ) simultaneously. The neonatal voluntary movements were measured using the radar sensor and categorized into three levels (low [M 0 ], intermediate [M 1 ] and high [M 2 ]). RR Rd highly agreed with RR IP ( r = 0.90; intraclass correlation coefficient [ICC] = 0.846 [0.835–0.856]). For the M 0 movement, there was good agreement between RR Rd and RR IP (ICC = 0.893; mean bias −0.15 [limits of agreement (LOA) −9.6 to 10.0]). However, the agreement was slightly lower for the M 1 (ICC = 0.833; mean bias = 0.95 [LOA −11.4 to 13.3]) and M 2 (ICC = 0.749; mean bias = 3.04 [LOA –9.30 to 15.4]) movements than for the M 0 movement. In conclusion, IR-UWB radar can provide accurate and reliable estimates of RR in neonates in a non-contact fashion. The performance of radar measurements could be affected by neonate movement.
Objectives: Data regarding acute severe hypertension, a life-threatening condition encountered in the emergency department, are limited. We aimed to identify the characteristics, practice patterns, and outcomes of patients with acute severe hypertension in the emergency department.Methods: This cross-sectional study at a tertiary referral centre included patients aged at least 18 years who were admitted to the emergency department between January 2016 and December 2019 for acute severe hypertension, which was defined as SBP at least 180 mmHg and/or DBP at least 100 mmHg.Results: Of 172 105 patients who visited the emergency department, 10 219 (5.9%) had acute severe hypertension. Of them, 2506 (24.5%) patients had acute hypertensionmediated organ damage (HMOD), and these patients had more cardiovascular risk factors than did patients without HMOD. Additionally, 4137 (40.5%) patients were admitted, and nine (0.1%) died in the emergency department. The overall 3-month, 1-year, and 3-year mortality rates were 4.8, 8.8, and 13.9%, respectively. In patients with HMOD, the 1-year mortality rate was 26.9%, and patients lost to follow-up had a significantly higher 1year mortality rate than those who were followed up (21.3 vs. 10.5%, respectively, P < 0.001). Conclusion:The mortality rate in patients with acute severe hypertension in the emergency department is high, especially in patients with HMOD. Evaluation of HMOD, investigating the underlying causes, and adequate followup are mandatory to improve the outcomes in these patients. This study emphasizes the need for diseasespecific guidelines that include detailed acute treatment strategies and follow-up management for acute severe hypertension.
Non-invasive delivery of artificial implants, stents or devices in patients is vital for rapid and successful recovery. Unfortunately, because the delivery passage is often narrower than the size of the delivered object, a compromise between the shape that is effective at the targeted location and a thin form that allows smooth unobstructed travel to the destination is needed. We address this problem through two key technologies: 3D printing and shape memory polymers (SMPs). 3D printing can produce patient-customizable objects, and SMPs can change their initially formed shape to the final desired shape through external stimulation. Using these two technologies, we examine the design and fabrication of bifurcated stents. This study presents a mock-up where blood vessels are fabricated using moulded silicon, which supports the effectiveness of the proposed method. The experimental results reveal that a bifurcated stent with a kirigami structure can smoothly travel inside a vessel without being obstructed by branched parts. We believe that this work can improve the success rate of stent insertion operations in medicine.
We discovered that impulse-radio ultra-wideband (IR-UWB) radar could recognize cardiac motions in a non-contact fashion. Therefore, we measured the heart rate (HR) and rhythms using an IR-UWB radar sensor and evaluated the validity and reliability of the measurements in comparison to electrocardiography. The heart beats were measured in 6 healthy volunteers (18 samples) with normal sinus rhythm (NSR) and 16 patients (36 samples) with atrial fibrillation (AF) using both an IR-UWB radar sensor and electrocardiography simultaneously. The participants hold their breath for 20 seconds during the data acquisition. In subjects with NSR, there was excellent agreement of HR (intraclass correlation coefficient [ICC] 0.856), average R-R interval (ICC 0.997) and individual R-R intervals between the two methods (ICC 0.803). In subjects with AF, HR (ICC 0.871) and average R-R interval (ICC 0.925) from the radar sensor also agreed well with those from electrocardiography, though there was a small disagreement in the individual R-R intervals between the two methods (ICC 0.697). The rhythms computed by the signal-processing algorithm showed good agreement between the two methods (Cohen’s Kappa 0.922). The IR-UWB radar sensor is precise and accurate for assessing HR and rhythms in a non-contact fashion.
BackgroundRheumatoid arthritis (RA) has been known to be associated with increased risk of cardiovascular disease (CVD). The aim of this study was to investigate the effects of Tai Chi exercise on CVD risk in elderly women with RA.MethodIn total, 56 female patients with RA were assigned to either a Tai Chi exercise group (29 patients) receiving a 3-month exercise intervention once a week or a control group (27 patients) receiving general information about the benefits of exercise. All participants were assessed at baseline and at 3 months for RA disease activity (Disease Activity Score 28 and Routine Assessment of Patient Index Data 3), functional disability (Health Assessment Questionnaire), CVD risk factors (blood pressure, lipids profile, body composition, and smoking), and three atherosclerotic measurements: carotid intima-media thickness, flow-mediated dilatation (FMD), and brachial-ankle pulse wave velocity (baPWV).ResultsFMD, representative of endothelial function, significantly increased in the Tai Chi exercise group (initial 5.85 ± 2.05 versus 3 months 7.75 ± 2.53 %) compared with the control group (initial 6.31 ± 2.12 versus 3 months 5.78 ± 2.13 %) (P = 1.76 × 10−3). Moreover, baPWV, representative of arterial stiffness, significantly decreased in the Tai Chi exercise group (initial 1693.7 ± 348.3 versus 3 months 1600.1 ± 291.0 cm/s) compared with the control group (initial 1740.3 ± 185.3 versus 3 months 1792.8 ± 326.1 cm/s) (P = 1.57 × 10−2). In addition, total cholesterol decreased significantly in the Tai Chi exercise group compared with the control group (−7.8 ± 15.5 versus 2.9 ± 12.2 mg/dl, P = 2.72 × 10−2); other changes in RA-related characteristics were not significantly different between the two groups. Tai Chi exercise remained significantly associated with improved endothelial function (FMD; P = 4.32 × 10−3) and arterial stiffness (baPWV; P = 2.22 × 10−2) after adjustment for improvement in total cholesterol level.ConclusionTai Chi exercise improved endothelial dysfunction and arterial stiffness in elderly women with RA, suggesting that it can be a useful behavioral strategy for CVD prevention in patients with RA.Electronic supplementary materialThe online version of this article (doi:10.1186/s13075-015-0893-x) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.