Here, we report advanced materials and devices that enable highefficiency mechanical-to-electrical energy conversion from the natural contractile and relaxation motions of the heart, lung, and diaphragm, demonstrated in several different animal models, each of which has organs with sizes that approach human scales. A cointegrated collection of such energy-harvesting elements with rectifiers and microbatteries provides an entire flexible system, capable of viable integration with the beating heart via medical sutures and operation with efficiencies of ∼2%. Additional experiments, computational models, and results in multilayer configurations capture the key behaviors, illuminate essential design aspects, and offer sufficient power outputs for operation of pacemakers, with or without battery assist.biomedical implants | flexible electronics | transfer printing | wearable electronics | heterogeneous integration N early all classes of active wearable and implantable biomedical devices rely on some form of battery power for operation. Heart rate monitors, pacemakers, implantable cardioverterdefibrillators, and neural stimulators together represent a broad subset of bioelectronic devices that provide continuous diagnostics and therapy in this mode. Although advances in battery technology have led to substantial reductions in overall sizes and increases in storage capacities, operational lifetimes remain limited, rarely exceeding a few days for wearable devices and a few years for implants. Surgical procedures to replace the depleted batteries of implantable devices are thus essential, exposing patients to health risks, heightened morbidity, and even potential mortality. The health burden and costs are substantial, and thus motivate efforts to eliminate batteries altogether, or to extend their lifetimes in a significant way.Investigations into energy-harvesting strategies to replace batteries demonstrate several unusual ways to extract power from chemical, mechanical, electrical, and thermal processes in the human body (1, 2). Examples include use of glucose oxidation (3), electric potentials of the inner ear (4), mechanical movements of limbs, and natural vibrations of internal organs (5-7). Such phenomena provide promising opportunities for power supply to wearable and implantable devices (6-8). A recent example involves a hybrid kinetic device integrated with the heart for applications with pacemakers (7). More speculative approaches, based on analytical models of harvesting from pressure-driven deformations of an artery by magneto-hydrodynamics, also exist (9).Cardiac and lung motions, in particular, serve as inexhaustible sources of energy during the lifespan of a patient. Mechanicalto-electrical transduction mechanisms in piezoelectric materials offer viable routes to energy harvesting in such cases, as demonstrated and analyzed by several groups recently (10-17). For example, proposals exist for devices that convert heartbeat vibrations into electrical energy using resonantly coupled motions of thick (1-2 mm) pi...
Existing vital sign monitoring systems in the neonatal intensive care unit (NICU) require multiple wires connected to rigid sensors with strongly adherent interfaces to the skin. We introduce a pair of ultrathin, soft, skin-like electronic devices whose coordinated, wireless operation reproduces the functionality of these traditional technologies but bypasses their intrinsic limitations. The enabling advances in engineering science include designs that support wireless, battery-free operation; real-time, in-sensor data analytics; time-synchronized, continuous data streaming; soft mechanics and gentle adhesive interfaces to the skin; and compatibility with visual inspection and with medical imaging techniques used in the NICU. Preliminary studies on neonates admitted to operating NICUs demonstrate performance comparable to the most advanced clinical-standard monitoring systems.
Summary In vivo optogenetics provides unique, powerful capabilities in the dissection of neural circuits implicated in neuropsychiatric disorders. Conventional hardware for such studies, however, physically tethers the experimental animal to an external light source limiting the range of possible experiments. Emerging wireless options offer important capabilities that avoid some of these limitations, but the current size, bulk, weight, and wireless area of coverage is often disadvantageous. Here, we present a simple but powerful setup based on wireless, near-field power transfer and miniaturized, thin flexible optoelectronic implants, for complete optical control in a variety of behavioral paradigms. The devices combine subdermal magnetic coil antennas connected to microscale, injectable LEDs, with the ability to operate at wavelengths ranging from ultraviolet to blue, green/yellow, and red. An external loop antenna allows robust, straightforward application in a multitude of behavioral apparatuses. The result is a readily mass-producible, user-friendly technology with broad potential for optogenetics applications.
Stretchable, wireless health monitoring patches to evaluate heart rate, blood oximetry, UV exposure, and skin coloration.
This paper describes materials and mechanics aspects of bending in systems consisting of ribbons and bars of single crystalline silicon supported by sheets of plastic. The combined experimental and theoretical results provide an understanding for the essential behaviors and for mechanisms associated with layouts that achieve maximum bendability. Examples of highly bendable silicon devices on plastic illustrate some of these concepts. Although the studies presented here focus on ribbons and bars of silicon, the same basic considerations apply to other implementations of inorganic materials on plastic substrates, ranging from amorphous or polycrystalline thin films, to collections of nanowires and nanoparticles. The contents are, as a result, relevant to the growing community of researchers interested in the use of inorganic materials in flexible electronics.
Transfer printing by kinetically switchable adhesion to an elastomeric stamp shows promise as a powerful micromanufacturing method to pickup microstructures and microdevices from the donor substrate and to print them to the receiving substrate. This can be viewed as the competing fracture of two interfaces. This paper examines the mechanics of competing fracture in a model transfer printing system composed of three laminates: an elastic substrate, an elastic thin film, and a viscoelastic member (stamp). As the system is peeled apart, either the interface between the substrate and thin film fails or the interface between the thin film and the stamp fails. The speed-dependent nature of the film/stamp interface leads to the prediction of a critical separation velocity above which separation occurs between the film and the substrate (i.e., pickup) and below which separation occurs between the film and the stamp (i.e., printing). Experiments verify this prediction using films of gold adhered to glass, and the theoretical treatment extends to consider the competing fracture as it applies to discrete micro-objects. Temperature plays an important role in kinetically controlled transfer printing with its influences, making it advantageous to pickup printable objects at the reduced temperatures and to print them at the elevated ones.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.