On the basis of the derived 100 yr GWPs, the average climate impact per anaesthetic procedure at the University of Michigan is the same as the emission of ∼22 kg CO(2). We estimate that the global emissions of inhalation anaesthetics have a climate impact which is comparable with that from the CO(2) emissions from one coal-fired power plant or 1 million passenger cars.
Pulse oximeter arterial hemoglobin oxygen saturation (SpO2) and finger arterial pressure (FINAP) were continuously monitored before, during, and after cardiopulmonary bypass in 15 male patients. SpO2 was monitored simultaneously with two pulse oximeters, a Nellcor N-100 and an Ohmeda Biox III. The readings obtained from the two pulse oximeters were compared with arterial blood measurements obtained using a CO-oximeter. FINAP was monitored by a prototype device (Finapres) based on the Penaz volume-clamp method. FINAP was correlated with intraarterial pressure (IAP). Both pulse oximeters functioned well before cardiopulmonary bypass. The correlations with CO-oximeter values were 0.927 for the N-100 and 0.921 for the Biox III. Immediately after the onset of cardiopulmonary bypass, the N-100 pulse oximeter stopped displaying values. The Biox III pulse oximeter continued to display values during the cardiopulmonary bypass period; the correlation with CO-oximeter values was 0.813. After cardiopulmonary bypass, the N-100 began displaying values in 2 to 10 minutes. After cardiopulmonary bypass the correlation with CO-oximeter values was 0.792 for the N-100 and 0.828 for the Biox III pulse oximeter. The Finapres finger blood pressure device functioned well in 13 of 15 patients before cardiopulmonary bypass. The mean bias +/- precision of FINAP-IAP for mean pressure was 8.3 +/- 10.2 mm Hg (SD) and the correlation coefficient was 0.814. During cardiopulmonary bypass, the Finapres device functioned well in 10 of 15 patients. The mean bias precision of FINAP-IAP, for mean pressure in these 10 patients was 6.6 +/- 8.7 mm Hg and the correlation coefficient was 0.902.(ABSTRACT TRUNCATED AT 250 WORDS)
Using aperiodic analysis, we compared the EEG produced by alfentanil with the EEGs produced by two other opiates--fentanyl and sufentanil--on the one hand and with the EEG produced by a barbiturate--thiopental--on the other hand. Alfentanil and thiopental were injected over 1 minute; fentanyl and sufentanil were injected over 10 to 15 minutes. From the aperiodic analysis we derived up to seven single-number variables computed over 30- or 60-second epochs. All the opiates induced EEGs that were qualitatively similar to each other, although the maximum or minimum values tended to be greater and the time course more rapid with alfentanil than with the other two opiates. This finding may have been related to the fact that we injected relatively more alfentanil and administered it more rapidly. The EEGs produced by alfentanil and thiopental differed markedly, both qualitatively and quantitatively. The total power at 1 Hz and cumulative power at 3 Hz went to higher peak values with alfentanil, the latter tending to decrease with thiopental. The total number of waves per epoch went to lower peak values with alfentanil; there was little change with thiopental. The frequency below which 90% of the power resides went to considerably lower peak values with alfentanil than with thiopental. Finally, total power at 10 to 12 Hz (alpha waves) and average power at 17 to 19 Hz (beta waves) went to very high peak values with thiopental, but decreased with alfentanil.(ABSTRACT TRUNCATED AT 250 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.