PBM has positive effects on MSCs. This review concluded that doses of 0.7-4 J/cm and wavelengths of 600-700 nm are appropriate for light therapy. The results were dependent upon different parameters; therefore, optimization of parameters used in light therapy to obtain favorable results is required to provide more accurate comparison.
Background: Tissue engineering aims to take advantage of the ability of undifferentiated stem cells to differentiate into multiple cell types to repair damaged tissue. Photobiomodulation uses either lasers or light-emitting diodes to promote stem cell proliferation and differentiation. The present study aimed to investigate single and dual combinations of laser wavelengths on mesenchymal stem cells (MSCs). Materials and Methods: MSCs were derived from rabbit iliac bone marrow. One control and 8 laser irradiated groups were designated as: Infra-red (IR, 810nm), Red (R, 660 nm), Green (G, 532 nm), Blue (B, 485 nm), IR-R, IR-B, R-G, B-G. Irradiation was repeated daily for 21 days and cell proliferation, osseous or cartilaginous differentiation was then measured. RT-PCR biomarkers were SOX9, aggrecan, COL 2 and COL 10 expression for cartilage and ALP, COL 1 and osteocalcin expression for bone. Results: Cellular proliferation was increased in all irradiated groups except G. All cartilage markers were significantly increased by IR and IR-B except COL 10 which was suppressed by IR-B combination. ALP expression was highest in R and IR groups during osseous differentiation.
Highlights:
Photobiomodulation (PBM) can reduce lung edema, cytokines in bronchoalveolar parenchyma, neutrophil influx.
PBM reduces TNF-α, IL-1β, IL-6, ICAM-1, MIP-2 and Reactive oxygen species.
Transthoracic approach is the direct methods for reducing lung inflammation.
Intravenous approach increases the oxygenation of red blood cells.
Background:Curcumin is the most active compound in turmeric. It can suppress the nuclear factor kappa-light-chain-enhancer of activated B cells pathway and prevent the osteoclastogenesis procedure. This study aimed to be the first to evaluate the effect of curcumin on the rate of orthodontic tooth movement (OTM).Materials and Methods:Forty rats were used as follows in each group: (1) negative control: Did not receive any appliance or injection; (2) positive control: received 0.03 cc normal saline and appliance; (3) gelatin plus curcumin (G): Received 0.03 cc hydrogel and appliance; and (4) chitosan plus curcumin (Ch): Received 0.03 cc hydrogel and appliance. They were anesthetized and closed nickel-titanium coil springs were installed between the first molars and central incisors unilaterally as the orthodontic appliance. After 21 days, the rats were decapitated, and the distance between the first and second molars was measured by a leaf gauge. Howship's lacunae, blood vessels, osteoclast-like cells, and root resorption lacunae were evaluated in the histological analysis. Data were analyzed by one-way ANOVA, Tukey's test, and t-test (P < 0.05 consider significant).Results:No significant difference was found in OTM between groups delivered orthodontic forces. Curcumin inhibited root and bone resorption, osteoclastic recruitment, and angiogenesis significantly.Conclusion:Curcumin had no significant inhibitory effect on OTM. While it had a significant role on decreasing bone or root resorption (P > 0.05).
Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials.Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA.Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties.Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.