A method is developed to estimate global NO2 and SO2 dry deposition fluxes at high spatial resolution (0.1°×0.1°) using satellite measurements from the Ozone Monitoring Instrument (OMI) on the Aura satellite, in combination with simulations from the Goddard Earth Observing System chemical transport model (GEOS‐Chem). These global maps for 2005–2007 provide a data set for use in examining global and regional budgets of deposition. In order to properly assess SO2 on a global scale, a method is developed to account for the geospatial character of background offsets in retrieved satellite columns. Globally, annual dry deposition to land estimated from OMI as NO2 contributes 1.5 ± 0.5 Tg of nitrogen and as SO2 contributes 13.7 ± 4.0 Tg of sulfur. Differences between OMI‐inferred NO2 dry deposition fluxes and those of other models and observations vary from excellent agreement to an order of magnitude difference, with OMI typically on the low end of estimates. SO2 dry deposition fluxes compare well with in situ Clear Air Status and Trends Network‐inferred flux over North America (slope = 0.98, r = 0.71). The most significant NO2 dry deposition flux to land per area occurs in the Pearl River Delta, China, at 13.9 kg N ha−1 yr−1, while SO2 dry deposition has a global maximum rate of 72.0 kg S ha−1 yr−1 to the east of Jinan in China's Shandong province. Dry deposition fluxes are explored in several urban areas, where NO2 contributes on average 9–36% and as much as 85% of total NOy dry deposition.
Noncontact with the test specimen is the advantage of Electromagnetic Acoustic Transducer(EMAT), but it lowers the efficiency of EMAT, because the lift-off of transducer reduces the magnitude of alternating magnetic field in the specimen which has close relationship with exciting and receiving ultrasonic signals. The distribution and intensity of the alternating magnetic field at different lift-off values are simulated with the software of ANSOFT, and the relationship between lift-off and received signals is analyzed by experiments. Results show that the lift-off of transmitter should be about 2mm.
This paper proposes a new omni-directional electromagnetic acoustic transducer (EMAT) for the ultrasonic Lamb wave (ULW) tomography imaging (TI) of defects in metallic plates. The proposed EMAT is composed of a permanent magnet and a coil with a contra-flexure structure. This new EMAT coil structure is used for omni-directional ULW transmission and reception and ULW TI for the first time. The theoretical background and the working principles of this EMAT are presented and analyzed. The experimental results of its use on a 3 mm thick aluminum plate indicate that the EMAT with a contra-flexure coil (CFC) can transmit and receive a pure single A0 mode ULW with a high signal-to-noise ratio (SNR). Thus, the extraction of the projection data used for ULW TI may be performed accurately. The circumferential consistency of the projection data is only slightly influenced by the distortion of the eddy current field that is induced by the new CFC with an irregular shape. When the new EMAT array is used for ULW TI using the cross-hole method and SIRT arithmetic, a desirable imaging quality can be achieved, and the estimated size of an artificial corrosion defect agreed well with its actual value. The relation between the reconstruction resolution and the number of the new EMATs used is analyzed. More TI experiments are carried out when the aluminum plate defect is in two different locations relative to the EMAT array, for the further investigation of the performances of the new EMATs.
Sampling technology has been widely deployed in measurement systems to control memory consumption and processing overhead. However, most of the existing sampling methods suffer from large estimation errors in analyzing small-size flows. To address the problem, we propose a novel adaptive non-linear sampling (ANLS) method for passive measurement. Instead of statically configuring the sampling rate, ANLS dynamically adjusts the sampling rate for a flow depending on the number of packets having been counted. We provide the generic principles guiding the selection of sampling function for sampling rate adjustment. Moreover, we derive the unbiased flow size estimation, the bound of the relative error, and the bound of required counter size for ANLS. The performance of ANLS is thoroughly studied through theoretic analysis and experiments under synthetic/real network data traces, with comparison to several related sampling methods. The results demonstrate that the proposed ANLS can significantly improve the estimation accuracy, particularly for small-size flows, while maintain a memory and processing overhead comparable to existing methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.