Different implant placement depths do not influence crestal bone changes. Soft tissue behavior is not influenced by different implant placement depths or by the amount of keratinized tissue.
An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (τ), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey's test and correlation tests were performed using Pearson's rank correlation (α = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 ± 9.05 μm), Co-Cr (66.41 ± 35.47 μm) and Ni-Cr-Ti (32.20 ± 24.47 μm). Stresses generated by Co-Cr alloy (τ = 7.70 ± 2.16 kPa) were significantly higher than those generated by CP Ti (τ = 5.86 ± 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (τ = 5.74 ± 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials.
Objectives
This randomized clinical trial analyzed the long‐term (5‐year) crestal bone changes and soft tissue dimensions surrounding implants with an internal tapered connection placed in the anterior mandibular region at different depths (equi‐ and subcrestal).
Materials and methods
Eleven edentulous patients were randomly divided in a split‐mouth design: 28 equicrestal implants (G1) and 27 subcrestal (1–3 mm) implants (G2). Five implants were placed per patient. All implants were immediately loaded. Standardized intraoral radiographs were used to evaluate crestal bone (CB) changes. Patients were assessed immediately, 4, 8, and 60 months after implant placement. The correlation between vertical mucosal thickness (VMT) and soft tissue recession was analyzed. Sub‐group analysis was also performed to evaluate the correlation between VMT and CB loss. Rank‐based ANOVA was used for comparison between groups (α = .05).
Results
Fifty‐five implants (G1 = 28 and G2 = 27) were assessed. Implant and prosthetic survival rate were 100%. Subcrestal positioning resulted in less CB loss (−0.80 mm) when compared to equicrestal position (−0.99 mm), although the difference was not statistically significant (p > .05). Significant CB loss was found within the G1 and G2 groups at two different measurement times (T4 and T60) (p < .05). Implant placement depths and VMT had no effect on soft tissue recession (p > .05).
Conclusions
There was no statistically significant difference in CB changes between subcrestal and equicrestal implant positioning; however, subcrestal position resulted in higher bone levels. Neither mucosal recession nor vertical mucosa thickness was influenced by different implant placement depths.
This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.