2008
DOI: 10.1590/s0103-64402008000400013
|View full text |Cite
|
Sign up to set email alerts
|

Relation between implant/abutment vertical misfit and torque loss of abutment screws

Abstract: This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit obser… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

5
21
0
13

Year Published

2010
2010
2017
2017

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 49 publications
(44 citation statements)
references
References 10 publications
5
21
0
13
Order By: Relevance
“…This is in agreement with other studies (6,17). Perfectly fitting multi-unit implant dentures have been a theoretical ideal, but hardly achievable clinically.…”
Section: Discussionsupporting
confidence: 93%
“…This is in agreement with other studies (6,17). Perfectly fitting multi-unit implant dentures have been a theoretical ideal, but hardly achievable clinically.…”
Section: Discussionsupporting
confidence: 93%
“…These findings may be explained by the reduction of the torque values after casting procedures and the presence of roughness and irregularities on the contact surface 2 . The misfit between implant and abutment increases stress on the screw and results in metal fatigue failure and screw loosening [10][11] . Even the smallest misfit could result in changes in screw geometry and cause incidence of strain on the screws 12 .…”
Section: Discussionmentioning
confidence: 99%
“…[1345] The most frequently observed complication of screwed and cemented prostheses is loosening of the screw that leads to a misfit of the abutment to the implant after the prosthesis is in use. [13456] The combination of horizontal and vertical misfits may result in a gap leading to an increased area of bacterial accumulation, which complicates clean-up[78] and causes gingival inflammation due to the development of microflora in the gap region. Peri-implantitis and subsequent risks of bone resorption as well as posterior fracture of the screw can develop.…”
Section: Introductionmentioning
confidence: 99%