Active amplifiers within the cochlea generate, as a by-product of their function, distortion-product otoacoustic emissions (DPOAEs) in response to specific two-tone stimuli. Focus has been on invoking emissions in a mid-frequency range from ∼0.5 to 4 kHz. The present study investigates stimulus parameters of the DPOAE at 2f1-f2 frequencies below 0.5 kHz. Eighteen out of 21 young human adults screened had audiometrically normal hearing for inclusion in the experiment. DPOAEs were measured with pure-tone stimuli in four configurations: f2 fixed around 2.13 kHz, f2 fixed around 0.53 kHz, 2f1-f2 fixed at 1.23 kHz and 0.25 kHz. Eight stimulus ratios, f2/f1, and three stimulus sound pressure levels, L1/L2, were measured in each configuration. Trends in ratio-magnitude responses for the mid-frequency DPOAE agree with those reported in previous literature. DPOAEs are not limited to distortion frequencies >0.5 kHz, but the stimulus ratio invoking the largest DPOAE in the mid-frequency range does not do so in the low-frequency range. Guiding the ratio according to the equivalent rectangular bandwidth of auditory filters maintains the DPOAE level.
The effects of overexposure on the properties of distortion product otoacoustic emissions (DPOAEs) are investigated. In total, 39 normal-hearing humans were monaurally exposed to a 1-kHz tone lasting for 3 min at an equivalent threshold sound-pressure level of 105.5 dB. The effects of overexposure were studied in two experiments (1) on the broadband DPOAE and (2) on the DPOAE fine structure, measured using a higher frequency resolution in a narrower frequency range. The obtained DPOAE shifts were compared to temporary threshold shift (TTS) obtained after a similar exposure. Similarities between DPOAE shifts and TTS were found in the affected frequency range and the time course of recovery. The amount of TTS was higher in the early recovery time (1-4-min postexposure), but similar to the DPOAE shift (even in absolute terms) at later recovery times (5-20-min postexposure). The DPOAE fine structure was not systematically changed after the exposure.
Purpose
The aim of this study was to develop a tool to gain insight into the daily experiences of new hearing aid users and to shed light on aspects of aided performance that may not be unveiled through standard questionnaires.
Method
The tool is developed based on clinical observations, patient experiences, expert involvement, and existing validated hearing rehabilitation questionnaires.
Results
An online tool for collecting data related to hearing aid use was developed. The tool is based on 453 prefabricated sentences representing experiences within 13 categories related to hearing aid use.
Conclusions
The tool has the potential to reflect a wide range of individual experiences with hearing aid use, including auditory and nonauditory aspects. These experiences may hold important knowledge for both the patient and the professional in the hearing rehabilitation process.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.