Abstract-A method for the automatic processing of the electrocardiogram (ECG) for the classification of heartbeats is presented. The method allocates manually detected heartbeats to one of the five beat classes recommended by ANSI/AAMI EC57:1998 standard, i.e., normal beat, ventricular ectopic beat (VEB), supraventricular ectopic beat (SVEB), fusion of a normal and a VEB, or unknown beat type. Data was obtained from the 44 nonpacemaker recordings of the MIT-BIH arrhythmia database. The data was split into two datasets with each dataset containing approximately 50 000 beats from 22 recordings. The first dataset was used to select a classifier configuration from candidate configurations. Twelve configurations processing feature sets derived from two ECG leads were compared. Feature sets were based on ECG morphology, heartbeat intervals, and RR-intervals. All configurations adopted a statistical classifier model utilizing supervised learning. The second dataset was used to provide an independent performance assessment of the selected configuration. This assessment resulted in a sensitivity of 75.9%, a positive predictivity of 38.5%, and a false positive rate of 4.7% for the SVEB class. For the VEB class, the sensitivity was 77.7%, the positive predictivity was 81.9%, and the false positive rate was 1.2%. These results are an improvement on previously reported results for automated heartbeat classification systems.Index Terms-Electrocardiogram (ECG), heartbeat classifier, linear discriminant analysis, statistical classifier model.
Abstract-An adaptive system for the automatic processing of the electrocardiogram (ECG) for the classification of heartbeats into one of the five beat classes recommended by ANSI/AAMI EC57:1998 standard is presented. The heartbeat classification system processes an incoming recording with a global-classifier to produce the first set of beat annotations. An expert then validates and if necessary corrects a fraction of the beats of the recording. The system then adapts by first training a local-classifier using the newly annotated beats and combines this with the global-classifier to produce an adapted classification system. The adapted system is then used to update beat annotations. The results of this study show that the performance of a patient adaptable classifier increases with the amount of training of the system on the local record. Crucially, the performance of the system can be significantly boosted with a small amount of adaptation even when all beats used for adaptation are from a single class. This study illustrates the ability to provide highly beneficial automatic arrhythmia monitoring and is an improvement on previously reported results for automated heartbeat classification systems.Index Terms-Adaptive classifier, ECG, heartbeat classifier, linear discriminant analysis, statistical classifier model.
Sleep apnoea is a common disorder that is usually diagnosed through expensive studies conducted in sleep laboratories. Sleep apnoea is accompanied by a characteristic cyclic variation in heart rate or other changes in the waveform of the electrocardiogram (ECG). If sleep apnoea could be diagnosed using only the ECG, it could be possible to diagnose sleep apnoea automatically and inexpensively from ECG recordings acquired in the patient's home. This study had two parts. The first was to assess the ability of an overnight ECG recording to distinguish between patients with and without apnoea. The second was to assess whether the ECG could detect apnoea during each minute of the recording. An expert, who used additional physiological signals, assessed each of the recordings for apnoea. Research groups were invited to access data via the world-wide web and submit algorithm results to an international challenge linked to a conference. A training set of 35 recordings was made available for algorithm development, and results from a test set of 35 different recordings were made available for independent scoring. Thirteen algorithms were compared. The best algorithms made use of frequency-domain features to estimate changes in heart rate and the effect of respiration on the ECG waveform. Four of these algorithms achieved perfect scores of 100% in the first part of the study, and two achieved an accuracy of over 90% in the second part of the study.
A method for the automatic processing of the electrocardiogram (ECG) for the detection of obstructive apnoea is presented. The method screens nighttime single-lead ECG recordings for the presence of major sleep apnoea and provides a minute-by-minute analysis of disordered breathing. A large independently validated database of 70 ECG recordings acquired from normal subjects and subjects with obstructive and mixed sleep apnoea, each of approximately eight hours in duration, was used throughout the study. Thirty-five of these recordings were used for training and 35 retained for independent testing. A wide variety of features based on heartbeat intervals and an ECG-derived respiratory signal were considered. Classifiers based on linear and quadratic discriminants were compared. Feature selection and regularization of classifier parameters were used to optimize classifier performance. Results show that the normal recordings could be separated from the apnoea recordings with a 100% success rate and a minute-by-minute classification accuracy of over 90% is achievable.
A system for remotely detecting vocal fold pathologies using telephone-quality speech is presented. The system uses a linear classifier, processing measurements of pitch perturbation, amplitude perturbation and harmonic-to-noise ratio derived from digitized speech recordings. Voice recordings from the Disordered Voice Database Model 4337 system were used to develop and validate the system. Results show that while a sustained phonation, recorded in a controlled environment, can be classified as normal or pathologic with accuracy of 89.1%, telephone-quality speech can be classified as normal or pathologic with an accuracy of 74.2%, using the same scheme. Amplitude perturbation features prove most robust for telephone-quality speech. The pathologic recordings were then subcategorized into four groups, comprising normal, neuromuscular pathologic, physical pathologic and mixed (neuromuscular with physical) pathologic. A separate classifier was developed for classifying the normal group from each pathologic subcategory. Results show that neuromuscular disorders could be detected remotely with an accuracy of 87%, physical abnormalities with an accuracy of 78% and mixed pathology voice with an accuracy of 61%. This study highlights the real possibility for remote detection and diagnosis of voice pathology.
The development of a system for automatically sorting a database of shoeprint images based on the outsole pattern in response to a reference shoeprint image is presented. The database images are sorted so that those from the same pattern group as the reference shoeprint are likely to be at the start of the list. A database of 476 complete shoeprint images belonging to 140 pattern groups was established with each group containing two or more examples. A panel of human observers performed the grouping of the images into pattern categories. Tests of the system using the database showed that the first-ranked database image belongs to the same pattern category as the reference image 65 percent of the time and that a correct match appears within the first 5 percent of the sorted images 87 percent of the time. The system has translational and rotational invariance so that the spatial positioning of the reference shoeprint images does not have to correspond with the spatial positioning of the shoeprint images of the database. The performance of the system for matching partial-prints was also determined.
SUMMARYWe studied a novel non-contact biomotion sensor, which has been developed for identifying sleep ⁄ wake patterns in adult humans. The biomotion sensor uses ultra lowpower reflected radiofrequency waves to determine the movement of a subject during sleep. An automated classification algorithm has been developed to recognize sleep ⁄ wake states on a 30-s epoch basis based on the measured movement signal. The sensor and software were evaluated against gold-standard polysomnography on a database of 113 subjects [94 male, 19 female, age 53 ± 13 years, apnoea-hypopnea index (AHI) 22 ± 24] being assessed for sleep-disordered breathing at a hospital-based sleep laboratory. The overall per-subject accuracy was 78%, with a Cohen's kappa of 0.38. Lower accuracy was seen in a high AHI group (AHI >15, 63 subjects) than in a low AHI group (74.8% versus 81.3%); however, most of the change in accuracy can be explained by the lower sleep efficiency of the high AHI group. Averaged across subjects, the overall sleep sensitivity was 87.3% and the wake sensitivity was 50.1%. The automated algorithm slightly overestimated sleep efficiency (bias of +4.8%) and total sleep time (TST; bias of +19 min on an average TST of 288 min). We conclude that the non-contact biomotion sensor can provide a valid means of measuring sleep-wake patterns in this patient population, and also allows direct visualization of respiratory movement signals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.