Difficulty with turning is a major contributor to mobility disability and falls in people with movement disorders, such as Parkinson's disease (PD). Turning often results in freezing and/or falling in patients with PD. However, asking a patient to execute a turn in the clinic often does not reveal their impairments. Continuous monitoring of turning with wearable sensors during spontaneous daily activities may help clinicians and patients determine who is at risk of falls and could benefit from preventative interventions. In this study, we show that continuous monitoring of natural turning with wearable sensors during daily activities inside and outside the home is feasible for people with PD and elderly people. We developed an algorithm to detect and characterize turns during gait, using wearable inertial sensors. First, we validate the turning algorithm in the laboratory against a Motion Analysis system and against a video analysis of 21 PD patients and 19 control (CT) subjects wearing an inertial sensor on the pelvis. Compared to Motion Analysis and video, the algorithm maintained a sensitivity of 0.90 and 0.76 and a specificity of 0.75 and 0.65, respectively. Second, we apply the turning algorithm to data collected in the home from 12 PD and 18 CT subjects. The algorithm successfully detects turn characteristics, and the results show that, compared to controls, PD subjects tend to take shorter turns with smaller turn angles and more steps. Furthermore, PD subjects show more variability in all turn metrics throughout the day and the week.
Sleep apnoea is a common disorder that is usually diagnosed through expensive studies conducted in sleep laboratories. Sleep apnoea is accompanied by a characteristic cyclic variation in heart rate or other changes in the waveform of the electrocardiogram (ECG). If sleep apnoea could be diagnosed using only the ECG, it could be possible to diagnose sleep apnoea automatically and inexpensively from ECG recordings acquired in the patient's home. This study had two parts. The first was to assess the ability of an overnight ECG recording to distinguish between patients with and without apnoea. The second was to assess whether the ECG could detect apnoea during each minute of the recording. An expert, who used additional physiological signals, assessed each of the recordings for apnoea. Research groups were invited to access data via the world-wide web and submit algorithm results to an international challenge linked to a conference. A training set of 35 recordings was made available for algorithm development, and results from a test set of 35 different recordings were made available for independent scoring. Thirteen algorithms were compared. The best algorithms made use of frequency-domain features to estimate changes in heart rate and the effect of respiration on the ECG waveform. Four of these algorithms achieved perfect scores of 100% in the first part of the study, and two achieved an accuracy of over 90% in the second part of the study.
Background Difficulty turning during gait is a major contributor to mobility disability, falls and reduced quality of life in patients with Parkinson’s disease (PD). Unfortunately, the assessment of mobility in the clinic may not adequately reflect typical mobility function or its variability during daily life. We hypothesized that quality of turning mobility, rather than overall quantity of activity, would be impaired in people with PD over 7 days of continuous recording. Methods 13 subjects with PD and 8 healthy control subjects of similar age wore 3 Opal inertial sensors (on their belt and on each foot) throughout 7 consecutive days during normal daily activities. Turning metrics included average and coefficient of variation (CV) of: 1) number of turns per hour, 2) turn angle amplitude, 3) turn duration, 4) turn mean velocity, and 5) number of steps per turn. Turning characteristics during continuous monitoring were compared with turning 90 and 180 degrees in a observed gait task. Results No differences were found between PD and control groups for observed turns. In contrast, subjects with PD showed impaired quality of turning compared to healthy control subjects (Turn Mean Velocity: 43.3±4.8°/s versus 38±5.7°/s, mean number of steps 1.7±1.1 versus 3.2±0.8). In addition, PD patients showed higher variability within the day and across days compared to controls. However, no differences were seen between PD and control subjects in the overall activity (number of steps per day or percent of the day walking) during the 7 days. Conclusions We show that continuous monitoring of natural turning during daily activities inside or outside the home is feasible for patients with PD and the elderly. This is the first study showing that continuous monitoring of turning was more sensitive to PD than observed turns. In addition, the quality of turning characteristics was more sensitive to PD than quantity of turns. Characterizing functional turning during daily activities will address a critical barrier to rehabilitation practice and clinical trials: objective measures of mobility characteristics in real-life environments.
Wearable inertial systems have recently been used to track human movement in and outside of the laboratory. Continuous monitoring of human movement can provide valuable information relevant to individuals' level of physical activity and functional ability. Traditionally, orientation has been calculated by integrating the angular velocity from gyroscopes. However, a small drift in the measured velocity leads to increasing integration error over time. To compensate that drift, complementary data from accelerometers are normally fused into tracking systems using the Kalman or extended Kalman filter. In this study, we combine kinematic models designed for control of robotic arms with state-space methods to continuously estimate the angles of human shoulder and elbow using two wearable inertial measurement units. We use the unscented Kalman filter to implement the nonlinear state-space inertial tracker. Shoulder and elbow joint angles obtained from 8 subjects using our inertial tracker were compared to the angles obtained from an optical-tracking reference system. On average, there was an RMS angle error of less than 8° for all shoulder and elbow angles. The average correlation coefficient for all movement tasks among all subjects was r ≥ 0.95 . This agreement between our inertial tracker and the optical reference system was obtained for both regular and fast-speed movement of the arm. The same method can be used to track movement of other joints.
Beat detection algorithms have many clinical applications including pulse oximetry, cardiac arrhythmia detection, and cardiac output monitoring. Most of these algorithms have been developed by medical device companies and are proprietary. Thus, researchers who wish to investigate pulse contour analysis must rely on manual annotations or develop their own algorithms. We designed an automatic detection algorithm for pressure signals that locates the first peak following each heart beat. This is called the percussion peak in intracranial pressure (ICP) signals and the systolic peak in arterial blood pressure (ABP) and pulse oximetry (SpO2) signals. The algorithm incorporates a filter bank with variable cutoff frequencies, spectral estimates of the heart rate, rank-order nonlinear filters, and decision logic. We prospectively measured the performance of the algorithm compared to expert annotations of ICP, ABP, and SpO2 signals acquired from pediatric intensive care unit patients. The algorithm achieved a sensitivity of 99.36% and positive predictivity of 98.43% on a dataset consisting of 42,539 beats.
Traditionally, human movement has been captured primarily by motion capture systems. These systems are costly, require fixed cameras in a controlled environment, and suffer from occlusion. Recently, the availability of low-cost wearable inertial sensors containing accelerometers, gyroscopes, and magnetometers have provided an alternative means to overcome the limitations of motion capture systems. Wearable inertial sensors can be used anywhere, cannot be occluded, and are low cost. Several groups have described algorithms for tracking human joint angles. We previously described a novel approach based on a kinematic arm model and the Unscented Kalman Filter (UKF). Our proposed method used a minimal sensor configuration with one sensor on each segment. This paper reports significant improvements in both the algorithm and the assessment. The new model incorporates gyroscope and accelerometer random drift models, imposes physical constraints on the range of motion for each joint, and uses zero-velocity updates to mitigate the effect of sensor drift. A high-precision industrial robot arm precisely quantifies the performance of the tracker during slow, normal, and fast movements over continuous 15-min recording durations. The agreement between the estimated angles from our algorithm and the high-precision robot arm reference was excellent. On average, the tracker attained an RMS angle error of about 3(°) for all six angles. The UKF performed slightly better than the more common Extended Kalman Filter.
We studied changes in intracranial pressure (ICP) complexity, estimated by the approximate entropy (ApEn) of the ICP signal, as subjects progressed from a state of normal ICP (< 20-25 mmHg) to acutely elevated ICP (an ICP "spike" defined as ICP > 25 mmHg for < or = 5 min). We hypothesized that the measures of intracranial pressure (ICP) complexity and irregularity would decrease during acute elevations in ICP. To test this hypothesis we studied ICP spikes in pediatric subjects with severe traumatic brain injury (TBI). We conclude that decreased complexity of ICP coincides with episodes of intracranial hypertension (ICH) in TBI. This suggests that the complex regulatory mechanisms that govern intracranial pressure are disrupted during acute rises in ICP. Furthermore, we carried out a series of experiments where ApEn was used to analyze synthetic signals of different characteristics with the objective of gaining a better understanding of ApEn itself, especially its interpretation in biomedical signal analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.