Dual isotope pinhole subtraction PS has higher diagnostic accuracy compared with dual-phase PS, 4D-CT, and US as a first-line imaging study in primary hyperparathyroidism. In case of a negative scintigraphy or suspicion of multiglandular disease, 4D-CT and/or US is recommended as a second-line modality. However, diagnostic algorithms should be adapted in accordance with local availability and expertise.
Primary hyperparathyroidism (pHPT) is almost exclusively the result of a solitary parathyroid adenoma. In most cases, the affected gland can be surgically removed, but precise preoperative imaging is essential for adenoma localization prior to surgical intervention. In this study, we evaluated the diagnostic value of four-dimensional computed tomography (4D-CT) as a preoperative imaging tool in relation to the localization of pathologic parathyroid glands in patients with pHPT and negative sestamibi scans. This study included 43 consecutive patients with pHPT referred for parathyroidectomy at the Department of Head and Neck Surgery of Copenhagen University Hospital Rigshospitalet in 2011 and 2012. All patients had a 4D-CT performed prior to parathyroidectomy. CT localization of the suspected adenoma was correlated to the actual surgical findings and subsequent histological diagnosis was also available as references for the accuracy of this imaging tool. Hyperfunctioning parathyroid glands were found in 40 patients. 4D-CT identified 32 solitary hyperfunctioning parathyroid glands located on the correct side of the neck (PPV 76 %) and 21 located within the correct quadrant (PPV 49 %). Unilateral resection was performed in 72 % of patients due to the localization findings of preoperative imaging. 4D-CT can, therefore, be considered an effective method for the preoperative localization of parathyroid adenomas and is an important tool in surgical intervention for patients referred to parathyroidectomy.
MR accurately demonstrates the anatomy of the spine and spinal cord, showing the level and complexity of spinal lesions. Multiple lesions may be underestimated when the combination of myelography/radiculography and CT is used.
The use of IBC for CT-guided lung biopsy was not an advantage for unselected patients in our care, since it did not improve the biopsy accuracy and the risk of pneumothorax was increased.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.