A sensitive, selective, and validated HPLC-diode-array detection method was developed for the simultaneous determination of five neonicotinoid insecticides-acetamiprid, imidacloprid, nitenpyram, flonicamid, and thiacloprid-and their primary metabolite, 6-chloronicotinic acid, in cucumbers and soil based on the quick, easy, cheap, effective, rugged, and safe (QuEChERS) technique as a pretreatment procedure. In the QuEChERS procedure, cucumber samples were extracted with acetonitrile and cleaned using C18, whereas soil samples were extracted with an acetonitrile-dichloromethane mixture (1 + 2). The HPLC conditions were optimized by separating neonicotinoids using an acetonitrile-water mixture (25 + 75) and a Synergi Hydro RP C18 column. Matrix-matched calibration standards were prepared in cucumber and soil to eliminate any matrix interference. RSDs were ≤9% in all recovery tests. LODs and LOQs for the five neonicotinoids were in the ranges of 0.006-0.122 and 0.018-0.366 μg/g, respectively. This method was successfully applied to determine residues, the rate of disappearance of the five neonicotinoids from cucumber and soil, and the half-lives of the neonicotinoids.
A new method was developed for the simultaneous determination of three neonicotinoid insecticides with their metabolite in cucumbers and soil based on QuEChERS as a pretreatment procedure.
Two sensitive, selective, and precise methods for the determination of pyriproxyfen and pyridalyl insecticide residues in tomatoes have been developed. The first method is HPLC with UV detection in which pyriproxyfen and pyridalyl were extracted with ethyl acetate and acetone, respectively, followed by cleanup using column chromatography. The recoveries ranged from 86.03 to 94.55 for pyriproxyfen and 95.08 to 99.38% for pyridalyl in tomato samples. The LOD of the method was 0.217 ppm for pyriproxyfen and 0.1866 ppm for pyridalyl. The second method depends on direct fluorometric determination of pyriproxyfen and pyridalyl in acetic and sulfuric acid at excitation and emission wavelengths of 320 and 646 nm, respectively. The recoveries of pyriproxyfen and pyridalyl in tomato samples ranged from 88 to 98% and 86 to 93%, respectively. The LOD of the method was 0.146 ppm for pyriproxyfen and 0.078 ppm for pyridalyl. Both methods were applied successfully to determine residues and rate of disappearance of pyriproxyfen and pyridalyl from tomatoes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.