The treatment of bone loss due to different etiologic factors is difficult, and many techniques aim to improve repair, including a wide range of biomaterials and, recently, photobioengineering. This work aimed to assess, through Raman spectroscopy, the level of bone mineralization using the intensities of the Raman peaks of both inorganic (∼ 960, ∼ 1,070, and ∼ 1,077 cm(-1)) and organic (∼ 1,454 and ∼ 1,666 cm(-1)) contents of bone tissue. Forty rats were divided into four groups each subdivided into two subgroups according to the time of killing (15 and 30 days). Surgical bone defects were made on femur of each animal with a trephine drill. On animals of group Clot, the defect was filled only by blood clot; on group Laser, the defect filled with the clot was further irradiated. On animals of groups Biomaterial and Laser + Biomaterial, the defect was filled by biomaterial and the last one was further irradiated (λ780 nm, 70 mW, Φ ∼ 0.4 cm(2), 20 J/cm(2) session, 140 J/cm(2) treatment) in four points around the defect at 48-h intervals and repeated for 2 weeks. At both 15th and 30th day following killing, samples were taken and analyzed by Raman spectroscopy. At the end of the experimental time, the intensities of both inorganic and organic contents were higher on group Laser + Biomaterial. It is concluded that the use of laser phototherapy associated to biomaterial was effective in improving bone healing on bone defects as a result of the increasing deposition of calcium hydroxyapatite measured by Raman spectroscopy.
We studied peaks of calcium hydroxyapatite (CHA) and protein and lipid CH groups in defects grafted with mineral trioxide aggregate (MTA) treated or not with LED irradiation, bone morphogenetic proteins and guided bone regeneration. A total of 90 rats were divided into ten groups each of which was subdivided into three subgroups (evaluated at 15, 21 and 30 days after surgery). Defects were irradiated with LED light (wavelength 850 ± 10 nm) at 48-h intervals for 15 days. Raman readings were taken at the surface of the defects. There were no statistically significant differences in the CHA peaks among the nonirradiated defects at any of the experimental time-points. On the other hand, there were significant differences between the defects filled with blood clot and the irradiated defects at all time-points (p < 0.001, p = 0.02, p < 0.001). There were significant differences between the mean peak CHA in nonirradiated defects at all the experimental time-points (p < 0.01). The mean peak of the defects filled with blood clot was significantly different from that of the defects filled with MTA (p < 0.001). There were significant differences between the defects filled with blood clot and the irradiated defects (p < 0.001). The results of this study using Raman spectral analysis indicate that infrared LED light irradiation improves the deposition of CHA in healing bone grafted or not with MTA.
The results of the present study indicate that laser phototherapy has a positive effect on the healing of infected wounds, particularly with the association of λ680 + λ790 nm.
The aim of the present study was to assess, by Raman spectroscopy and laser fluorescence, the repair of surgical fractures fixed with wire osteosynthesis treated or not with infrared laser (λ780 nm, 50 mW, 4 × 4 J/cm(2) =16 J/cm(2), ϕ=0.5 cm(2), CW) associated or not to the use of hydroxyapatite and guided bone regeneration. Surgical tibial fractures were created under general anesthesia on 15 rabbits that were divided into five groups, maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet, and had water ad libitum. The fractures in groups II, III, IV, and V were fixed with wires. Animals in groups III and V were grafted with hydroxyapatite (HA) and guided bone regeneration (GBR) technique used. Animals in groups IV and V were irradiated at every other day during 2 weeks (4 × 4 J/cm(2), 16 J/cm(2) =112 J/cm(2)). Observation time was that of 30 days. After animal death, specimens were taken and kept in liquid nitrogen and used for Raman spectroscopy. The Raman results showed basal readings of 1,234.38 ± 220. Groups WO+B+L showed higher readings (1,680.22 ± 822) and group WO+B the lowest (501.425 ± 328). Fluorescence data showed basal readings of 5.83333 ± 0.7. Groups WO showed higher readings (6.91667 ± 0.9) and group WO+B+L the lowest (1.66667 ± 0.5). There were significant differences between groups on both cases (p<0.05). Pearson correlation was negative and significant (R (2) = -0.60; p<0.001), and it was indicative that, when the Raman peaks of calcium hydroxyapatite (CHA) are increased, the level of fluorescence is reduced. It is concluded that the use of near-infrared lasertherapy associated to HA graft and GBR was effective in improving bone healing on fractured bones as a result of the increasing deposition of CHA measured by Raman spectroscopy and decrease of the organic components as shown by the fluorescence readings.
This paper reports the treatment of oral lymphangiomas with carbon dioxide CO₂ Laser. Lymphangiomas are rare congenital lymphatic malformations. These lesions are most frequently diagnosed during childhood, are most commonly located in the head and neck region, and are extremely rare in the oral cavity. Oral lymphangiomas are of complex treatment due to the difficulty in performing a complete excision. CO₂ laser is the most often used laser in the oral cavity due to its affinity with water and high absorption by the oral mucosa. Several benefits of the use of CO₂ laser have been reported for surgical oral procedures. The cases reported herein were biopsy-proven lymphangiomas of the oral cavity. The surgical procedures were carried out under local anesthesia and a focused CO₂ laser beam (λ10.600 nm, Φ ~2 mm, CW/RSP) was used. At the end of the surgery, the laser beam was used on a defocused mode to promote better hemostasis. Neither sutures nor dressings were used after surgery. No medication and only mouthwashes were prescribed to all patients on the postoperative period. There were no postsurgical complaints from the patients and no relapses of the conditions were observed after follow-up periods of 12 and 18 months. The use of CO₂ laser was practical, easy to carry out and effective on the treatment of oral lymphangiomas, with no lesion recurrence.
The aim of the present study was to assess, by Raman spectroscopy, the repair of surgical fractures fixed with internal rigid fixation (IRF) treated or not with IR laser (λ780 nm, 50 mW, 4 × 4 J/cm(2) = 16 J/cm(2), ϕ = 0.5 cm(2), CW) associated or not to the use of hydroxyapatite and guided bone regeneration (GBR). Surgical tibial fractures were created under general anesthesia on 15 rabbits that were divided into five groups, maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libitum. The fractures in groups II, III, IV and V were fixed with miniplates. Animals in groups III and V were grafted with hydroxyapatite and GBR technique used. Animals in groups IV and V were irradiated at every other day during 2 weeks (4 × 4 J/cm(2), 16 J/cm(2) = 112 J/cm(2)). Observation time was that of 30 days. After animal death, specimens were taken and kept in liquid nitrogen and used for Raman spectroscopy. Raman spectroscopy showed significant differences between groups (p < 0.001). Basal readings showed mean value of 1,234 ± 220.1. Group internal rigid fixation + biomaterial + laser showed higher readings (3,521 ± 2,670) and group internal rigid fixation + biomaterial the lowest (212.2 ± 119.8). In conclusion, the results of the present investigation are important clinically as spectral analysis of bone component evidenced increased levels of CHA on fractured sites by using the association of laser light to a ceramic graft.
The aim of this case report is to present a histologically diagnosed oral lichen planus excised by the CO2 laser. Oral lichen planus is a chronic inflammatory mucocutaneous disease of unknown etiology. Different treatments have been used to manage this condition. A 46 year-old female was referred to the Laser Clinic of the Dental School of the Federal University of Bahia to excise a lesion characterized by white patches on the oral mucosa, which was causing pain and burning sensation and had not respond to treatment with triamcinolone and corticosteroids for 3 months. CO2 laser was used to remove the lesion and the conclusive histopathological diagnosis was oral lichen planus. The patient was followed up over 1 year with no signs of lesion recurrence. The use of the CO2 laser was found to be useful and effective to treat lichen planus.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.