BackgroundProsthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI.MethodsPolyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20°. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation.ResultsIn all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine.ConclusionLoading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors’ observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.
Combining iron-loaded implants and MRI, we achieved mesh visualization for the first time in patients. For MRI protocol, we propose a combination of different gradient echo sequences and T2-weighted turbo spin-echo sequences: first gradient echo sequence for mesh configuration, T2wTSE for anatomy assessment, and GRE3 for evaluation of hernia coverage and mesh localization. Using our approach, MRI could become a noninvasive alternative to open surgical exploration if mesh-related complications were suspected.
In this study, significant mesh shrinkage (20.9%) but marginal changes in local mesh configuration occurred within 90 days after mesh implantation. Centroid shift of the mesh implant can be traced back to different patient positioning and abdominal distension. The developed algorithm facilitates noninvasive assessment of key figures regarding MRI-visible meshes. Consequently, it might help to improve mesh technology as well as surgical skills.
In vivo investigation of mesh surface via MRI could exclude a significant initial reduction of the effective mesh surface after release of pneumoperitoneum, in this IPOM rabbit model. A further subsequent shrinkage of these large pore PVDF meshes could be excluded, as well. Imaging of MRI-visible IPOM mesh turned out to be a sufficient tool to objectify mesh configuration and position in vivo.
In this rabbit model of iron-loaded implanted abdominal meshes, standard gradient echo imaging was best suitable to assess implant location, integrity, and configuration. In 2 of 10 animals, PCSI helped achieve a complete delineation of mesh borders.
The use of surgical textile implants (so-called "mesh") for hernia repair is an accepted standard. They may cause mesh-related problems such as chronic pain, migration or fistula formation. Nevertheless, these polymer-based textile meshes are often invisible by conventional imaging methods like computed tomography (CT) and magnetic resonance imaging (MRI). In this study we outlined the major steps in the development of a MRvisible textile implant, which can be used in patients. To achieve MR-visability, ferrooxide particles were incorporated into the base material polyvinylidene fluoride (PVDF), during the spinning process. We could proof the MR-visibility of this new textile implant in different phantoms. After clinical approval of these implants in vivo in different animal studies, we pursued to evaluate the MRconspicuity of such ferrooxide-loaded mesh implants in patients treated for inguinal hernias and explored the postsurgical mesh configuration by MRI. In this study we described the development and first results of a ferrooxide-loaded MR-visible mesh. In animal model and in clinical use such implants turned out to be a valuable tool for diagnostic and development.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.