Our current data suggest that even in the long-term course after six months and despite a higher effective surface of the PVDF samples it showed a smaller foreign body granuloma than with PP whereas the cellular response was similar.
The compression of a foil of Cu 3 Au in 4:1 methanol-ethanol and paraffin oil pressure-transmitting media has been studied by energy-dispersive x-ray diffraction in a diamond-anvil cell. Line shifts and line profiles are used to analyze elastic and plastic strains. The increasing viscosity of 4:1 methanol-ethanol causes departures from hydrostatic conditions starting around 7 GPa even while the medium is in a liquid state. The glass transitions in the range 5-7 GPa for paraffin oil and 12-13 GPa for 4:1 methanol-ethanol cause a volume incompressibility and discontinuity followed by isotropic compression behavior. The hydrostatic limit of a liquid with respect to a polycrystalline sample may lie at pressures considerably below the pressure of solidification. For nonideal powders, even small departures from nonhydrostatic conditions of the pressure transmitting medium, often termed quasihydrostatic, can have a strong influence on the compression behavior.
BackgroundProsthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI.MethodsPolyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20°. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation.ResultsIn all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine.ConclusionLoading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors’ observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.
BackgroundThe aim of this study was to analyze the early postoperative outcome of esophageal cancer treated by subtotal esophageal resection, gastric interposition and either intrathoracic or cervical anastomosis in a single center study.Methods72 patients who received either a cervical or intrathoracic anastomosis after esophageal resection for esophageal cancer were matched by age and tumor stage. Collected data from these patients were analyzed retrospectively regarding morbidity and mortality rates.ResultsAnastomotic leakage rate was significantly lower in the intrathoracic anastomosis group than in the cervical anastomosis group (4 of 36 patients (11%) vs. 11 of 36 patients (31%); p = 0.040). The hospital stay was significantly shorter in the intrathoracic anastomosis group compared to the cervical anastomosis group (14 (range 10–110) vs. 26 days (range 12 – 105); p = 0.012). Wound infection and temporary paresis of the recurrent laryngeal nerve occurred significantly more often in the cervical anastomosis group compared to the intrathoracic anastomosis group (28% vs. 0%; p = 0.002 and 11% vs. 0%; p = 0.046). The overall In-hospital mortality rate was 6% (4 of 72 patients) without any differences between the study groups.ConclusionsThe present data support the assumption that the transthoracic approach with an intrathoracic anastomosis compared to a cervical esophagogastrostomy is the safer and more beneficial procedure in patients with carcinoma of the lower and middle third of the esophagus due to a significant reduction of anastomotic leakage, wound infection, paresis of the recurrent laryngeal nerve and shorter hospital stay.
The integration of SPIOs into the base material combined with IRON is a feasible approach to visualize STI with MRI. This method could help to identify mesh-related problems in time and to reduce the need for surgical revision.
The beneficial results of mesh reinforcement in the sublay technique might be due to a superior quality of postoperative connective tissue formation. Mesh incorporation, irrespective of positioning, is favourable in low-weight, large, porous mesh material represented by a reduced inflammatory part of the foreign body granuloma.
Combining iron-loaded implants and MRI, we achieved mesh visualization for the first time in patients. For MRI protocol, we propose a combination of different gradient echo sequences and T2-weighted turbo spin-echo sequences: first gradient echo sequence for mesh configuration, T2wTSE for anatomy assessment, and GRE3 for evaluation of hernia coverage and mesh localization. Using our approach, MRI could become a noninvasive alternative to open surgical exploration if mesh-related complications were suspected.
Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift V R and Prolift 1 M V R , developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4 V R , which was designed for pelvic floor repair to withstand mechanical strain. Prolift V R at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift 1 M V R revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4 V R preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift V R and Prolift 1 M V R can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.