PURPOSE
To compare the late complications in the Ahmed Baerveldt Comparison Study during 5 years of follow-up.
DESIGN
Multicenter, prospective, randomized clinical trial.
METHODS
SETTINGS
Sixteen international clinical centers.
STUDY POPULATION
Two hundred seventy six subjects aged 18 to 85 years with previous intraocular surgery or refractory glaucoma with intraocular pressure of > 18 mmHg.
INTERVENTIONS
Ahmed Glaucoma Valve FP7 or Baerveldt Glaucoma Implant BG 101-350.
MAIN OUTCOME MEASURES
Late postoperative complications (beyond 3 months), reoperations for complications, and decreased vision from complications.
RESULTS
Late complications developed in 56 subjects (46.8 ± 4.8 5 year cumulative % ± SE) in the Ahmed Glaucoma Valve group and 67 (56.3 ± 4.7 5 year cumulative % ± SE) in the Baerveldt Glaucoma Implant group (P = 0.082). The cumulative rates of serious complications were 15.9% and 24.7% in the Ahmed Glaucoma Valve and Baerveldt Glaucoma Implant groups respectively (P = 0.034) although this was largely driven by subjects who had tube occlusions in the two groups (0.8% in the Ahmed Glaucoma Valve group and 5.7% in the Baerveldt Glaucoma Implant group, P = 0.037). Both groups had a relatively high incidence of persistent diplopia (12%) and corneal edema (20%), although half of the corneal edema cases were likely due to pre-existing causes other than the aqueous shunt. The incidence of tube erosion was 1% and 3% in the Ahmed Glaucoma Valve and Baerveldt Glaucoma Implant groups, respectively (P = 0.04).
CONCLUSIONS
Long term rates of vision threatening complications and complications resulting in reoperation were higher in the Baerveldt Glaucoma Implant than the Ahmed Glaucoma Valve group over 5 years of follow-up.
Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL) and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT) images. Methods. Two independent, masked observers (SR and AZC) identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750), and angle opening distance (AOD750) were calculated. Results. In 84% of quadrants, SR's SSL placements during 2 sessions were within 80 μm in both the X- and Y-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication) were above 0.9 for TISA750 and AOD750 for all quadrants. Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750.
Purpose. To evaluate potential risk factors for developing tube shunt exposure in glaucoma patients. Patients and Methods. Forty-one cases from 41 patients that had tube shunt exposure from 1996 to 2005 were identified from the Robert Cizik Eye Clinic and Bascom Palmer Eye Institute. Each case was matched with 2 controls of the same gender and with tube shunts implanted within 6 months of the index case. Conditional logistic regression was used to determine risk factors. Results. The study cohort includes a total of 121 eyes from 121 patients. The mean age was 63.6 ± 19.7 years, ranging from 1 to 96 years. The average time to exposure was 19.29 ± 23.75 months (range 0.36–85.74 months). Risk factors associated with tube exposure were Hispanic ethnicity (P = 0.0115; OR = 3.6; 95% CI, 1.3–9.7), neovascular glaucoma (P = 0.0064; OR = 28.5; 95% CI, 2.6–316.9), previous trabeculectomy (P = 0.0070; OR = 5.3; 95% CI, 1.6–17.7), and combined surgery (P = 0.0381; OR = 3.7; 95% CI, 1.1–12.7). Conclusions. Hispanic ethnicity, neovascular glaucoma, previous trabeculectomy, and combined surgery were identified as potential risk factors for tube shunt exposure. These potential risk factors should be considered when determining the indication for performing tube shunt implantation and the frequency of long-term followup.
Purpose. To introduce a new anterior segment optical coherence tomography parameter, trabecular-iris circumference volume (TICV), which measures the integrated volume of the peripheral angle, and establish a reference range in normal, open angle eyes. Methods. One eye of each participant with open angles and a normal anterior segment was imaged using 3D mode by the CASIA SS-1000 (Tomey, Nagoya, Japan). Trabecular-iris space area (TISA) and TICV at 500 and 750 µm were calculated. Analysis of covariance was performed to examine the effect of age and its interaction with spherical equivalent. Results. The study included 100 participants with a mean age of 50 (±15) years (range 20–79). TICV showed a normal distribution with a mean (±SD) value of 4.75 µL (±2.30) for TICV500 and a mean (±SD) value of 8.90 µL (±3.88) for TICV750. Overall, TICV showed an age-related reduction (P = 0.035). In addition, angle volume increased with increased myopia for all age groups, except for those older than 65 years. Conclusions. This study introduces a new parameter to measure peripheral angle volume, TICV, with age-adjusted normal ranges for open angle eyes. Further investigation is warranted to determine the clinical utility of this new parameter.
Timolol (generic name) is a frequently used medication for the control of glaucoma. Benzalkonium chloride (BAK) is a commonly used preservative in ophthalmic solutions with a broad range of antimicrobial activity; however, this nonspecificity can result in toxicity. Adverse effects attributed to BAK, including conjunctival inflammation and fibrosis, tear film instability, corneal cytotoxicity, anterior chamber inflammation, trabecular meshwork cell apoptosis, cataract development, macular edema, and even systemic effects, have been well documented. These effects can lead to ocular discomfort, poor intraocular pressure control, glaucoma surgery failure, and decreased patient compliance. BAK use in topical medications has decreased recently as newer and less toxic preservatives have become available. Yet these preservatives still exert some toxic effects, especially in patients with chronic eye disease who use multiple drops over extended periods of time. Thus, attempts to reduce overall preservative loads for patients are important, whether it be decreasing the amount of preservative, decreasing the total number of drops patients use, or eliminating preservatives entirely. A preservative-free formulation of timolol, TIMOPTIC® in OCUDOSE®, is available in unit-dose vials. Preservative-free unit-dose vials minimize toxic adverse effects and are a good option for patients with ocular surface disease, on long-term multidrop therapy, or who simply do not tolerate the effects of preservatives due to discomfort.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.