2014
DOI: 10.1155/2014/590978
|View full text |Cite
|
Sign up to set email alerts
|

Trabecular-Iris Circumference Volume in Open Angle Eyes Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography

Abstract: Purpose. To introduce a new anterior segment optical coherence tomography parameter, trabecular-iris circumference volume (TICV), which measures the integrated volume of the peripheral angle, and establish a reference range in normal, open angle eyes. Methods. One eye of each participant with open angles and a normal anterior segment was imaged using 3D mode by the CASIA SS-1000 (Tomey, Nagoya, Japan). Trabecular-iris space area (TISA) and TICV at 500 and 750 µm were calculated. Analysis of covariance was perf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
46
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(48 citation statements)
references
References 10 publications
(18 reference statements)
2
46
0
Order By: Relevance
“…Gonioscopy does not grade at a single axis, but as an area, which may be a clock hour or a quadrant, while with the FD ASOCT, measurement is taken in a single meridian. It might be appropriate in a future study to compare a quadrantric measurement, such as a quadrant of trabecular-iris circumference volume (TICV [5]), to gonioscopy rather than a single plane measurement. Unfortunately, that was beyond the scope of the current study as FD ASOCT measurements were taken with 2D images, which cannot be used for TICV.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Gonioscopy does not grade at a single axis, but as an area, which may be a clock hour or a quadrant, while with the FD ASOCT, measurement is taken in a single meridian. It might be appropriate in a future study to compare a quadrantric measurement, such as a quadrant of trabecular-iris circumference volume (TICV [5]), to gonioscopy rather than a single plane measurement. Unfortunately, that was beyond the scope of the current study as FD ASOCT measurements were taken with 2D images, which cannot be used for TICV.…”
Section: Discussionmentioning
confidence: 99%
“…All raw study images were exported from the FD ASOCT after data collection was complete and imported to customized software, Anterior Chamber Angle and Interpretation (ACAI, Houston, TX), as described in previous publications [35]. Two experienced FD ASOCT readers (AZC, LAB) identified scleral spur landmarks (SSLs) on superior angles (12 o'clock) and graded iris insertion using Spaeth definitions (A, B, C, D, or E).…”
Section: Participants and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Anterior segment optical coherence tomography (ASOCT) can be used to image the peripheral ACA consistently and reproducibly and quantify ACA parameters such as angle opening distance (AOD), trabecular-iris space area (TISA), and trabecular-iris circumference volume (TICV) [17, 18]. …”
Section: Introductionmentioning
confidence: 99%