Nowadays, increasing awareness of environment and fossil fuels protection stimulates intensive research on clean and renewable sources of energy. Production of hydrogen from water through solar-driven splitting reactions is one of the most promising approaches in the field of photoelectrochemistry (PEC). In this work we have fabricated well-aligned, highly-ordered, smooth-mouth TiO2 nanotube arrays (TNAs) in a two-step anodization process of titanium foil, which were then used as photoelectrodes for PEC water splitting. It demonstrates for the first time correspondence between non-linear component characteristics of multiscale rough surface and crystalline structure of annealed TNAs measured at various fabrication stages and their photoelectrochemical response. The as-anodized TNAs with isotropic surface (deduced from AFM and SEM images) and largest figure of merit (according to their PEC performance) were annealed at 450 °C in air. Scale-invariant descriptors of the surface structure of the deposits involved: fractal dimension, corner frequency, roughness, size of nanostructures and their dominant habits. Moreover, X-ray diffraction data processed using the Rietveld method confirmed co-existence of various oxides, for example: TiO2 in the form of anatase, TiO and Ti3O5 phases in the TNAs under study pointing that previous well-established mechanisms of the TNA growth were to certain degree incomplete.
Properties of the hydroxyapatite obtained by electrochemical assisted deposition (ED) are dependent on several factors including deposition temperature, electrolyte pH and concentrations, applied potential. All of these factors directly influence the morphology, stoichiometry, crystallinity, electrochemical behaviour, and particularly the coating thickness. Coating structure together with surface micro- and nano-scale topography significantly influence early stages of the implant bio-integration. The aim of this study is to analyse the effect of pH modification on the morphology, corrosion behaviour and in vitro bioactivity and in vivo biocompatibility of hydroxyapatite prepared by ED on the additively manufactured Ti64 samples. The coatings prepared in the electrolytes with pH = 6 have predominantly needle like morphology with the dimensions in the nanometric scale (~30 nm). Samples coated at pH = 6 demonstrated higher protection efficiency against the corrosive attack as compared to the ones coated at pH = 5 (~93% against 89%). The in vitro bioactivity results indicated that both coatings have a greater capacity of biomineralization, compared to the uncoated Ti64. Somehow, the coating deposited at pH = 6 exhibited good corrosion behaviour and high biomineralization ability. In vivo subcutaneous implantation of the coated samples into the white rats for up to 21 days with following histological studies showed no serious inflammatory process.
Hydroxyapatite (HAP) coatings are applied on metallic implant materials to combine mechanical properties of metallic material with bioactivity abilities of HAP ceramic. In this study, HAP coatings with additions of Si and Mg are proposed to be deposited on Ti6Al4V substrates by RF magnetron sputtering. Chemical bonding, morphology, topography and corrosion resistance in simulated body fluids (SBF) of the coatings were investigated. Additionally, mechanical and biological properties of the coatings were evaluated. It was found that the addition of Si and Mg does not influence the formation of a HAP phase. All the coatings exhibited smooth surface and uniform growth, without defects or cracks. Both hardness and elastic modulus of the coated samples decrease with Mg addition in the HAP-Si structure. Both Mg and Si addition into HAP coatings were found to enhance the corrosion resistance of the Ti6Al4V alloy in the SBF solution. Coatings with low Mg content exhibited better corrosion performance. All the coatings investigated were biocompatible, as demonstrated by SaOS-2 bone cell attachment and growth. However, cell proliferation and morphology were inferior on samples with the highest Mg content.
This work analyses the three-dimensional (3-D) surface texture of carbon-nickel (C-Ni) films grown by radio frequency (RF) magnetron co-sputtering on glass substrates. The C-Ni thin films were deposited under different deposition times, from 50 to 600 s, at room temperature. Atomic force microscopy was employed to characterize the 3-D surface texture data in connection with the statistical, and fractal analyses. It has been found that up to 180 s the sputtering occurs in more metal content mode and in greater than 180 s it occurs in more non-metal content mode.This behavior demonstrated a strong link between the structural and morphological properties of C-Ni composite films and facilitates a deeper understanding of structure/property relationships and surface defects in prepared samples. Furthermore, these findings can be applied to research on the mechanisms to prepare and control high-quality C-Ni films.carbon-nickel composite thin films, fractal analysis, RF magnetron co-sputtering, three-dimensional surface micromorphology wileyonlinelibrary.com/journal/jemt
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.