This study evaluates the seismic risk of weak first-story reinforced concrete (RC) structures retrofitted with inerter dampers at their ground level when subjected to narrow-band seismic excitations. The main advantages brought about by the ground-level inerters are the reductions in seismic demands (e.g., drifts, floor accelerations). This study shows that structures with inerters are reliable systems in terms of peak story drifts for large ground motions. For moderate ground-motion intensities, the opposite could occur, mainly for soft soil sites. The reliabilities of structures with inerter dampers at their ground level are in general higher for buildings under seismic intensities associated to limit state of incipient collapse, especially for low-height buildings. This could be reversed for intensities associated to the limit state of damage limitation. The findings of this study could guide practicing engineers to use inerter-based dampers in retrofitting ductile structures consisting of moment-resisting reinforced concrete (RC) frames subjected to narrow-band earthquake excitations in regions such as Mexico City.
RESUMENDurante algunos eventos sísmicos recientes en México, se ha observado que, a pesar de haber un adecuado comportamiento del sistema estructural, no siempre existe un adecuado comportamiento de los sistemas no estructurales. En esta investigación se llevan a cabo análisis no lineales paso a paso para estudiar el comportamiento de fachadas prefabricadas de concreto del tipo "piso a piso", las cuales han presentado fallas y desprendimientos aun cuando la estructura no ha sufrido daño. Para alcanzar este objetivo, se evalúan los desplazamientos y aceleraciones de cada uno de los pisos de un edificio de 15 niveles y 4 crujías, donde se calcula el nivel de daño de diferentes paneles. Para obtener estas respuestas, se diseña el sistema estructural mencionado utilizando el Apéndice A de las Normas Técnicas Complementarias para Diseño por Sismo del Reglamento de Construcciones del Distrito Federal del 2004 y se realiza un análisis dinámico incremental utilizando el registro sísmico del sismo de Michoacán del 19 de septiembre de 1985, obtenido en la estación de la Secretaría de Comunicaciones y Transportes. Se observa que al reducir las fuerzas sísmicas por ductilidad y sobrerresistencia, se podrían ignorar las fuerzas reales durante un sismo que son mayores a las de diseño, lo que podría provocar daño en las fachadas estudiadas.Palabras clave: fachadas prefabricadas; comportamiento sísmico; pérdida de vidas; riesgo sísmico
SEISMIC BEHAVIOR OF "FLOOR TO FLOOR" PRECAST CONCRETE FACADES ABSTRACTDuring recent earthquakes in Mexico, it has been observed that despite a proper behavior of the structure, there are failures and damage among non-structural elements. This paper presents analytical time-history analysis and results of the seismic behavior of "floor to floor" precast concrete facades. This analysis includes the evaluation of accelerations and displacements at the supports of the panels Artículo recibido el 6 de diciembre de 2017 y aprobado para su publicación el 22 de junio de 2018. Se aceptarán comentarios y/o discusiones hasta cinco meses después de su publicación.(1)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.