BackgroundThe ideal intraocular lens in cases of aphakia without capsular support is debated. Choices include anterior chamber lenses, iris- or scleral-sutured lenses, and iris-claw lenses. Our aim was to report our long-term evaluation of the use of retropupillary implantation of the Artisan iris-claw intraocular lens (RPICIOL) in several aphakic conditions without capsular support.MethodsA retrospective analysis of consecutive 320 eyes of 320 patients (222 males and 98 females) without capsular support in which we performed RPICIOL implantation in post-traumatic aphakia (141 eyes, group 1), post-cataract surgery aphakia (122 eyes, group 2), and in cases in which penetrating keratoplasty was associated with vitrectomy (57 eyes, group 3). Either anterior or posterior vitrectomy procedures were performed with 20–, 23-, or 25-gauge techniques for different associated anterior or posterior segment indications. We reviewed the refractive outcome, anatomical outcome, long-term stability of the implants, and possible long-term complications.ResultsThe mean patient age was 59.7 years (range, 16–84 years) in group 1; 60.1 years (range, 14–76 years) in group 2; and 65.8 years (range, 25–71.5 years) in group 3. The mean follow-up time was 5.3 years (range, 1 month to 8 years). At the end of the follow-up period, the mean post-operative best-corrected LogMAR visual acuity was 0.6 (range, perception of light to 0.3) in group 1; 0.3 (range, 0.5–0.1) in group 2; and 0.6 (range, hand movement to 0.2) in group 3. Disenclavation of RPICIOLs occurred in three cases because of slippage of one of the iris-claw haptics and spontaneous complete posterior dislocation occurred in one case. One case presented with retinal detachment, and no cases of uveitis were observed. Eight cases complained of chronic dull pain, and severe iridodonesis was seen in five cases. One case of post-operative macular edema was observed without post-operative increase in the mean intraocular pressure. There was no statistically different change in the endothelial cell density (cells/mm2) at the end of the follow-up period.ConclusionsRPICIOL for secondary implantations is a valid alternative strategy to scleral-fixated or angle-supported IOL implantation.
Background Though several procedures of IOL implantation have been described (sutured scleral fixation, intra-scleral fixation, angle-supported anterior chamber, and anterior chamber or retropupillary iris-claw IOLs), there are no randomized trials which are comparing different techniques. Hence, the surgical treatment of aphakia still remains controversial and challenging. The purpose of this study was to compare the long-term efficacy and the rate of complications of anterior versus posterior Iris-claw intraocular lenses (IOL) implantation to correct for the treatment of aphakia without sufficient capsule support. Methods and findings Consecutive eyes having secondary implantation of aphakic iris-fixated IOLs with a follow-up of at least 5 years were considered. Mean correct distance visual acuity (CDVA) changes, percentage of eyes with CDVA improvement, mean corneal endothelial cell density (CECD) loss and the rate of other complications were used for statistical analysis. The study evaluated a total of 180 eyes (Group A: 87 anterior chamber iris-claw fixation, Group B: 93 retropupillary iris-claw implantation) of 180 consecutive different patients, with aphakia of various reasons. CDVA improved significantly in both groups after surgery (P<0.001, ANOVA), and was remarkably higher than baseline in both groups from first week and during the entire follow-up (P<0.001, Tukey’s Honest Significant Difference). There was no statistically significant difference in CDVA between the two groups during each follow-up visits (P = NS, unpaired t-test) and in the CDVA improvement percentage between the two groups (P = 0.882, Chi-square test). No significant changes in CECD were noted after surgery in both groups (ANOVA Group A: P = 0.067, Group B: P = 0.330P). No intra-operative complications occurred in both groups. There was no statistically significant difference in the rate of complications between the two groups (P = NS, Chi-square test), except for pigment precipitates which were higher in Group A (P<0.05, Chi-square test). Conclusions Five-year follow-up shows that secondary implantation of aphakic IOLs is effective and safe for the correction treatment of aphakia in eyes without capsule support.
Remarkable improvements in optical coherence tomography (OCT) technology have resulted in highly sophisticated, noninvasive machines allowing detailed and advanced morphological evaluation of all retinal and choroidal layers. Postproduction semiautomated imaging analysis with dedicated public-domain software allows precise quantitative analysis of binarized OCT images. In this regard, the choroidal vascularity index (CVI) is emerging as a new imaging tool for the measurement and analysis of the choroidal vascular system by quantifying both luminal and stromal choroidal components. Numerous reports have been published so far regarding CVI and its potential applications in healthy eyes as well as in the evaluation and management of several chorioretinal diseases. Current literature suggests that CVI has a lesser variability and is influenced by fewer physiologic factors as compared to choroidal thickness. It can be considered a relatively stable parameter for evaluating the changes in the choroidal vasculature. In this review, the principles and the applications of this advanced imaging modality for studying and understanding the contributing role of choroid in retinal and optic nerve diseases are discussed. Potential advances that may allow the widespread adoption of this tool in the routine clinical practice are also presented.
Purpose To compare the functional and clinical outcomes of the iris-claw intraocular lens (IOL) placed on the anterior versus posterior surface of the iris. Patients and Methods A multicenter, retrospective study. Data on eyes that underwent anterior or retropupillary iris-claw IOL implantation because of inadequate capsular support secondary to complicated cataract surgery, trauma, and dislocated/opacified IOLs since January 2015 were analyzed. For study inclusion, evaluation results had to be available in the medical records both preoperatively and at 1 and 12 months after implantation. The following parameters were compared between the groups: best-corrected distance visual acuity (BCDVA), spherical and cylindrical refractive error, endothelial cell density (ECD), central macular thickness (CMT), and percentage and type of postoperative complications. Results In total, 60 eyes of 60 patients aged 73 ± 13 years were included: 28 eyes (47%) involved anterior, and 32 eyes (53%) retropupillary, iris-claw IOL fixations. Preoperatively, the groups were similar in all parameters except for a significantly higher proportion of retropupillary fixations in patients who had previously experienced a closed-globe trauma (p=0.03). The groups showed comparable improvements in BCDVA after surgery (final BCDVA: 0.34 ± 0.45 vs. 0.37 ± 0.50 logMAR in the anterior and retropupillary placement groups, respectively). During follow-up, no group difference was observed in refractive error or CMT. Both groups experienced similarly marked ECD loss and showed similar incidence of postoperative complications, with cystoid macular edema being the most common complication. Multivariable linear regression showed that BCDVA at 1 month was the best predictor of the final BCDVA. Conclusions Anterior chamber and posterior chamber iris-claw IOL fixations proved equally effective and safe for aphakic correction in eyes with inadequate capsular support.
Internal limiting membrane peeling during pars plana vitrectomy for rhegmatogenous retinal detachment significantly reduces ERM formation in the postoperative period and is associated with better visual and anatomical outcomes.
Retinal microcirculation shares similar features with cerebral small blood vessels. Thus, the retina may be considered an accessible ‘window’ to detect the microvascular damage occurring in the setting of neurodegenerative disorders. Optical coherence tomography angiography (OCT-A) is a non-invasive imaging modality providing depth resolved images of blood flow in the retina, choroid, and optic nerve. In this review, we summarize the current literature on the application of OCT-A in glaucoma and central nervous system conditions such as Alzheimer’s disease, Parkinson’s disease, and multiple sclerosis. Future directions aiming at evaluating whether OCT-A can be an additional biomarker for the early diagnosis and monitoring of neurodegenerative disorders are also discussed.
Purpose: To evaluate the optic plate and haptics of a specially designed sutureless intrascleral-fixated intraocular lens (IOL) using ultrasound biomicroscopy and anterior segment optical coherence tomography (AS-OCT). Setting: Department of Ophthalmology, San Marino Hospital, Republic of San Marino. Design: Retrospective observational case series. Methods: Eyes that underwent intrascleral fixation with IOL implantation (Carlevale) were included. Preoperative and postoperative refractive outcomes were reported. Optic plate tilt and haptics position were assessed with ultrasound biomicroscopy, whereas intrascleral plug depth and conformation were evaluated with AS-OCT. Results: The study comprised 10 aphakic eyes. Postoperative visual acuity improved in all patients. At postoperative month 3, 3 eyes (30%) had a vertical tilt of more than 100 μm, whereas no horizontal tilt was observed in any patient. The mean vertical intraocular tilt was 0.19 ± 0.22 mm. Of 20 haptics, 13 (65%) passed through the ciliary sulcus, 4 (20%) posterior to the ciliary body, and 3 (15%) through the ciliary body. AS-OCT scans showed a mean intrascleral plug depth of 247.20 ± 62.82 μm in the nasal sector and 265.50 ± 30.11 μm in the temporal sector, with adequate integration of the T-shaped plugs in the scleral tissue. Conclusions: This secondary IOL showed good intraocular stability and safe haptics fixation, making it suitable for the intrascleral fixation technique. The specific foldable design results in a low predisposition to optic plate tilt and haptic torsion. In long eyes, the sulcus-to-sulcus distance should be carefully evaluated preoperatively because the flexible structure of the IOL could be subjected to excessive stretching.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.