Surgical reduction of a small PMF with less than 25% ankle joint surface improves pressure distribution but does not affect ankle joint stability. Cite this article: 2018;100-B:95-100.
Introduction
This study investigated the effects of a small posterior malleolar fragment (PMF), containing less than 25% articular surface area, on ankle joint stability via computed tomography (CT) scanning under full weight bearing in a human cadaveric ankle fracture model.
Materials and methods
A trimalleolar fracture with a PMF of less than 25% articular surface area was created in 6 pairs of fresh-frozen human cadaveric lower legs. The specimens were randomized into 2 groups stabilized by internal fixation including a positioning screw for syndesmotic reconstruction. In Group I the PMF was addressed by direct screw osteosynthesis, whereas in Group II the fragment was not fixed. Six predefined distances within the ankle were measured under axial loading. CT scans of each specimen were performed in intact and fixated states in neutral position, dorsiflexion and plantar-flexion of the ankle.
Results
In plantar-flexion, significant differences were detected between the groups with regard to rotational instability. Group II demonstrated a significantly increased inward rotation of the fibula compared with Group I.
No significant differences were detected between the groups for each one of the measured distances in any of the three foot positions.
Conclusions
Additional reduction and fixation of a small PMF seems to neutralize rotational forces in the ankle more effectively than a sole syndesmotic screw. Clinically, this becomes relevant in certain phases of the gait cycle. Direct screw osteosynthesis of a small PMF stabilizes the ankle more effectively than a positioning screw.
End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure. Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007). These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push-out can be effectively reduced by the use of end caps.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.