Monosodium -iodoacetate (MIA)-induced animal model of osteoarthritis (OA) is under-utilised despite having many inherent advantages. At present, there is lack of studies that directly compare the degenerative changes induced by MIA with the surgical osteoarthritis induction method and human osteoarthritis, which would further verify a greater use of this model. Therefore, we compared the histological, biochemical and biomechanical characteristics in rat model using MIA against the anterior cruciate ligament transection (ACLT) and human cartilage with clinically established osteoarthritis. The right knees of Sprague-Dawley rats were subjected to either MIA or ACLT (n=18 in each group). Six rats were used as controls. Human cartilage samples were collected and compared from patients clinically diagnosed with (n=7) and without osteoarthritis (n=3). Histological, biochemical (Glycosaminoglycans/total protein) and biomechanical (cartilage stiffness) evaluations were performed at the end of the 1st and 2nd week after OA induction. For human samples, evaluations were performed at the time of sampling. Histopathological changes in the MIA group were comparable to that observed in the ACLT group and human OA. The Mankin scores of the 3 groups were comparable (MIA: 11.5±1.0; ACLT: 10.1±1.1; human OA: 13.2±0.8). Comparable reduction in Glycosaminoglycan/total protein content in the intervention groups were observed (MIA: 7±0.6; ACLT: 6.6±0.5; human OA: 3.1±0.7). Cartilage stiffness score were 24.2±15.3 Mpa for MIA, 25.3±4.8 for ACLT and 0.5±0.0 Mpa for human OA. The MIA model produces comparable degenerative changes to ACLT and human OA with the advantage of being rapid, minimally invasive and reproducible. Therefore, wider utilisation of MIA as animal translational OA model should perhaps be advocated.
Purpose: Management of Blount disease in adolescents and young adults is complex and associated with high risk of morbidities. Gradual correction with external fixator can minimize soft tissue injury and allow subsequent adjustment in degree of correction. This study investigates the surgical outcome and complication rate of gradual correction of neglected Blount disease through single-level extra-articular corticotomy. Methods: Patients treated for Blount disease using external fixator from 2002 to 2016 were recruited for the study. We used Ilizarov and Taylor Spatial Frame (TSF) external fixator to perform simultaneous correction of all the metaphyseal deformities without elevating the tibia plateau. Surgical outcome was evaluated using mechanical axis deviation (MAD), tibial femoral angle (TFA), and femoral condyle tibial shaft angle (FCTSA). Results: A total of 22 patients with 32 tibias have been recruited for the study. The mean MAD improved from 95 ± 51.4 mm to 9.0 ± 37.7 mm (medial to midpoint of the knee), mean TFA improved from 31 ± 15° varus to 2 ± 14° valgus, and mean FCTSA improved from 53 ± 14° to 86 ± 14°. Mean duration of frame application is 9.4 months. Two patients developed pathological fractures over the distracted bones, one developed delayed consolidation and other developed overcorrection. Conclusions: Correction of Blount disease can be achieved by gradual correction using Ilizarov or TSF external fixator with low risk of soft tissue complication. Longer duration of frame application should be considered to reduce the risk of pathological fracture or subsequent deformation of the corrected bone.
Taylor’s spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4 threaded rods, and 6 threaded rods were compared to a standard IEF rings with 4 threaded rods. Compression and torsional loading was performed to the frame as well as construct with Polyvinylchloride tubes. TSF rings with 4 tube connectors had the highest stiffness (3288 N/mm) while TSF rings with 6 struts was the least stiff. The situation was reversed for torsion where TSF rings with 6 oblique struts had the highest torsional stiffness (82.01 Nm/Degree) and frame Ilizarov rings with 4 threaded rods the least. Standard TSF construct of two ring with 6 oblique struts have better torsional stiffness and lower axial stiffness compared to the standard IEF.Key WordsTaylor’s Spatial Frame, Ilizarov External Fixator, Biomechanical properties
Background/ObjectiveArtificial bone models (ABMs) are used in orthopaedics for research of biomechanics, development of implants and educational purposes. Most of the commercially available ABMs approximate the morphology of Europeans, but they may not depict the Asian anatomy. Therefore, our aim was to develop the first Asian ABM of the pelvis and compare it with the existing pelvic ABM (Synbone®; Caucasian male).MethodsOne hundred clinical computed tomography (CTs) of adult pelvises (male n = 50, female n = 50) of Malay, Chinese and Indian descent were acquired. CTs were segmented and defined landmarks were placed. Three 3D statistical pelvic model and mean models (overall, male, female) were generated. Anatomical variations were analysed using principal component analysis. To measure gender-related differences and differences to the existing ABM, distances between the anterior superior iliac spines (ASIS), the anterior inferior iliac spines (AIIS), the promontory and the symphysis (conjugate vera, CV) as well as the ischial spines (diameter transversa, DT) were quantified.ResultsPrincipal component analysis displayed large variability regarding the pelvic shape and size. Female and male statistical models were similar in ASIS (225 ± 20; 227 ± 13 mm; P = 0.4153) and AIIS (185 ± 11; 187 ± 10 mm; P = 0.3982) and differed in CV (116 ± 10; 105 ± 10 mm; P < 0.0001) and DT (105 ± 7; 88 ± 8 mm; P < 0.0001). Comparing the unisex mean model with the pre-existing ABM, the ASIS (226; 275 mm; P < 0.0001), the AIIS (186; 209 mm; P < 0.0001) and the CV (111; 105 mm; P < 0.0001) differed significantly. Both models were similar regarding DT (97; 95 mm; P = 0.6927). The analysis revealed notable gender- and size-dependent anatomical variations within the Asian population. Chinese, Malay and Indian descents did not differ notably. The overall Asian model was smaller than the existing ABM.The translation potential of this articleOwing to the large differences between the Asian ABM and the pre-existing ABM, as well as differences between genders, the use of an Asian- and gender-specific ABM is important to consider in research, biomechanics and implant development for this population.
BackgroundEffective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractures in the subtrochancteric region has yet to be explored. Therefore, this comparative study was undertaken to demonstrate the merits of the LP implant in treating the subtrochancteric fracture by comparing its performance limits against those obtained with the more traditional implants; angle blade plate (ABP) and dynamic condylar screw plate (DCSP).Materials and MethodsNine standard composite femurs were acquired, divided into three groups and fixed with LP (n = 3), ABP (n = 3) and DCSP (n = 3). The fracture was modeled by a 20 mm gap created at the subtrochanteric region to experimentally study the biomechanical response of each implant under both static and dynamic axial loading paradigms. To confirm the experimental findings and to understand the critical interactions at the boundaries, the synthetic femur/implant systems were numerically analyzed by constructing hierarchical finite element models with nonlinear hyperelastic properties. The predictions from the analyses were then compared against the experimental measurements to demonstrate the validity of each numeric model, and to characterize the internal load distribution in the femur and load bearing properties of each implant.ResultsThe average measurements indicated that the constructs with ABP, DCPS and LP respectively had overall stiffness values of 70.9, 110.2 and 131.4 N/mm, and exhibited reversible deformations of 12.4, 4.9 and 4.1 mm when the applied dynamic load was 400 N and plastic deformations of 11.3, 2.4 and 1.4 mm when the load was 1000 N. The corresponding peak cyclic loads to failure were 1100, 1167 and 1600 N. The errors between the displacements measured experimentally or predicted by the nonlinear hierarchical hyperelastic model were less than 18 %. In the implanted femur heads, the principal stresses were spatially heterogeneous for ABP and DCSP but more homogenous for LP, meaning LP had lower stress concentrations.ConclusionWhen fixed with the LP implant, the synthetic femur model of the subtrochancteric fracture consistently exceeds in the key biomechanical measures of stability and durability. These capabilities suggest increased resistance to fatigue and failure, which are highly desirable features expected of functional implants and hence make the LP implant potentially a viable alternative to the conventional ABP or DCSP in the treatment of subtrochancteric femur fractures for the betterment of clinical outcome.
We describe an unusual case of osteosarcoma in a Jehovah's Witness patient who underwent chemotherapy and major surgery without the need for blood transfusion. This 16-year-old girl presented with osteosarcoma of the right proximal tibia requiring proximal tibia resection, followed by endoprosthesis replacement. She was successfully treated with neoadjuvant chemotherapy and surgery with the support of haematinics, granulocyte colony-stimulating factor, recombinant erythropoietin and intraoperative normovolaemic haemodilution. This case illustrates the importance of maintaining effective, open communication and exploring acceptable therapeutic alternative in the management of these patients, whilst still respecting their beliefs.
Background. Periacetabular resections with reconstruction has high rates of complications due to the complexity of the reconstruction. We have improvised a novel technique of reconstruction for type II and type II + III pelvic resections with the use of a commercially available acetabulum reconstruction cage (gap II, Stryker) and threaded rods. Objectives. The aim of our study is to determine the biomechanical strength of our reconstruction compared to the traditional cemented total hip replacement (THR) designs in normal acetabulum and establish its mode of failure. Methods. Five sets of hemipelvises were biomechanically tested (Instron® 3848, MA, USA). These constructs were subjected to cyclic loading and load to failure. Results. The reconstructed acetabulum was stiffer and required a higher load to failure compared to the intact pelvis with a standard THR. The mean stiffness of the reconstructed pelvis was 1738.6 ± 200.3 Nmm−1 compared to the intact pelvis, which was 911.4 ± 172.7 Nmm−1 (P value = 0.01). The mean load to failure for the standard acetabular cup construct was 3297.3 ± 117.7 N while that of the reconstructed pelvis with the acetabulum cage and threaded rods was 4863.8 ± 7.0 N. Conclusion. Reconstruction of the pelvis with an acetabular reconstruction cage and threaded rods is a biomechanical viable option.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.