This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
The CRP response varied according to the degree of surgical trauma on 3 standardized levels, thus supporting the use of canine serum concentrations of CRP as an inflammatory activity indicator and monitoring marker.
For oral glucose tolerance test (OGTT) in mice, multiple blood samples need to be taken within a few hours from conscious mice. Today, a number of essential parameters may be analysed on very small amounts of plasma, thus reducing the number of animals to be used. It is, however, crucial to obtain high-quality plasma or serum in order to avoid increased data variation and thereby increased group sizes. The aim of this study was to find the most valid and reproducible method for withdrawal of blood samples when performing OGTT. Four methods, i.e. amputation of the tail tip, lateral tail incision, puncture of the tail tip and periorbital puncture, were selected for testing at 218C and 308C after a pilot study. For each method, four blood samples were drawn from C57BL/6 mice at 30 min intervals. The presence of clots was registered, haemolysis was monitored spectrophotometrically at 430 nm, and it was noted whether it was possible to achieve 30-50 mL blood. Furthermore, a small amount of extra blood was sampled before and after the four samplings for testing of whether the sampling induced a blood glucose change over the 90 min test period. All methods resulted in acceptable amounts of plasma. Clots were observed in a sparse number of samples with no significant differences between the methods. Periorbital puncture did not lead to any haemolysed samples at all, and lateral tail incision resulted in only a few haemolysed samples, while puncture or amputation of the tail tip induced haemolysis in a significant number of samples. All methods, except for puncture of the tail tip, influenced blood glucose. Periorbital puncture resulted in a dramatic increase in blood glucose of up to 3.5 mmol/L indicating that it is stressful. Although lateral tail incision also had some impact on blood glucose, it seems to be the method of choice for OGTT, as it is likely to produce a clot-free non-haemolysed sample, while periorbital sampling, although producing a high quality of sample, induces such a dramatic change in blood glucose that it should not be applied for OGTT in mice.
Blood collection in mice can be a challenge, in particular for samples used for coagulation analysis as initiation of coagulation during the procedures can influence the results. Blood collection from the retrobulbar venous plexus is commonly used but the method remains controversial. Several alternatives exist but not all are applicable to mice with a compromised coagulation system because of subsequently excessive bleeding. We therefore wanted to explore whether blood collection by puncture of the submandibular vein could replace blood collected from the retrobulbar venous plexus during pharmacokinetic and pharmacodynamic studies in mice lacking coagulation factor VIII (FVIII). The plasma concentrations of recombinant activated factor VII were independent of the blood collection method in a pharmacokinetic study. The same applied to the thromboelastographic profile of mice with normal coagulation in a pharmacodynamic study. However, excessive haemorrhages were observed in all FVIII knockout mice after a single puncture of the submandibular vein and 60% of the mice were euthanized 2-4 h after the blood collection. In contrast, no or only slight haemorrhage was observed in animals subjected to blood collection from the retrobulbar venous plexus. No signs of distress determined by blood glucose level or clinical abnormalities of the eye were observed after puncture of the retrobulbar venous plexus. In conclusion, blood collected by puncture of the submandibular vein and retrobulbar venous plexus has a quality which allows it to be used in coagulation assays. However, because of excessive bleedings, puncture of the submandibular vein is not recommended in mice lacking FVIII.
This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.