We propose a new low-coherence interferometry system for dual-wavelength off-axis digital holography. By utilizing diffraction gratings, two beams with narrower bandwidths and different center wavelengths could be filtered in a single light-emitting diode. The characteristics of the system are analytically determined to extend the coherence length and field-of-view enough for off-axis configuration. The proposed system enables the fast and accurate measurement of the surface profile with more than a micrometer step height and less noise. The performance of the system is verified by the experimental results of a standard height sample.
Plasmonic lithography has been used in nanofabrication because of its utility beyond the diffraction limit. The resolution of plasmonic lithography depends on the nano-gap between the nanoaperture and the photoresist surface—changing the gap distance can modulate the line-width of the pattern. In this letter, we demonstrate solid-immersion lens based active non-contact plasmonic lithography, applying a range of gap conditions to modulate the line-width of the pattern. Using a solid-immersion lens-based near-field control system, the nano-gap between the exit surface of the nanoaperture and the media can be actively modulated and maintained to within a few nanometers. The line-widths of the recorded patterns using 15- and 5-nm gaps were 47 and 19.5 nm, respectively, which matched closely the calculated full-width at half-maximum. From these results, we conclude that changing the nano-gap within a solid-immersion lens-based plasmonic head results in varying line-width patterns.
The feasibility of stimulated emission depletion (STED) microscopy using a solid immersion lens was investigated. First, the theoretical feasibility of the considered system is discussed based on a vectorial field algorithm that uses a stratified medium composed of a SIL air-gap and test sample. Using the simulation, we verified that evanescent waves with much higher spatial frequencies corresponding to the high numerical aperture in the air-gap can be utilized to achieve a higher resolution than a confocal fluorescent image without a depletion beam. The simulated expectation was supported by actual imaging on two types of samples: fluorescent beads with a 20 nm diameter and an actin sample with a filamentous structure. The lateral resolution of the system was determined to be 34 nm via the imaging results on the nano-beads. The system was quite promising for achieving nano-scale surface imaging of biological samples; an even higher resolution was achieved by adjusting the wavelength and the intensity of the depletion beam.
We report on the realization of solid immersion lens (SIL)-based near-field (NF) optics with an annular aperture, which is targeted to achieve high optical resolution. A numerical aperture (NA) = 1.84 hemisphere SIL-optics with an annular aperture achieves higher optical resolution than the conventional NA = 2.0 SIL-optics. The designed aperture is fabricated by photo-lithography and dry-etching technique. Experimental verification of the designed optics was performed through beam spot profile measurement under NF imaging conditions. A 15% smaller full-width-at-half-maximum spot diameter is obtained by the aperture. We verified that this method gives an improvement of the resolution in the optical imaging systems requiring higher resolution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.