A model to support decision systems regarding the quantification, location and opening adjustment of control valves in a network system, with the main objective to minimise pressures and consequently leakage levels is developed. This research work aims at a solution that allows simultaneously optimising the number of valves and its location, as well as valves opening adjustments for simulation in an extended period, dependently of the system characteristics. EPANET model is used for hydraulic network analysis and two operational models are developed based on the Genetic Algorithm optimisation method for pressure control, and consequently leakage reduction, since a leak is a pressure dependent function. In these two modules, this method has guaranteed an adequate technique performance, which demands a global evaluation of the system for different scenarios. A case study is presented to show the efficiency of the system by pressure control through valves management.
Pump operating as turbine (PAT) is an effective source of reducing the equipment cost in small hydropower plants. However, the manufacturers provide poor information on the PAT performance thus representing a limit for its wider diffusion. Additional implementation difficulties arise under variable operating conditions, characteristic of water distribution networks (WDNs). WDNs allow to obtain widespread and globally significant amount of produced energy by exploiting the head drop due to the network pressure control strategy for leak reductions. Thus a design procedure is proposed that couples a parallel hydraulic circuit with an overall plant efficiency criteria for the market pump selection within a WDN. The proposed design method allows to identify the performance curves of the PAT that maximizes the produced energy for an assigned flow and pressure-head distribution pattern. Finally, computational fluid dynamics (CFD) is shown as a suitable alternative for performance curve assessment covering the limited number of experimental data.
In the management of water distribution networks, large energy savings can be yielded by exploiting the head drop due to the network pressure control strategy, i.e., for leak reductions. Hydropower in small streams is already exploited, but technical solutions combining efficiency and economic convenience are still required. In water distribution networks, an additional design problem comes out from the necessity of ensuring a required head drop under variable operating conditions, i.e., head and discharge variations. Both a hydraulic regulation (HR)-via a series-parallel hydraulic circuit-and an electrical regulation (ER)-via inverter-are feasible solutions. A design procedure for the selection of a production device in a series-parallel hydraulic circuit has been recently proposed. The procedure, named VOS (Variable Operating Strategy), is based on the overall plant efficiency criteria and is applied to a water distribution network where a PAT (pump as a turbine) is used in order to produce energy. In the present paper the VOS design procedure has been extended to the electrical regulation and a comparison between HR and ER efficiency and flexibility within a water distribution network is shown: HR was found more flexible than ER and more efficient. Finally a preliminary economic study has been carried out in order to show the viability of both systems, and a shorter payback period of the electromechanical equipment was found for HR mode.
Analyses of possible synergies between energy recovery and water management are essential for achieving sustainable improvements in the performance of irrigation water networks. Improving the energy efficiency of water systems by hydraulic energy recovery is becoming an inevitable trend for energy conservation, emissions reduction, and the increase of profit margins as well as for environmental requirements. This paper presents the state of the art of hydraulic energy generation in drinking and irrigation water networks through an extensive review and by analyzing the types of machinery installed, economic and environmental implications of large and small hydropower systems, and how hydropower can be applied in water distribution networks (drinking and irrigation) where energy recovery is not the main objective. Several proposed solutions of energy recovery by using hydraulic machines increase the added value of irrigation water networks, which is an open field that needs to be explored in the near future.Keywords: irrigation water networks; water-energy nexus; renewable energy; sustainability and efficiency; hydropower solutions; water management Hydropower GenerationSociety's energy consumption worldwide has increased by up to 600% over the last century. This increase has been a direct result of population growth since the industrial revolution, in which energy has been provided mainly by fossil fuels. Nevertheless, today and in the near future, renewable energies are expected to be more widely implemented to help maintain sustainable growth and quality of life and, by 2040, to reduce energy consumption down to the 2010 levels [1].Sustainability must be achieved by using strategies that do not increase the overall carbon footprint, considering all levels of production (macro-and microscale) of the different supplies. These strategies' development has to be univocally linked to new technologies [2]. Special attention must be paid to those new strategies that are related to energy recovery. These new techniques have raised interesting environmental and economic advantages. Therefore, a deep knowledge of the water-energy nexus is crucial for quantifying the potential for energy recovery in any water system [3], and defining performance indicators to evaluate the potential level of energy savings is a key issue for sustainability, environmental, or even management solutions [4].Energy recovery, with the aim of harnessing the power dissipated by valves (in pressurized flow) or hydraulic jumps (in open channels), is becoming of paramount importance in water distribution
The current paper focuses on leakage detection in pipe systems by means of the standing wave difference method ͑SWDM͒ used for cable fault location in electrical engineering. This method is based on the generation of a steady-oscillatory flow in a pipe system, by the sinusoidal maneuver of a valve, and the analysis of the frequency response of the system for a certain range of oscillatory frequencies. The SWDM is applied to several configurations of pipe systems with different leak locations and sizes. A leak creates a resonance effect in the pressure signal with a secondary superimposed standing wave. The pressure measurement and the spectral analysis of the maximum pressure amplitude at the excitation site enable the identification of the leak frequencies and, consequently, the estimation of the leak approximate location. Practical difficulties of implementation of this technique in real life systems are discussed.
Pressure control is one of the main techniques to control leakages in Water Distribution Networks (WDNs) and to prevent pipe damage, improving the delivery standards of a water supply systems. Pressure reducing stations (PRSs) equipped by either pressure reducing valves or motor driven regulating valves are commonly used to dissipate excess hydraulic head in WDNs. An integrated new technical solution with economic and system flexibility benefits is presented which replaces PRSs with pumps used as turbines (PATs). Optimal PAT performance is obtained by a Variable Operating Strategy (VOS), recently developed for the design of small hydropower plants on the basis of valve time operation, and net return determined by both energy production and savings through minimizing leakage. The literature values of both leakages costs and energy tariffs are used to develop a buisness plan model and evaluate the economic benefit of small hydropower plants equipped with PATs. The study shows that the hydropower installation produces interesting economic benefits, even in presence of small available power, that could encourage the leakage reduction even if water savings are not economically relevant, with consequent environmental benefits.
Abstract:The emptying procedure is a common operation that engineers have to face in pipelines. This generates subatmospheric pressure caused by the expansion of air pockets, which can produce the collapse of the system depending on the conditions of the installation. To avoid this problem, engineers have to install air valves in pipelines. However, if air valves are not adequately designed, then the risk in pipelines continues. In this research, a mathematical model is developed to simulate an emptying process in pipelines that can be used for planning this type of operation. The one-dimensional proposed model analyzes the water phase propagation by a new rigid model and the air pockets effect using thermodynamic formulations. The proposed model is validated through measurements of the air pocket absolute pressure, the water velocity and the length of the emptying columns in an experimental facility. Results show that the proposed model can accurately predict the hydraulic characteristic variables.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers