Background. Understanding the total cavopulmonary connection (TCPC) hemodynamics may lead to improved surgical procedures which result in a more efficient modified circulation. Reduced energy loss will translate to less work for the single ventricle and although uni ventricular physiology is complex, this improvement could contribute to improved postoperative outcomes. Therefore to conserve energy, one surgical goal is opti mization of the TCPC geometry. In line with this goal, this study investigated whether addition of caval curva ture or flaring at the connection conserves energy.Methods. TCPC models were made varying the curva ture of the caval inlet or by flaring the anastomosis. Steady flow pressure measurements were made to calcu late the power loss attributed to each connection design over a range of pulmonary flow splits (70:30 to 30:70). Particle flow visualization was performed for each design and was qualitatively compared to the power losses.Results. Results indicate that curving the cavae toward
QGS and ECTb values of cardiac function computed from 8-frame gated perfusion SPECT correlate very well with each other and correlate well with MR. Averaged over all subjects, ECTb measurements of EF are not significantly different from MR values but QGS significantly underestimates the MR values.
Evaluating the in vivo accuracy of magnetic resonance phase velocity mapping (PVM) is not straightforward because of the absence of a validated clinical flow quantification
Although several methods have been used clinically to assess aortic regurgitation (AR), there is no “gold standard” for regurgitant volume measurement. Magnetic resonance phase velocity mapping (PVM) can be used for noninvasive blood flow measurements. To evaluate the accuracy of PVM in quantifying AR with a single imaging slice in the ascending aorta, in vitro experiments were performed by using a compliant aortic model. Attention was focused on determining the slice location that provided the best results. The most accurate measurements were taken between the aortic valve annulus and the coronary ostia where the measured (Y) and actual (X) flow rate had close agreement (Y = 0.954 × + 0.126, r2 = 0.995, standard deviation of error = 0.139 L/min). Beyond the coronary ostia, coronary flow and aortic compliance negatively affected the accuracy of the measurements. In vivo measurements taken on patients with AR showed the same tendency with the in vitro results. In making decisions regarding patient treatment, diagnostic accuracy is very important. The results from this study suggest that higher accuracy is achieved by placing the slice between the aortic valve and the coronary ostia and that this is the region where attention should be focused for further clinical investigation.
Reliable diagnosis and quantification of mitral regurgitation are important for patient management and for optimizing the time for surgery. Previous methods have often provided suboptimal results. The aim of this in vitro study was to evaluate MR phase‐velocity mapping in quantifying the mitral regurgitant volume (MRV) using a control volume (CV) method. A number of contiguous slices were acquired with all three velocity components measured. A CV was then selected, encompassing the regurgitant orifice. Mass conservation dictates that the net inflow into the CV should be equal to the regurgitant flow. Results showed that a CV, the boundary voxels of which excluded the region of flow acceleration and aliasing at the orifice, provided accurate measurements of the regurgitant flow. A smaller CV provided erroneous results because of flow acceleration and velocity aliasing close to the orifice. A large CV generally provided inaccurate results because of reduced velocity sensitivity far from the orifice. Aortic outflow, orifice shape, and valve geometry did not affect the accuracy of the CV measurements. The CV method is a promising approach to the problem of quantification of the MRV.
Mechanical fragility of red blood cells (RBCs) is a critical variable for the hemolysis testing of many important clinical devices, such as pumps, valves, and cannulae, and gas exchange devices. Unfortunately, no standardized test for RBC mechanical fragility is currently well accepted. Although many test devices have been proposed for the study of mechanical fragility of RBCs, no one has ever shown that their results have any relevance to a blood pump. Therefore, the fundamental objective of this study was to determine if one or more test devices could be validated as calibrators to document the fragility of the test blood used for any particular test blood. We compared five mechanical fragility test systems to each other and to a Biopump, with respect to hemolysis. All five devices seem to measure the same parameter; the hemoresistometer most closely matched the pump test results, but the stainless steel bead test may be the most practical for routine calibration purposes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.