The NycoCard D-dimer test card required no specialised equipment and could therefore facilitate rapid screening for thromboembolic disease/disseminated intravascular coagulation in first opinion practice. Elevations in D-dimer concentration can be found in a number of clinical conditions apart from thromboembolic disease/disseminated intravascular coagulation and should not therefore be used as the sole basis of diagnosis. D-dimer may be considered a good screening test for thromboembolic disease/disseminated intravascular coagulation as only one case with histopathological evidence of thromboembolic disease/disseminated intravascular coagulation had a D-dimer concentration in the range seen in healthy dogs.
The VetScan HMT is an impedance counter haematology analyser which produces a full blood count and three-part white blood cell differential. The aim of this study was to compare the results generated by the analyser with those obtained by standard methods used routinely in the authors' laboratory. Blood samples from 68 dogs and 59 cats were run on the VetScan HMT analyser and also subjected to reference methods, and the results obtained were compared. Correlation coefficients (feline/canine) were: 0.97/0.99 for haematocrit (Hct), 0.98/0.99 for haemoglobin (Hb), 0.81/0.98 for total white blood cells (WBC), and 0.89/0.97 for granulocyte and 0.65/0.93 for platelet counts. Coefficients for lymphocyte counts were 0.25/0.28 and for monocyte counts were 0.12/0.79. In conclusion, the VetScan HMT performed well on canine samples, showing excellent correlation for canine Hct, Hb, RBC, WBC, granulocyte and platelet counts. For feline samples, although there was excellent correlation for Hct, Hb and RBC, the WBC and three-part white blood cell differential and platelet count should be interpreted with caution as they can be unreliable.
Storage of citrated whole blood at room temperature for 24 or 48 hours did not significantly alter the measurement of prothrombin time but resulted in significantly shorter activated partial thromboplastin time results. Extrapolating from these findings, it is proposed that unseparated clinical samples that are submitted to an external diagnostic laboratory for the performance of clotting times, may generate reliable prothrombin time but unreliable activated partial thromboplastin time results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.