The aim of this study was to compare blood copy, haematological and glucose values between cats experimentally infected with either Mycoplasma haemofelis (Group HF: 10 cats), ‘Candidatus M. haemominutum’ (Group HM: 3 cats) or ‘Candidatus M. turicensis’ (Group TU: 3 cats). Blood samples were collected regularly up to 85 days post-infection (DPI) for haemoplasma real-time quantitative PCR, haematology, Coombs’ testing and blood glucose measurement. Statistical analysis was performed using a general linear model (ANOVA) appropriate for a repeated measures experiment with significance set as P < 0.05. Cats in Group TU had significantly lower blood copy numbers than cats in Group HF (P < 0.001) and HM (P < 0.001). All Group HF cats developed anaemia (often severe), macrocytosis and evidence of erythrocyte-bound antibodies whereas Groups HM and TU cats did not. Group HF had significantly lower PCVs, haemoglobin concentrations and red blood cell counts, and significantly higher mean cell volumes, than Groups HM and TU. In Group HF, erythrocyte-bound antibodies reactive at 4 °C (both IgM and IgG) appeared between 8 and 22 DPI and persisted for two to four weeks, whereas those reactive at 37 °C (primarily IgG) appeared between 22 and 29 DPI and persisted for one to five weeks. In most cats antibodies appeared after the fall in haemoglobin started. Although Group TU had significantly lower glucose concentrations than Groups HF (P = 0.006) and HM (P = 0.027), mean blood glucose concentrations remained within the reference range in all groups. This study demonstrates that M. haemofelis infection, in contrast to ‘Candidatus M. haemominutum’ and ‘Candidatus M. turicensis’ infection, can result in a severe macrocytic anaemia and the development of cold and warm reactive erythrocyte-bound antibodies.
Although use of a 100-cell (vs 200-cell) M-diff% may be a limitation of our study, good correlation between WBC differentials obtained using the LaserCyte and the manual method was achieved only for feline eosinophils.
The NycoCard D-dimer test card required no specialised equipment and could therefore facilitate rapid screening for thromboembolic disease/disseminated intravascular coagulation in first opinion practice. Elevations in D-dimer concentration can be found in a number of clinical conditions apart from thromboembolic disease/disseminated intravascular coagulation and should not therefore be used as the sole basis of diagnosis. D-dimer may be considered a good screening test for thromboembolic disease/disseminated intravascular coagulation as only one case with histopathological evidence of thromboembolic disease/disseminated intravascular coagulation had a D-dimer concentration in the range seen in healthy dogs.
The VetScan HMT is an impedance counter haematology analyser which produces a full blood count and three-part white blood cell differential. The aim of this study was to compare the results generated by the analyser with those obtained by standard methods used routinely in the authors' laboratory. Blood samples from 68 dogs and 59 cats were run on the VetScan HMT analyser and also subjected to reference methods, and the results obtained were compared. Correlation coefficients (feline/canine) were: 0.97/0.99 for haematocrit (Hct), 0.98/0.99 for haemoglobin (Hb), 0.81/0.98 for total white blood cells (WBC), and 0.89/0.97 for granulocyte and 0.65/0.93 for platelet counts. Coefficients for lymphocyte counts were 0.25/0.28 and for monocyte counts were 0.12/0.79. In conclusion, the VetScan HMT performed well on canine samples, showing excellent correlation for canine Hct, Hb, RBC, WBC, granulocyte and platelet counts. For feline samples, although there was excellent correlation for Hct, Hb and RBC, the WBC and three-part white blood cell differential and platelet count should be interpreted with caution as they can be unreliable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.